Vermont Castings Radiance RUVS40 Скачать руководство пользователя страница 22

22

Vermont Castings Radiance

21.

Wire Clip

1208618

22.

Wire Tie,
Wire Harness/Rear Shroud

1201504

23.

Wire Harness,
Burner / Thermostat

1601913

24.

Wire Harness,
Snapstat Extension (not shown)

30000453

25.

Gas Log Set

20000853

26.

Back Log

20000856

27.

Right Middle Log

20000854

28.

Left Middle Log

20000855

29.

Top Log

30000037

30.

Left Front Ember Log

20000880

31.

Right Front Ember Log

20000881

32.

Lava Rocks

57897

33.

Burner Assembly

30000446

34.

Manifold Tube Assembly

20000663

35.

Orifice Hood, Front - NG (#51)

30000449

Orifice Hood, Front - LP (#60)

30000518

36.

Orifice Hood, Rear - NG (#42)

30000332

Orifice Hood, Rear - LP (#54)

20000130

37.

Pilot, ODS w/TP-OP #84210 - NG

1601929

Pilot, ODS w/TP-OP #84210 - LP

1601930

38.

Valve Bracket

1409110

39.

Control Valve, Honeywell 8421
NG

10000235

LP

1000-0242

40.

Ignition Cable

20000101

41.

Pilot Bracket

20000851

42.

Pilot Tubing

30000448

43.

Firebox

1301148

44.

Bottom

30000328

45.

Control Panel

1409136

46.

Front

1301229

47.

Cable, Control Door

1601924

48.

Spring, Control Door

1201842

49.

Control Door

1301220

50.

Control Door Handle, Wood

1600660

Handle Stub

1601981

51.

Damper Tab (8)

1601488

52.

1/4-20 x 3/8" Phillips Screw (13)

1200993

53.

1/4-20 x 1/2" Hex Head Screw (10)

1201338

54.

1/4-20 x 1

¹⁄₄

" Stud, Top Plate (4)

1204212

55.

Flat Washer, 1/4", 7/8 O.D. (12)

1202470

56.

1/4-20 x Hex nut, Top to Sides (5)

1203210

57.

Flat Washer, 1/4" Blk (5)

1202473

58.

1/4-20 x 1" Leg Levelling Bolt (4)

1201745

59.

#10 x 1/2" Pan Hd
Sheet Metal Screw (39)

1202058

60.

8-32 x 2" Rnd Hd Slotted Screw(1)

1201243

61.

#10-24 X 1/4" Phil. Pn Hd Screw (4)

120 0980

Item/Model Number

Part Number

RUVS40

 

(Continued)

Item/Model Number

Part Number

For replacement parts, or for information about parts or
service, contact your local Vermont Castings, Majestic
Products Company Authorized Dealer. For the name of
the dealer nearest you, call or write:

The Vermont Castings,
Majestic Products Company
410 Admiral Blvd.
Mississauga, Ontario, Canada L5T 2N6
905 670-7885

Fig. 37  RUVS40 Wiring Diagram

ON

BLACK

RED

RED

WHITE

WHITE

TAN

THERMOSTAT

(OPTIONAL)

THERMOPILE

SIT

Gas Valve

TP/TH

TP

TH

OFF

 T'ST

A

T

Label

ST204

Содержание Radiance RUVS40

Страница 1: ...mbustion and ventilation air must be provided Radiance Vent Free Gas Heater Model RUVS40 3000 0456c 1000 INSTALLER CONSUMER SAFETY INFORMATION WARNING If the information in this manual is not followed...

Страница 2: ...ontact your hearth products dealer or local gas supplier for the name of a qualified service person INSTALLER Please read this manual carefully before you begin the installation procedures Failure to...

Страница 3: ...ket manufactured mobile home where not prohibited by state or local codes This appliance is to be used only with the type of gas specified on the rating plate which is attached to the rear panel This...

Страница 4: ...ore fresh air If heater keeps shutting off see Troubleshooting page 17 9 DO NOT operate this heater where flammable liquids or vapors are used or stored under dusty conditions 10 The heater becomes ve...

Страница 5: ...gas flow to the burner in the event that sufficient fresh air becomes unavailable for continued safe operation Quick Installation Your Radiance Vent Free heater is shipped completely assembled and re...

Страница 6: ...caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing elec...

Страница 7: ...f the two grilles must provide an opening of at least 50 square inches with all opening dimensions being at least 3 One grille must be located within 12 of the ceiling the other within 12 of the floor...

Страница 8: ...air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacc...

Страница 9: ...the help of an assistant carefully remove the stove from the pallet and move it close to its final installed position Lift the stove by the sides Do not lift by any part of the stove front Hardware Ba...

Страница 10: ...shroud to the side of the stove Remove the sheet metal screw C that fastens the switchbox to the rear shroud Remove the two sheet metal screws D that secure the inner and outer shroud together Let th...

Страница 11: ...snapstat Fig 13 Looking through the stove front locate the snapstat mounting screws on the side of the left air duct under the top plate Remove the front screw A but only loosen the rear screw Slip t...

Страница 12: ...ness These wires are accessible from under the left rear side of the stove Either thermostat wire may connected to either terminal Fig 16 3 Place the control switch on the rear of the stove in the T S...

Страница 13: ...the rear There should be a gap of about 13 16 between the front of the burner and the inside front wall of the firebox Place the two front ember log sections 4 and 5 Fig 21 in the slot at the front o...

Страница 14: ...orners engage notches at the top forward corners of the stove sides Then gently swing the bottom of the front panel to a vertical position and lower it till prongs on its bottom left and right corners...

Страница 15: ...h new logs paint and metal being heated Odors should dissipate within a few hours or so however you can open a window to provide plenty of fresh air to alleviate this condition Pilot and Burner Inspec...

Страница 16: ...ESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE TO TURN OFF GAS TO APPLIANCE A This appliance has a pilot When lighting the pilot follow...

Страница 17: ...is can be caused by a Incorrect gas pressure and or b other conditions that should be identified only by a qualified service technician 7 Thermocouple is damaged 8 Control Valve is damaged Solution 1...

Страница 18: ...ion NG 5 W C 8 W C 5 W C 7 W C at elevations over 8000 ft LP 11 W C 12 W C Warning If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use...

Страница 19: ...DO NOT OPERATE THE HEATER WITH A DAMAGED OR LOOSE LOG SET Use a soft bristled brush vacuum cleaner attach ment to remove dust or debris from the log set pilot and burner Use care as the log set is fr...

Страница 20: ...slowly pour it into the water mixing thoroughly 4 Place the combustor into the solution and allow to soak for fifteen 15 minutes If the module is not completely covered follow steps 1 3 to prepare en...

Страница 21: ...ake changes in design materials specifications prices and discontinue colors and products at any time without notice 0456 1 Grille 1301192 2 Grille Screen 1601933 3 Top 1301186 4 End Left 1301234 5 En...

Страница 22: ...1229 47 Cable Control Door 1601924 48 Spring Control Door 1201842 49 Control Door 1301220 50 Control Door Handle Wood 1600660 Handle Stub 1601981 51 Damper Tab 8 1601488 52 1 4 20 x 3 8 Phillips Screw...

Страница 23: ...pection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer for parts and or labor Any Radiance Natural Vent Room Heater or part thereof tha...

Страница 24: ...s Radiance The Vermont Castings Majestic Products Company 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7885 www majesticproducts com www vermontcastings com The Vermont Castings Majesti...

Отзывы: