![Verlinde STAGEMAKER COMPACT SM1 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/verlinde/stagemaker-compact-sm1/stagemaker-compact-sm1_installation-and-maintenance-manual_1005369016.webp)
9807 / 9.3
9-2.3 Power diagram
D
Supplied by customer
A
Electric trolley
Y21
Brake
F1-F2-F3 Fuse (customer)
M
Motor
Q1
Power switch (customer)
K10
Emergency stop contactor
K21
Lifting contactor
K22
Lowering contactor
K25
Speed selector
T100
Control transformer
X1
Terminal board
X22
Supply connection plug (OPTION)
X24
Trolley connection plug
G41
Rectifier
CAUTION !
The supply cable must be equiped with a power switch or an isolator in conformity with the regulation.