21
2003135
ST670a
RUVSOD
snapstat
7/01
Snapstat Bracket
Snapstat Module
Pinch Grommet
to Remove
Figure 69
- Remove the snapstat and grommet from the bracket.
ST720
attach snapstat
8/02
Left Air Duct
Inner
Shroud
Grommet
Fan
Figure 70
- Attach snapstat wire assembly to inside of inner shroud
with clamp screws.
ST194
attach fan to shroud
11/99
Slot
Outer
Shroud
Slot
Inner Shroud
Figure 71
- Position the fan to engage the inner shroud with the fan
bracket slots and secure with sheet metal screws.
ST671
attach snapstat
Left Air Duct
Snapstat
Figure 72
- Install the snapstat and connect the extension wire
terminals. View is with top removed, however, access is available
through the rear when installing fan before gas line connection.
ST758
Dutchwest
attach rheostat
5/15/03 djt
Rheostat
Retaining nut
Rheostat Knob
Rheostat
Figure 73
- Attach the fan rheostat.
•
Remove retaining nut from shaft of rheostat. (if
preinstalled)
•
Insert the rheostat through the hole in the back of the
left side of the valve bracket, aligning the locator pin
with the smaller hole in that bracket.
•
Thread the retaining nut onto the shaft of the rheostat,
tightening with a wrench. Do not overtighten.
•
Attach the control knob to the rheostat shaft.
•
Use the wire tie to secure the fan and rheostat wire
harnesses together.
9. Plug the power cord into a standard grounded 110 volt
household outlet. If the fan control knob is not turned to
the OFF position, the fan will turn on when the temperature
at the snapstat reaches approximately 109°F.
5. Assemble the inner shroud to the outer shroud using
previously removed screws.
6. Position the fan assembly so the ducts slide between the
inner and outer shroud. The inner shroud should engage
with the two slots in the ends of the bracket so the bracket
and shroud are interlocked. (Figure 71) Secure the bracket
with the four sheet metal screws provided in the finish bag.
7. Install the snapstat by loosening the front screw on the
inner side of the duct. (Figure 72) Slide the snapstat under
the head of the screw and tighten. Connect the leads to
the snapstat. Make sure the snapstat assembly is mounted
straight front to back.
8. After sliding the firebox in place, the rheostat control switch
attaches to the left side of the valve bracket at the front
of the stove. (Figure 73)
3. Disassemble the inner shroud from the outer shroud by
removing the four screws, two on each side.
4. Place the grommet provided in the parts bag assembly on
the inner shroud. Run the snapstat extension assembly
leads through the grommet toward the firebox. (Figure 70)