Stardance® Vent-Free Gas Heater

30005057

This appliance should only be connected 

by a qualified gas technician. Test to 

confirm manifold pressures as specified 

below.

The Stardance and its individual shutoff valve 

must be disconnected from the gas supply piping 

during any pressure testing of that system at test 

pressures in excess of 1/2 psig (3.5 kPa).
The Stardance must be isolated from the gas 

supply piping system by closing its individual 

manual shutoff valve during any pressure testing 

of the gas supply piping system at test pressure 

equal to or less than 1/2 psig.
There must be a gas shutoff between the stove 

and the supply.
In order to connect Natural Gas, use a fitting 

with 1/2” NPT on the valve side and 1/2” natural 

gas supply line with an input of 28,000 BTUs at a 

manifold pressure of 3.5” between minimum inlet 

supply of 5.5” w.c. and maximum of 14.0” w.c. 
In order to connect Propane, use a fitting with 1/2” 

NPT on the valve side and 1/2” propane gas sup-

ply line with an input of 28,000 BTUs at a manifold 

pressure of 11.0” between a minimum inlet sup-

ply of 11.0” w.c. and maximum of 14.0” w.c.

CAUTION

Connect the Gas Supply Line

Check the Rating Plate attached by a steel cable to the 

firebox, to confirm that you have the appropriate firebox 

for the type of fuel to be used.
The appliance should have a main gas valve provided 

in an accessible location for turning on or shutting off 

the gas to the main burner.

This appliance should only be connected by a 

qualified gas technician. Test to confirm manifold 

pressures as specified below.
The Stardance and its individual shutoff valve must 

be disconnected from the gas supply piping during 

any pressure testing of that system at test pres-

sures in excess of 1/2 psig (3.5 kPa).
The Stardance must be isolated from the gas sup-

ply piping system by closing its individual manual 

shutoff valve during any pressure testing of the gas 

supply piping system at test pressure equal to or 

less than 1/2 psig.
There must be a gas shutoff between the stove and 

the supply.
In order to connect Natural Gas, use a fitting with  

3/8” NPT nipple on the valve side and 1/2” natural 

gas supply line with an input of 28,000 Btus at a 

manifold pressure of 3.5” and minimum inlet supply 

for adjustment of 5.5” w.c. 
In order to connect Propane, use a fitting with 3/8” 

NPT nipple on the valve side and 1/2” propane gas 

supply line with an input of 28,000 Btus at a mani-

fold pressure of 11.0” and minimum inlet supply for 

adjustment of 11.0” w.c.

Gas connection should be made in accordance with 

current National Fuel Gas Code, ANSI Z223.1/NFPA 

54. Since some municipalities have additional local 

codes, be sure to consult you local authority.
Connect the gas supply and test for leaks. Use a 50/50 

solution of liquid soap and water to test for leaks at gas 

fittings and joints. 

NEVER test with an open flame.

 

Light the pilot according to the directions on Page 16, 

before going to the next step.

Install Log Set

WARNING

Failure to position the parts in accordance with 

this diagram or, failure to use only parts specifi-

cally approved with this heater, may result in 

property damage or personal injury. Do not alter 

the logs!

Loose material shall be installed per the instruc-

tions. Replacement of loose material must be 

purchased from the original room heater manu-

facturer and application of excess loose material 

may adversely affect performance of heater.

Warning: All previously applied loose material 

must be removed prior to reapplication.

1.  Remove the logs from their packaging, and inspect 

each piece for damage. 

DO NOT INSTALL DAM-

AGED LOGS.

2.  Install the rear log by placing it on the sheet metal 

shelf at the back of the firebox. (Fig. 15) The log 

should touch the back wall of the firebox and be 

centered.

Содержание 4050

Страница 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppler s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplie...

Страница 2: ...eshooting 16 Maintenance Firebox Cleaning and Inspection 18 Cleaning Procedure 18 Glass Replacement 18 Care of Cast Iron 18 Catalytic Combustor 19 Replacement Parts 20 Optional Accessories Fan Kits 24 Glass Catalyst Kit 22 Remote Controls 22 Warming Shelf 22 Warranty 23 PLEASE READ THE INSTALLATION OPERATING INSTRUCTIONS BEFORE USING APPLIANCE Thank you and congratulations on your purchase of a Ve...

Страница 3: ...ure clothing or other flam mable objects are less than 36 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas 7 DO NOT place clothing or other flammable material on or near the appliance 8 DO NOT obstruct the top grille at all Doing so will cause high levels of carbon monoxide that will lead to death 9 This heater needs fresh outside air ventilation to o...

Страница 4: ...57 Shell Dimensions Drawing Not to Scale Fig 1 Stardance freestanding shell dimensions Freestanding Stove C L C L 5004 UVS27 Freestanding specs 1 02 9 229 mm 26 6M 680 mm 3 76 mm Valve Inlet 1456O 368 mm Valve Inlet 15 6 379 mm 2556O 648 mm ...

Страница 5: ...erating the heater where im purities in the air such as tobacco smoke exist may discolor walls Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance empty space between combus tible materials and the heater as specified below for the appropriate firebox shell be...

Страница 6: ...ual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier Odor During Operation Neither natural gas nor propane gas give off an odor when burned The nature of a vent free combustion system however is such that odors may occasional ly be produced during heater operation when impuri ties exist in ...

Страница 7: ...ure proper fresh air for this and other fuel burning appliances in your home Fresh Air Requirements for Combustion and Ventilation WARNING Modern construction standards have resulted in homes that are highly energy efficient and that allow little heat loss Your home needs to breathe however and all fuel burning appliances within it require fresh air in order to function properly and safely Exhaust...

Страница 8: ...ttach rheostat to bracket MOTOR SNAPSTAT ON OFF RHEOSTAT WHT WHT BLK BLK BLK GRN BLK ST236 FK26 wiring diagram 12 99 ST236 Fig 6 Fan wiring diagram 4 Secure the snapstat wire harness to the shroud panel using the wire tie provided 5 Replace shroud and tighten the two 2 hex head nuts on lower inside of shroud 6 Route the rheostat control switch and wire forward under the stove Use the wire tie to s...

Страница 9: ... wires to the valve Fig 9 OFF ON Thermostat Optional Thermopile Black Black Millivolt Gas Valve St124b on off switch wiring 1 11 00 djt TP TH TP TH On Off Switch Wiring Optional Thermostat Remote Wiring ST124b ST124c Fig 9 ON OFF switch and optional Thermostat Remote wir ing Thermostat Remote Optional Thermopile Black Black Millivolt Gas Valve St124c Thermostat wiring 1 11 00 djt TP TH TP TH ST713...

Страница 10: ... ST353a injector orifice replace 3 21 00 djt 90 Left Burner Leg Injector Orifices ST353a Fig 12 Be sure injector orifices remain at 90 to the base 6 Slide the catalyst through the grille opening Set catalyst on top of firebox Secure with two 2 screws and washers Fig 13 7 Shoulder bolts provided in catalyst kit must be in stalled on top of firebox Use nut to secure in place Fig 13 8 Install glass f...

Страница 11: ...lated from the gas sup ply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 psig There must be a gas shutoff between the stove and the supply In order to connect Natural Gas use a fitting with 3 8 NPT nipple on the valve side and 1 2 natural gas supply line with an input of 28 000 Btu...

Страница 12: ... log down over the bent tab on the right When the log is in place it rests on the tab mentioned earlier and the tip of it comes in contact with the branch on the rear log Fig 15 4 Install the left log by placing it on the sheet metal bracket behind the grate with the left end of the log the thicker end touching the grate and the left end of the firebox Lay the log into the recessed area on the lef...

Страница 13: ...to position engaging the two steel tabs behind the adjacent bosses in the side plates Fig 17 Seat the front against the sides so the tabs at the bottom lip engage with the notches in the stove legs ST112a front plate install fully assembled 1 04 Engage steel tabs behind the cast iron bosses Control Door Bottom Tabs engage notch in the leg ST112b Fig 17 Install the Front Plate Your Front may look d...

Страница 14: ... pilot flame is correct Follow regular maintenance procedures as described on Page 18 ST673 RUVSOD Pilot assembly location 7 249 01 djt Natural Pilot LP Pilot ST673 Fig 19 Pilot assembly location Flame Temperature Adjustment RN RP Models For units equipped with HI LO valves the flame adjust ment is accomplished by rotating the HI LO adjustment knob located near the center of the gas control valve ...

Страница 15: ...ater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions To Turn Off Gas To Heater Lighting and Operating...

Страница 16: ...ilot does not light 1 Gas supply is turned off or supply line shut off valve is closed 2 Control Knob is not in PILOT posi tion 3 Control Knob not pressed in while in PILOT position 4 Air present in gas lines 5 Inlet supply pressure is not within correct settings 6 Other conditions that should be identified only by a qualified gas technician 1 Turn on gas supply or open sup ply line shut off valve...

Страница 17: ...ice technician Correct LP Pilot Flame Correct NG Pilot Flame Pilot lights but Main Burner does not 1 Gas supply line shut off valve is not fully open 2 Foreign material is blocking Burner ports 3 Main Burner orifice is clogged 4 Thermostat or remote switch not activated on JUVS 5 Bad Thermopile 1 Fully open gas supply line shut off valve 2 Insptect and clear debris away from Burner ports 3 Call lo...

Страница 18: ...G SET Use a soft bristled brush vacuum cleaner attachment to remove dust or debris from the log set pilot and burner Use care as the log set is fragile 5 Inspect the catalytic combustor at the top of the firebox Replace the combustor if any damage or deterioration is evident 6 Replace the screen or glass panel and the front plate DO NOT OPERATE THE HEATER WITH THE SCREEN GLASS PANEL OR FRONT PLATE...

Страница 19: ...ding the com bustor in place Lift combustor up and out Clean the Combustor Module 1 Clean the outer surface of the filter with the brush attachment of your vacuum cleaner to remove loose dirt 2 Submerge the filter in a mild soapy water solution Rinse thoroughly with distilled water 3 Replace in heater when dry Replace the Combustor Module 1 Replace combustor on top of firebox 2 Secure with screws ...

Страница 20: ... b 18 22 3 16a b c d 10a 10b 14a b 17 1d 23 24 25 27 28 5057 Stardance VF parts Vermont Castings Group reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice Stardance Vent Free Gas Heaters Models 4050 4051 ...

Страница 21: ... Left Black 30004082 13 Door Right Black 30004081 14a Burner Housing Assy Nat 20003130 14b Burner Housing Assy LP 20004995 15 Bracket Rear Log JUV 20003274 16a Orifice Hood 69 0292 Front LP 30000513 16b Orifice Hood 54 055 Front Nat 20000130 16c Orifice Hood 54 055 Rear LP 20000130 16d Orifice Hood 44 086 Rear Nat 30000334 17 Ignitor Piezo 14D0503 18 Gasket Base Pan Inner 20002566 19 Bracket Suppo...

Страница 22: ...The catalytic combustor installs easily into the upper mani fold above the firebox Remote Controls The remote control allows you to turn the heater on or off from anywhere in the room Remote controls are available for the Stardance only Model Functions Controlled RCB RCMT ON OFF RCBE WMTD RCST RCSTE RCT ON OFF and Temperature WWTD RCSTEB RCSITE RCSIT WT Wall mounted thermostat control Warming Shel...

Страница 23: ...er s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective i...

Страница 24: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Отзывы: