background image

Vermont Castings  •  Dauntless FlexBurn Installation Manual_R8  •  2020 - ___ •  11/21

3

3-90-586000i

A. Appliance Certification

MODEL:

Dauntless FlexBurn

®

 Wood Stove

LABORATORY:

Tested and Listed by OMNI Test 

Laboratories, Inc

REPORT NO.

0061WS104E, 0061WS104S

TYPE:

Solid Fuel Type Room Heaters

STANDARD(s):

ASTM E2515, ASTM E3053,

UL-1482 (R2015), ULC-S627-00, B415.1

Fire Risk.

Hearth  &  Home Technologies  disclaims  any 

responsibility for, and the warranty will be voided 

by, the following actions:

WARNING

!

•  Installation and use of any damaged appliance.
•  Modification of the appliance.
•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation  and/or  use  of  any  component  part  not 

approved by Hearth & Home Technologies.

•  Operating  appliance  without  fully  assembling  all 

components.

•  Operating appliance without legs attached (if supplied 

with it).

•  Do NOT Over fire - If appliance or chimney connector 

glows, you are over firing.

 Any such action that may cause a fire hazard.

Product Listing and Important Safety Information 

B. BTU & Efficiency Specifications

The Vermont Castings Dauntless FlexBurn

®

 

Wood Appliance meets the U.S. Environmental 

Protection Agency Certified to comply with the 

2020 particulate emission standards using 

cord wood.

EPA Report #:

 240-19 (

without catalyst

)

 246-19 (

catalytic

)

EPA Certified Emissions:

1.1 g/hr 

(without catalyst)

1.2 g/hr 

(catalytic)

*LHV Tested Efficiency:

81.6% 

(without catalyst)

82.6% 

(catalytic)

**HHV Tested Efficiency:

76.9% 

(without catalyst)

77.9% 

(catalytic)

***EPA BTU Output:

12,250 - 49,430

(without catalyst)

14,520 - 41,940

(catalytic)

****Peak BTU/Hour Output:

45,500

Vent Size:

6 Inch (152 mm)

Firebox Size:

1.8 cu. ft.

Outside Air Size:

3 Inch

Recommended Length:

16 Inch

Max. Wood Length:

18 Inch

Fuel Orientation:

East, West

Fuel

Seasoned Cordwood 

(20% moisture or less)

*Weighted  average  LHV  efficiency  using  Douglas  Fir 

dimensional  lumber  and  data  collected  during  EPA 

emissions test.

**

Weighted  average  HHV  efficiency  using  Douglas 

Fir  dimensional  lumber  and  data  collected  during  EPA 

emissions test.

***

Efficiencies are based on test results calculated using 

B415;  these  calculated  efficiencies  are  then  used  to 

calculate output BTU’s.

****

A peak BTU out of the appliance calculated using the 

maximum first hour burn rate from the High EPA Test and 

the BTU content of cord wood (8600) times the efficiency.

This wood appliance needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this wood appliance in a manner inconsistent with operating 

instructions in this manual.

C. Mobile Home Approved (USA ONLY)

• 

This appliance is approved for mobile home installations 

in the USA when not installed in a sleeping room and 

when an outside combustion air inlet is installed.

• 

The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained.

•  The unit must be bolted to the floor. This can be done 

using an appropriate fastener for the application.

• 

The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire, and 

chimney must be listed to UL103 HT or a listed UL-1777 

full length six” (152mm) diameter liner must be used. 

•  Mobile  Home  Brackets  must  be  installed  in  a  mobile 

home installation, supplied with stove.

D. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please contact 

your dealer for replacement glass.

Содержание Dauntless FlexBurn

Страница 1: ...the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combu...

Страница 2: ...ations 3 E Non Combustible Materials 4 F Combustible Materials 4 G California 4 2 Getting Started A Design and Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies...

Страница 3: ...6 Inch 152 mm Firebox Size 1 8 cu ft Outside Air Size 3 Inch Recommended Length 16 Inch Max Wood Length 18 Inch Fuel Orientation East West Fuel Seasoned Cordwood 20 moisture or less Weighted average...

Страница 4: ...r surfaced with any of the following materials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non pla...

Страница 5: ...hould be given serious consideration 1 Install at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the slee...

Страница 6: ...duct work and air handler joints and seams taped or sealed Basement installations should be avoided Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwd...

Страница 7: ...e with proper clearance Chimney meets recommended height requirements Minimum 16 Feet Roof flashing installed and sealed Terminations installed and sealed Clearances Combustible materials not installe...

Страница 8: ...lass surface Door opening width 24 5 8 625 mm 17 1 2 445 mm 16 3 8 416 mm 18 7 16 479 mm 23 1 16 586 mm 25 3 4 654 mm 25 5 8 651 mm 25 3 4 654 mm 13 3 8 340 mm 27 686 mm 22 5 8 575 mm Figure 3 2 Side...

Страница 9: ...ingle wall pipe 1 6 0 0 m m 8 1 0 m m 9 3 1 m m 1 4 6 7 m m 4 5 7 m m f r o n t d o o r o p e n i n g CANADA Figure 3 7 457MM FRONT DOOR OPENING 203MM 1114mm minimum 1254mm minimum 203MM Must extend 5...

Страница 10: ...Pipe 10 26 1 2 14 For Factory Alcove 6 diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A Chimney or Masonry chimney Maximum depth Alcove shall be no m...

Страница 11: ...20 Figure 3 13 Disclaimers Extended floor protection may be required for shallow installs follow floor protection requirements Full insertion installation may not allow use of the top load door depen...

Страница 12: ...chimney should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the r...

Страница 13: ...g the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other facto...

Страница 14: ...d in these installations but manufacturers are no longer permitted to specify these on EPA Certified models The chimney system should be carefully reviewed and draft tested if possible prior to instal...

Страница 15: ...ys Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements specified in Section 4B C Chimney Systems Prefabricated Metal Chimney Must be mi...

Страница 16: ...lumber to fit into wall opening Inside opening of frame should be no less than 14 x 14 356 mm x 356 mm Figure 4 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wal...

Страница 17: ...e 6 152mm UL103 HT WARNING WARNING Asphyxiation Risk DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue ga...

Страница 18: ...ll the Bottom Heat Shield NOTE TheBottomHeatShieldisrequiredinmostinstallations Refer to Floor Protection in the Dimensions and Clearances Section of this manual for further details 1 Align the bottom...

Страница 19: ...heavy stove gloves available near the stove Have special safety accessories e g Child Guard Screen available for use if small children will be in the home Fire Risk Do not leave the fire unattended wh...

Страница 20: ...e wall or flooring in your home 1 Remove all materials from packing box 2 Using a 2 Phillips screw driver attach the flex adapter to the appliance using 4 screws Figure 5 8 5 9 3 Floor Rear Installati...

Страница 21: ...rk Metalbestos DS or Security DL double wall connector or any listed double wall connector pipe 5 In Canada this appliance must be connected to a 6 152 mm factory built chimney conforming to CAN ULC 6...

Страница 22: ...mportant operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and followtheseinstructions for safe installation and operation...

Отзывы: