CFDV Series Gas Fireplace

20305832

3

3. For 

propane/LP 

fi replace, do not place propane/LP 

supply tank(s) inside any structure. Locate propane/LP 
supply tank(s) outdoors. To prevent performance prob-
lems, do not use propane/LP fuel tank of less than 100 
lbs. capacity. 

4.  If you smell gas:

 

Shut off gas supply.

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use any 
phone in your building .

• 

Immediately call your gas supplier from a neighbor’s 
phone. Follow the gas supplier’s instructions.

5.  Never install the fi replace:

• 

In a recreational vehicle

 

Where curtains, furniture, clothing, or other fl am-
mable objects are less than 36" from the front, top, 
or sides of the fi replace

 

In high traffi c areas

 

In windy or drafty areas 

6. 

Due to high temperatures, the appliance should be 
located out of traffi c and away from furniture and 
draperies.

7. This 

fi replace reaches high temperatures. 

Children 

and adults should be alerted to the hazards of high 
surface temperature and should stay away to avoid 
burns or clothing ignition.

 Fireplace will remain hot 

for a time after shutdown. Allow surfaces to cool before 
touching. 

8. 

Young children should be carefully supervised 
when they are in the same room as the appliance. 
Toddlers, young children and others may be sus-
ceptible to accidental contact burns. A physical 
barrier is recommended if there are at risk individu-
als in the house. To restrict access to a fi replace 
or stove, install an adjustable safety gate to keep 
toddlers, young children and other at risk individu-
als out of the room and away from hot surfaces.

 

9. 

Clothing or other fl ammable material should not be 
placed on or near the appliance.

10. When the appliance is installed directly on carpeting, 

tile or other combustible material other than wood fl oor-
ing, you must set appliance on a metal or wood panel 
or hearth pad extending the full width and depth of the 
appliance.

11.  Do not modify fi replace under any circumstances. Any 

parts removed for servicing must be replaced prior to 
operating fi replace. 

12. Turn fi replace off and let cool before servicing, install-

ing, or repairing. Only a qualifi ed service person should 
install, service, or repair the fi replace. Have burner 
system inspected annually by a qualified service 
person. 

IMPORTANT SAFETY INFORMATION

This fi replace is a vented product. This fi replace must be 
properly installed by a qualifi ed service person. The glass 
door must be properly seated and sealed. If this unit is not 
properly installed by a qualifi ed service person with glass 
door properly seated and sealed, combustion leakage can 
occur. 

CARBON MONOXIDE POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the fl u with headaches, 
dizziness and/or nausea. If you have these signs, the fi re-
place may not have been installed properly. Get fresh air 
at once! Have the fi replace inspected and serviced by a 
qualifi ed service person. Some people are more affected 
by carbon monoxide than others. These include pregnant 
women, people with heart or lung disease or anemia, 
those under the infl uence of alcohol, and those at high 
altitudes. 

Propane/LP gas and natural gas are both odorless. An 
odor-making agent is added to each of these gases. The 
odor helps you detect a gas leak. However, the odor added 
to these gases can fade. Gas may be present even though 
no odor exists.

Make certain you read and understand all warnings. Keep 
this manual for reference. It is your guide to safe and proper 
operation of this fi replace.

1. 

Installation and repair should be done by a qualifi ed 
service person. The appliance should be inspected 
before use and at least annually by a professional 
service person. More frequent cleaning may be 
required due to excessive lint from carpeting, 
bedding material, et cetera. It is imperative that 
control compartments, burners and circulating air 
passageways of the appliance be kept clean.

2.  This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 
convertible for use with other gases unless a certifi ed 
kit is used. 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

• 

Read this owner’s manual carefully and 
completely before trying to assemble, operate, 
or service this fi replace. 

•  Any change to this fi replace or its controls can 

be dangerous.

•  Improper installation or use of this fi replace 

can cause serious injury or death from fi re, 
burns, explosions, electrical shock and carbon 
monoxide poisoning.

W

ARNING

Содержание 36CFDV

Страница 1: ...ach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteratio...

Страница 2: ...Remote Systems 30 Optional Fan Blower System BLOT 31 Optional Fan Blower System FK12 31 Operating Instructions Millivolt 32 For Your Safety Read Before Lighting 32 What To Do If You Smell Gas 32 Light...

Страница 3: ...all service or repair the fireplace Have burner system inspected annually by a qualified service person IMPORTANT SAFETY INFORMATION This fireplace is a vented product This fireplace must be properly...

Страница 4: ...or any other accessory not approved for use with this fireplace 24 Do not operate appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed qualif...

Страница 5: ...0 feet 1 370 m GAS SPECIFICATIONS ORIFICE SIZE GAS PRESSURES Natural Propane LP Inlet Minimum 5 5 w c 11 0 w c Inlet Maximum 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c Off Pilot On Knob Hi L...

Страница 6: ...ents and for firebox dimensions The framing headers may rest on the top of the firebox standoffs Do not bring headers below top of standoffs The firebox may be installed directly on a combustible floo...

Страница 7: ...ONS A 37 940 mm 41 1042 mm B 381 2 978 mm 381 2 978 mm C 343 4 883 mm 343 4 883 mm D 291 8 740 mm 331 8 841 mm E 197 8 505 mm 197 8 505 mm F 157 8 430 mm 157 8 430 mm G 221 8 562 mm 261 2 673 mm H 255...

Страница 8: ...al codes includ ing permits and inspections The following factors should be taken into consideration Clearance to side wall ceiling woodwork and windows Minimum clearances to combustibles must be main...

Страница 9: ...ure fireplace to the floor Use four 4 screws to attach fireplace to framing The side nailing flanges are 1 2 or 5 8 to accommodate different wall thickness FINISHING MATERIAL NOTE Any wiring i e remot...

Страница 10: ...aside Figure 9 Remove Screws Remove Screws 7 Collar FP3022 Figure 9 Remove 7 Collar and Gasket 3 Remove the plate with the 4 collar and gasket by re moving four 4 screws Set aside Figure 10 4 Remove...

Страница 11: ...Gasket 7 Remove the small square plate and gasket by removing four 4 screws Set aside Figure 13 Remove Screws Small Square Plate FP3027 Figure 13 Remove Small Square Plate and Gasket 8 Install the pl...

Страница 12: ...h the side wall or vertical through the roof Only Vermont Castings Group venting components specifically approved and labeled for this fireplace may be used Flexible UL1777 listed venting may be used...

Страница 13: ...ances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clearance to permanently closed...

Страница 14: ...ocal codes and or the current National Fuel Code ANSI Z223 1 NFPA 54 Canadian Installations The venting system must be installed in accordance with the current CSA B149 1 installation code FLEX VENT P...

Страница 15: ...assembly the joints we suggest put ting a lubricant Vaseline or similar on the male end of the twist lock pipe prior to assembly Male End Female End Screw Holes TWL100 Figure 18 Twist lock Pipe Joints...

Страница 16: ...and position the fire place in accordance with same EXAMPLE A If the vertical dimension from the floor of the unit is 11 3 4 m the horizontal run to the face of the outer wall must not exceed 14 4 3...

Страница 17: ...ARNING Rear Top Vent Vertical Side wall Horizontal sections of this vent system require a minimum of 3 76 mm clearances to combustibles at the top of the flue and 1 25 mm clearance at the sides and bo...

Страница 18: ...ombustible Walls Hole opening should be 71 2 191 mm diameter Step 2 Secure firestop to the inside frame center in the 95 8 x 95 8 vent opening Step 3 Measure the horizontal length requirement for the...

Страница 19: ...bus tible materials is 3 76 mm on top and 1 25 mm on the bottom and sides unless otherwise noted When vent termination exits through foundations less than 20 508 mm below siding outcrop the vent pipe...

Страница 20: ...run the length of the horizontal run MUST be reduced by 18 457 mm This does not apply if the 45 elbows are installed on the vertical part of the vent system The maximum number of elbow degrees in a sy...

Страница 21: ...ed flue restrictors onto the top edge of the firebox flue adapter according to the Vertical Side wall Installation Flue Restrictor Chart Step 1 Locate vent opening on the wall It may be necessary to f...

Страница 22: ...w Step 1 and 2 on Page 21 Step 3 Install the four 4 spacer springs on the 4 flex vent pipe When installing the spacer springs around the 4 pipe stretch the spring to approximately 15 381 mm wrap the s...

Страница 23: ...nting clearances are observed If venting system is installed below ground we rec ommend a window well with adequate and proper drainage to be installed around the termination area If installing a snor...

Страница 24: ...uced by 18 450 mm Example Maximum horizontal length No elbows 10 3 m 1 x 45 elbow 8 5 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 2 5 m vertical rise is required Two sets of 45 elbow offsets may be...

Страница 25: ...ual to 93 4 x 93 4 248 x 248 mm 4 Proceed to plumb for additional openings through the roof In all cases the opening must provide a minimum of 1 inch clearance to the vent pipe i e the hole must be at...

Страница 26: ...feet Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 H Minimum height from roof to lowest d...

Страница 27: ...to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regula tor damage could occur Install external regulator with the vent pointing down as shown in Figure 51...

Страница 28: ...t lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in clogged burner system valve We recommend that you install a sediment trap drip l...

Страница 29: ...he factory 3 The junction box cover has a factory installed romex style strain relief connector After connecting the wires route the wire leads through this connector Refer to the wiring diagram in Fi...

Страница 30: ...m for Wall Switch ELECTRICAL INSTALLATION MILLIVOLT REMOTE WALL SWITCH Position the wall switch Do not extend beyond the 15 feet of wire OPTIONAL DC REMOTE SYSTEMS See section entitled Hearth Mount in...

Страница 31: ...ed This system requires that 110 120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed Figure 56 Black Black Green Black Black White Thermostatic Swit...

Страница 32: ...ified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician...

Страница 33: ...1 and 2 LIGHTING PILOT Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made joints gas shutoff...

Страница 34: ...position It will take less than four 4 seconds for the burner to ignite MAIN BURNER SWITCH This switch allows you to turn on and to turn off the main burner without using the gas valve knob is in the...

Страница 35: ...ot use open flame to check for gas leaks ELECTRICAL WIRING General 1 This fireplace is equipped with an IPI control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junct...

Страница 36: ...leads through this connector Refer to the wiring diagram in Figure 59 Figure 59 Junction Box Wiring Diagram Junction Box Factory Supplied Not Supplied 120V AC 60Hz ELECTRICAL INSTALLATION IPI WALL SW...

Страница 37: ...Switch DC Power Green Ground Gas In Gas Out Pilot Gas Tubing Valve Cold Climate Switch Main Switch ELECTRICAL INSTALLATION IPI CAUTION Electrical connections should only be performedbyaqualified lice...

Страница 38: ...one Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department C Turn Master Switch to ON position by hand Never use tools If the switch will not function b...

Страница 39: ...ow B in the safety information on Page 38 If you do not smell gas go to next step 4 Press the wall switch to the ON position Sparker will spark and pilot flame will light 5 Once pilot flame is establi...

Страница 40: ...p Cover Missing One RED 1 time Spark Fail Two RED 1 time No Sensor Signal Three RED 1 time Trial Lockout One GREEN every 2 seconds until manual reset Flames Loss Lockout One RED GREEN every 2 seconds...

Страница 41: ...ard and up Figure 61 3 Tilt glass frame out and lift glass frame up and away Figure 62 4 Set glass frame aside Figure 62 Remove Glass Frame Glass Frame FP3015 CAUTION Each latch has a quick spring for...

Страница 42: ...the flame is blue and only in the center turn off unit and let cool After unit is cool remove logs and check to make sure rock wool is placed correctly Replace logs NOTE The type of installation vent...

Страница 43: ...all the center firebrick panel on the back wall first Stand firebrick panel straight up against the back of fireplace with the bottom edge at bottom of inner firebox 4 Repeat Step 3 with the left and...

Страница 44: ...tab in the center front of the false hearth up to a 90 angle Figure 71 Place the top log 4 by resting the square notch located on the bottom of the log over the tab mentioned above Rest the top part...

Страница 45: ...Center Tab Figure 71 LG1183 Figure 73 WARNING Do not sprinkle the lava rock on top of the burner This may cause potential sooting glass breakage and a fire hazard LAVA ROCK PLACEMENT Sprinkle lava ro...

Страница 46: ...places and tilting frame for ward Lift off and set aside 4 Remove the logs if they are installed Vacuum the rock wool off the burner 5 Remove the four 4 pin log plate assemblies by re moving the two 2...

Страница 47: ...to cool before removal NEVER use abrasive materials Keep children and pets a safe distance away Never operate the fireplace without the glass door properly secured Never operate the fireplace if the...

Страница 48: ...re that the thermocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other m...

Страница 49: ...ss does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check valve connections Check power supply go through A...

Страница 50: ...B Glass Kit Diamond GKD Glass Kit Onyx GKO Glass Kit Sapphire GKS Blower Kits T Stat Blower w Speed Control BLOT Manual Blower FK12 Speed Control 26D0746 SYMPTOM POSSIBLE CAUSE ACTION The pilot and ma...

Страница 51: ...06K 20305806K Factory Installed Service Parts 3 Thermostat Sensor for Blower 26D2870 Firebrick Cottage Clay 4 Rear 1 20305737K 20305801K 5 Left 1 20305739K 20305803K 6 Right 1 20305738K 20305802K Fire...

Страница 52: ...s Fireplace 52 20305832 REPLACEMENT PARTS 1 2 3 4 LOGS REF DESCRIPTION 36CFDV 42CFDV 1 Rear Log 54D0117K 54D0331K 2 Bottom Left Log 54D0118K 54D0118K 3 Bottom Right Log 54D0119K 54D0119K 4 Top Log 54D...

Страница 53: ...4K 3 Gas Valve Assembly 1 37D0117 37D0118 37D0117 37D0118 4 Pilot Assembly 1 37D0018K 37D0019K 37D0018K 37D0019K 5 Replacement Thermocouple 1 24D0808 24D0808 24D0808 24D0808 6 Replacement Igniter and...

Страница 54: ...6019K 20306019K 3 Gas Valve Assembly 1 95E0101 95E0101 95E0101 95E0101 4 Pilot Assembly 1 95E0103 95E0104 95E0103 95E0104 5 Control Board 1 95E0108 95E0108 95E0108 95E0108 6 Control Box 1 95E0100 95E0...

Страница 55: ...ck Pipe 20 Rigid Pipe single pack 7TDVP20 30 Flex Pipe single pack 7FDVP30 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack...

Страница 56: ...ination Screen Guard 7TBSG Up and Out Starter Kit w 40 Flex Pipe Firestop Cool 7FDVSCTK Touch Termination w Siding Shield and 2 ea Clamp Bands Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 1...

Страница 57: ...pipe length galvanized 46DVA 12 3 6 24 pipe length galvanized 46DVA 24 3 6 36 pipe length galvanized 46DVA 36 3 6 48 pipe length galvanized 46DVA 48 4 6 81 2 pipe length galvanized 46DVA 08A 4 6 16 p...

Страница 58: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2...

Страница 59: ...Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage...

Страница 60: ...y 40361 www vermontcastingsgroup com EFFICIENCY RATINGS MODEL ENERGUIDE RATINGS FIREPLACE EFFICIENCY PERCENTAGE D O E AFUE PERCENTAGE 36CFDVNV 63 0 62 01 36CFDVPV 67 7 66 16 36CFDVNI 66 2 62 01 36CFDV...

Отзывы: