background image

DESCO EUROPE

 - 2A DUNHAMS LANE, LETCHWORTH, HERTFORDSHIRE, SG6 1BE, UK

Phone: +44 (0) 1462 672005 • E-mail: 

[email protected]

, Website: 

DescoEurope.com

TB-7594

 Page 1 of 2

© 2018 DESCO INDUSTRIES INC

Employee Owned

Made in the

United States of America

Portable Wrist Strap Tester

Installation, Operation and Maintenance

Description

Per EN 61340-5-1, test equipment is required to enact 

the Compliance Verification Plan Requirement. Test 

equipment shall be selected to make measurements of 

appropriate properties of the technical requirements that 

are incorporated into the ESD programme plan. The 

Wrist Strap Tester can be used to fulfill

IEC 61340-4-6. “The typical verification frequency, used 

by industry, for wrist cords is once per shift due to the 

wrist cord’s importance to the success of the program 

and the likelihood of failure.” (CLC/TR 61340-5-2 

clause 4.3.3 Verification frequency). Being a portable 

battery powered tool, it is perfect for small labs or 

for a supervisor to spotcheck workers and/or ensure 

compliance.
The Vermason 

225221

 Portable Wrist Strap Tester is a 

battery operated “on demand” wrist strap tester. When 

the wearer of a wrist strap plugs in their coiled cord and 

touches the metallic surface of the Wrist Strap Tester, 

a path for current flow is completed from the wearer’s 

skin, through the wrist strap. This action will cause 

the green “test good” LED to illuminate as long as the 

resistance of the circuit path is between 750 kilohms 

and 35 megohms.

Packaging

1  Wrist Strap Tester

1  9 V Alkaline Battery

1  Hook and Loop Fastener Strip

1  Certificate of Calibration

July 2018

Figure 1. Vermason 

225221

 Portable Wrist Strap Tester

Installation

Open the tester’s battery compartment and install 

the included 9 V battery. Use the included hook and 

loop fastener strip to mount the tester to a wall or 

worksurface.
NOTE: The low battery indicator flashes briefly every 

time the unit is used. Replace the battery once the 

indicator becomes constant during testing.

Operation

1.  While wearing a wrist strap, plug the wrist cord 

into the wrist strap jack located on the face of the 

Portable Wrist Strap Tester.

2.  Push down and hold the test switch until the test 

results are displayed. Ensure that your finger also 

makes contact with the metal ring around the 

pushbutton when performing a test. 

DO NOT touch any other metal while performing 

your test as this will affect your results.

3.  A pass test result is indicated by illumination of the 

green PASS LED. A fail low test result is indicated 

by illumination of the red LOW LED. A fail high test 

result is indicated by illumination of the red HIGH 

LED. 

If your ESD test fails, check your wrist strap and

ensure that it is being worn correctly and/or needs

to be replaced.

NOTE 1: The Portable Wrist Strap Tester may briefly

display “FAIL HIGH” once the test button is released at

the conclusion of a test. Residual voltage in the circuit’s

capacitors causes the test to continue for a split second

after the button is released.

NOTE 2: Failures may be caused by dry skin or minimal

sweat layer. For wrist straps, try using an approved

dissipative hand lotion such as 

Reztore® ESD

Hand Lotion

 to your wrist prior to use.