UVS27 Vent-Free Gas Heater

20007068

Provide For Adequate Ventilation

Any space within a home can be classified in the follow-
ing categories:   

 

 

 

 

1)  Unusually Tight Construction  

 

 

2)  Confined Space 

 

 

 

 

3)  Unconfined Space
First, determine which classification defines the intend-
ed space.

Unusually Tight Construction

You must provide additional fresh air if the space falls 
into this classification. Unusually Tight Construction is 
defined as construction wherein: 

   

a.  walls and ceilings exposed to the outside atmo-
sphere have a continuous water vapor retarder with a 
rating of one perm or less with openings gasketed or 
sealed and
 b.  weather stripping has been added on openable win-
dows and doors and 

   

 c.  caulking or sealants are applied to areas such as 
joints around window and door frames, between sole 
plates and floors, between wall-ceiling joints, between 
wall panels, at penetrations for plumbing, electrical, and 
gas lines, and at other openings.
If your home meets all of the three criteria above, you 
must provide supplemental fresh air for the appliance 
from outside the home as detailed on page 7, B.
If your home does not meet the above criteria, follow 
the procedure below.

Determine if You Have a Confined 

or Unconfined Space

Use the following formula to determine if you have a 
confined or unconfined space. 

Space 

is defined as the room in which you will install 

the heater plus any adjoining rooms with doorless pas-
sageways or ventilation grilles between the rooms.
The National Fuel Gas Code defines a confined space 
as a space whose volume is less than 50 cubic feet per 
1,000 BTU per hour, (4.8 m3 per kw), of the aggregate 
input rating of all appliances installed in that space and 
an unconfined space as a space whose volume is not 
less than 50 cubic feet per 1,000 BTU per hour, (4.8 m3 
per kw), of the aggregate input rating of all appliances 
installed in that space. Rooms communicating directly 
with the space in which the appliances are installed, 
through openings not furnished with doors, are consid-
ered a part of the unconfined space.

1. 

 Determine the volume of space, (length x width x 

height). Include adjoining rooms connected by doorless 
passageways or ventilating grilles. 

 

 

Vent Free Features

The UVS27, Models 4030, 4036. 4040, 4046, 4085, 
4090, is an unvented gas heating appliance tested and 
listed to the ANSI standard Z21.11.2b-2002. This ap-
pliance is specifically configured to burn either Natural 
Gas or Propane fuel, as indicated on the metal rating 
plate attached to the rear shroud. The UVS27 is not fuel 
convertible.  
The stove is shipped fully assembled and ready for 
installation.
The UVS27M is equipped with an SIT control for 
manual use only.
The UVS27R is equipped with a Honeywell control 
valve that allows thermostatic control, on/off switch or a 
remote switch (not supplied).
Both models incorporate variable regulators that al-
low you to adjust burner heat output between HIGH, 
(28,000 BTU), and LOW, (19,500 BTU). See the Opera-
tion Section for details.
The standing pilot incorporates an Oxygen Depletion 
System (ODS/pilot) designed to shut off the appliance if 
enough fresh air is not available.

This heater must have fresh air for proper opera-

tion. If not, poor fuel combustion could result. Read 

the following instructions to insure proper fresh 

air  for  this  and  other  fuel-burning  appliances  in 

your home.

Fresh Air Requirements for Combustion 

and Ventilation

WARNING

Modern construction standards have resulted in homes 
that are highly energy-efficient and that allow little heat 
loss. Your home needs to breathe, however, and all 
fuel-burning appliances within it require fresh air in 
order to function properly and safely. Exhaust fans, 
clothes dryers, fireplaces, and other fuel burning appli-
ances all use the air inside the building. If the available 
fresh air is insufficient to meet the demands of these 
appliances, problems can result.
The UVS27R/M Unvented heater has specific fresh air 
requirements.  

You must determine that these fresh 

air requirements will be met within the space where 
the appliance will be installed.

 The following informa-

tion will help you insure that adequate fresh air is avail-
able for the heater to function properly. 

Содержание 4030 - 4036

Страница 1: ...erating Manual INSTALLER DO NOT DISCARD THIS MANUAL LEAVE FOR HOMEOWNER DESIGN CERTIFIED Do not store or use gasoline or other ammable vapors and liq uids in the vicinity of this or any other applianc...

Страница 2: ...intenance Firebox Cleaning and Inspection 19 Cleaning Procedure 19 Glass Replacement 19 Care of Cast Iron 19 Catalytic Combustor 20 Replacement Parts 21 Optional Accessories Fan Kits 24 Glass Catalyst...

Страница 3: ...e to high surface temperatures DO NOT install this heater in a recreational vehicle where curtains furniture clothing or other ammable objects are less than 36 inches from the front top or sides of th...

Страница 4: ...dimensions Freestanding Stove 7068 C L 5004 UVS Hearthmount specs 1 02 5 140 mm 25 641 mm 26 673 mm 416 mm 5004 Fig 2 UVS27 Hearthmount speci cations Drawing Not to Scale Hearthmount C L C L 5004 UVS2...

Страница 5: ...blower insert heat exchanger insert or other accessory not approved for use with this heater Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance empty space between c...

Страница 6: ...risdiction WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For...

Страница 7: ...d with doors are consid ered a part of the uncon ned space 1 Determine the volume of space length x width x height Include adjoining rooms connected by doorless passageways or ventilating grilles Vent...

Страница 8: ...not be installed in a con ned space or unusually tight construction unless provisions are made for adequate combustion and ventilation air W A R N I N G If the area in which the heater may be operated...

Страница 9: ...r provided Figs 4 5 FK104 Install cover plate Rheostat Retaining Nut Control Knob FK104 Fig 7 Attach rheostat to bracket MOTOR SNAPSTAT ON OFF RHEOSTAT WHT WHT BLK BLK BLK GRN BLK ST236 FK26 wiring di...

Страница 10: ...ale connectors 2 Connect the thermostat wires to the valve Fig 11 OFF ON Thermostat Optional Thermopile Black Black Millivolt Gas Valve St124b on off switch wiring 1 11 00 djt TP TH TP TH On Off Switc...

Страница 11: ...own ST353a injector orifice replace 3 21 00 djt 90 Left Burner Leg Injector Ori ces ST353a Fig 14 Be sure injector ori ces remain at 90 to the base 6 Slide the catalyst through the grille opening Set...

Страница 12: ...th an input of 28 000 BTUs at a manifold pressure of 11 0 between a minimum inlet sup ply of 11 0 w c and maximum of 14 0 w c CAUTION Connect the Gas Supply Line Check the Rating Plate attached by a s...

Страница 13: ...bottom edge of the frame on support brackets below the front opening of the rebox Rotate the top edge of the assembly toward the rebox and center it Rotate the right and left cams towards the back of...

Страница 14: ...e Freestand ing and Pinnacle Hearthmount shells ST113a Hearthmount assy 4 20 99 djt ST113a Bottom Tabs engage notch in the base Fig 20 Engage the Hearthmount Front with the notch in the bse of each si...

Страница 15: ...mbly location 7 249 01 djt Natural Pilot LP Pilot ST673 Fig 22 Pilot assembly location Flame Temperature Adjustment RN RP Models For units equipped with HI LO valves the ame adjust ment is accomplishe...

Страница 16: ...l around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not tou...

Страница 17: ...osed 2 Control Knob is not in PILOT posi tion 3 Control Knob not pressed in while in PILOT position 4 Air present in gas lines 5 Inlet supply pressure is not within correct settings 6 Other conditions...

Страница 18: ...ce technician Correct LP Pilot Flame Correct NG Pilot Flame Pilot lights but Main Burner does not 1 Gas supply line shut off valve is not fully open 2 Foreign material is blocking Burner ports 3 Main...

Страница 19: ...se a soft bristled brush vacuum cleaner attachment to remove dust or debris from the log set pilot and burner Use care as the log set is fragile 5 Inspect the catalytic combustor at the top of the reb...

Страница 20: ...ding the com bustor in place Lift combustor up and out Clean the Combustor Module 1 Clean the outer surface of the lter with the brush attachment of your vacuum cleaner to remove loose dirt 2 Submerge...

Страница 21: ...14a b 17 1d H I OF F P IL O T LO 9c d 10c 10d 23 24 25 26 27 29 30 31 32 7068 UVS27 fa parts CFM Specialty Home Products reserves the right to make changes in design materials speci cations prices an...

Страница 22: ...dance Only Refer to Enamel Parts Chart Page 24 12 Door Left Stardance Refer to Enamel Parts Chart Page 24 13 Door Right Stardance Refer to Enamel Parts Chart Page 24 14a Burner Housing Assy JUV NG 200...

Страница 23: ...9 1341129 1341087 Shell Enamel Part Numbers Freestanding Models 4030 4036 4040 4046 Color Top Left End Right End Front OP Left Door Right Door Classic 30001278 30001280 30001279 30001496 30001139 3000...

Страница 24: ...control allows you to turn the heater on or off from anywhere in the room Remote controls are available for the UVS27R only Refer to Figure 17 Page 12 for wiring diagram Model Function s Controlled MR...

Страница 25: ...25 UVS27 Vent Free Gas Heater 20007068...

Страница 26: ...26 UVS27 Vent Free Gas Heater 20007068...

Страница 27: ...op Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of...

Страница 28: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: