CONDITIONS OF INSTALLATION
It is the law that all gas appliances are installed only by a competent (e.g. CORGI
Registered) Installer, in accordance with the installation instructions and the Gas Safety
(Installation and Use) Regulations 1994 with the rules in force. Failure to install
appliances correctly could lead to prosecution. It is in your own interest and that of safety
to comply with the law.
The stove may be fitted below a combustible shelf providing that the shelf is at least
610mm above the top of the stove, the shelf must not extend in front of the stove. For a
combustible side surface a minimum distance of 305mm is required, combustible rear
surface 305mm and any rear surface 100mm.
No additional purpose made additional ventilation is normally required for this appliance in
G.B.
If the chimney or flue has been previously used by appliances burning fuels other than
gas, they must be swept prior to the installation of this stove.
NB. For appliances installed in Republic of Ireland, refer to Domestic Gas Installation
document for specific ventilation requirements.
The Model number of this appliance is V 10;V10-3;V12;V12-3 and it is manufactured by: -
The rating plate is located on the control panel on the underside of the appliance