background image

Table A-8

Power Cooling Module components

Component

Number

Power Cooling Module LEDs

See

“Power Cooling Module LEDs”

on page 45.

1

On/Off switch

2

Release tab

3

AC power socket

4

Serial number - located on the Power Cooling Module 0 tab

Note:

The storage shelf serial number begins with the letters

SH

.

5

Power Cooling Module LEDs

Power Cooling Modules (PCM) use four LEDs to indicate the status of the PCM.

45

About the optional Veritas 2U12 49TB Storage Shelf

Components of the Veritas 2U12 49TB Storage Shelf

Содержание NetBackup 5230 Appliance

Страница 1: ...Veritas NetBackup 5230 Appliance and Storage Shelf Product Description ...

Страница 2: ...hnologies LLC and its licensors if any THE DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID VERITAS TECHNOLOGIES LLC SHALL NOT BE LIABLE FOR INCIDENTAL OR C...

Страница 3: ... sort veritas com documents Documentation feedback Your feedback is important to us Suggest improvements or report errors or omissions to the documentation Include the document title document version chapter title and section title of the text on which you are reporting Send feedback to APPL docs veritas com You can also see documentation information or ask a question on the Veritas community site...

Страница 4: ...s 3U16 24TB Storage Shelf Veritas 3U16 36TB Storage Shelf 19 Appliance and storage shelf connections 21 NetBackup 5230 documentation 24 Chapter 2 Cables 25 Power cables 25 Network cable 26 Multi Mode fiber optic cable 26 SAS cable 27 Chapter 3 Technical specifications standards and compliance information 29 Technical specifications 29 Environmental specifications 32 Protocol standards 33 Appendix ...

Страница 5: ...Veritas 2U12 49TB Storage Shelf rear components 39 Index 48 5 Contents ...

Страница 6: ... configurations About the 2 port 8 Gb FC HBA About the dual port 10 Gb Ethernet card About the Veritas 3U16 24TB Storage Shelf Veritas 3U16 36TB Storage Shelf Appliance and storage shelf connections NetBackup 5230 documentation About the appliance The NetBackup 5230 appliance and the Storage Shelf provide complete deduplication and backup solutions This document describes the major hardware aspect...

Страница 7: ...gh KVM over IP Supports the SNMP traps and automatically reports alarms Supports reporting the disk information through the out of band management channel Easy management 64 GB up to a maximum of 192 GBs Note You can purchase additional 64 GB memory kits to maximize the amount of memory in the NetBackup 5230 Appliance You can also use the memory kits to increase the appliance memory when you add a...

Страница 8: ...ore 2 5GHz E5 2620 CPUs An appliance with 4 TBs of internal storage and zero storage shelves contains eight 8Gb DIMMs An appliance with 14 TBs of internal storage and zero storage shelves contains eight 8Gb DIMMs An appliance with 4 TBs of internal storage and one or more storage shelves contains sixteen 8Gb DIMMs An appliance with 14 TBs of internal storage and one or more storage shelves contain...

Страница 9: ...30 rear panel configurations on page 16 Rear panel ports See About the appliance rear panel on page 12 The technical specification section contains dimensions and weights for both types of devices See About storage capacity on page 9 About storage capacity The standard NetBackup 5230 Appliance without attached storage shelves provides 4 55 TB of storage capacity This configuration uses 1 TB storag...

Страница 10: ...s 3U16 24TB Storage Shelf Veritas 3U16 36TB Storage Shelf on page 19 See About the optional Veritas 2U12 49TB Storage Shelf on page 34 Table 1 2 NetBackup 5230 storage capacity options Appliance and four storage shelves MSDP available storage capacity TB Appliance and three storage shelves available MSDP storage capacity TB Appliance and two storage shelves available MSDP storage capacity TB Appli...

Страница 11: ...connect the shelves Finally the SAS3 data transfer rate of the 2U12 49TB Storage Shelf drops to match the SAS2 data transfer rate of the 3U16 24TB or 36TB Storage Shelf See About the optional Veritas 2U12 49TB Storage Shelf on page 34 Note Connecting up to four Veritas 3U16 24TB or 36TB Storage Shelves requires the NetBackup 5230 Appliance to be running appliance software version 2 6 0 2 or later ...

Страница 12: ... extensible to 36 914mm This distance is the maximum depth that is allowed between rack posts If the distance between rack posts is longer than 36 914mm the rails and the appliance cannot be properly installed The width of the storage shelf is 19 482 6mm If your rack dimensions do not conform to these requirements contact Veritas Technical Support Populate the bottom of the rack with heavier devic...

Страница 13: ...th1 NIC3 eth2 and NIC4 eth3 reserved for public networks All three are 1Gb connectors 4 5 6 DB 15 VGA connector 7 RJ45 Serial A port reserved 8 USB connectors 9 IPMI remote management port 10 NIC5 eth4 and NIC6 eth5 left to right 10Gb network connectors for public networks 11 Add in PCIe adapter slots SAS Fibre Channel 10Gb Ethernet 12 Serial B port reserved 13 Starting in January 2014 NetBackup a...

Страница 14: ...height 3 5 form factor PCIe slots The following diagram shows the slot numbers 1 through 6 Riser assembly 2 includes slots 1 2 and 3 Riser assembly 1 includes slots 4 5 and 6 Fibre channel cards are shown in slots 5 and 6 This configuration is one of several options Figure 1 4 Rear panel slot numbers 14 Product overview About the appliance rear panel ...

Страница 15: ...at the factory on the mainboard of the appliance This controller is also known as the internal controller The SAS RAID controller that is installed in the PCIe riser slot is known as the external controller The mainboard RAID controller includes a maintenance free backup unit MFBU with a super capacitor and flash memory The parameters that are associated with the controller are as follows Dimensio...

Страница 16: ... ordered as separate devices Table 1 4 NetBackup 5230 rear panel configurations Slot 6 Slot 5 Slot 4 Slot 3 Slot 2 Slot 1 Configuration Not populated Not populated Not populated Not populated Not populated Not populated A Not populated Not populated Dual 8 Gb Fibre Channel Not populated Not populated Not populated B Not populated Not populated Dual 8 Gb Fibre Channel Dual 10 GbE Ethernet Not popul...

Страница 17: ...onfiguration D notes You can use the FC ports in slots 2 and 4 for VMware Optimized Deduplication over FC or tape library connectivity Both ports on each card are configured in Initiator mode You can use the FC ports in slots 5 and 6 for Fibre Transport media server FTMS support Understand that port 1 on the FC HBA cards in slots 5 and 6 is configured in Target mode The other port on these cards i...

Страница 18: ...configurations support the appliance to work as a replication target for Optimized Duplication and Auto Image Replication For more information about available HBA cards for target port use refer to the NetBackup Appliance Fibre Channel Guide Figure 1 6 FC HBA card target and initiator ports See About the NetBackup 5230 rear panel configurations on page 16 About the 2 port 8 Gb FC HBA The Fiber Cha...

Страница 19: ...escription Feature Holds 16 3 5 inch 2 TB or 3 TB 7 200 rpm SAS disk drives Note The disk capacities that are used in the 3U16 storage shelves depends on the 3U16 storage shelf model that you purchase For example the Veritas 3U16 24TB Storage Shelf uses 2 TB disks and offers 24 terabytes of usable storage capacity The Veritas 3U16 36TB Storage Shelf uses 3 TB disks and offers 36 terabytes of usabl...

Страница 20: ...age Shelf front panel components Component Number Disk module 1 of 16 1 Disk module release button 2 Disk status LED 3 Disk power and activity LED 4 Slot 16 hot spare 5 Figure 1 8 Veritas 3U16 24TB Storage Shelf Veritas 3U16 36TB Storage Shelf rear panel Table 1 7 lists the 3U16 storage shelf rear panel components that are shown in the illustration 20 Product overview About the Veritas 3U16 24TB S...

Страница 21: ...lf Figure 1 9 Serial number tab Appliance and storage shelf connections When more than one storage shelf is used SAS cables connect the second shelf to the first shelf The second shelf is not physically connected to the appliance Network cables for use with Fibre Channel ports or Ethernet ports are not provided Customers must supply any Fibre Channel or Ethernet cables The following figure shows t...

Страница 22: ...n to two storage shelves Component Number Appliance 1 Appliance SAS_IN and SAS_OUT ports 2 Storage Shelf SAS_IN ports connecting to the appliance 3A Storage Shelf SAS_IN ports connecting to another storage shelf 3B Storage Shelf SAS_OUT ports only used to connect to SAS_IN ports on other storage shelves 4 Storage shelves 5 22 Product overview Appliance and storage shelf connections ...

Страница 23: ...0 3 the use of up to four storage shelves with one appliance is supported Table 1 8 also lists the components in the four shelf configuration Figure 1 11 Four storage shelves and one appliance 23 Product overview Appliance and storage shelf connections ...

Страница 24: ...p 5230 appliance runs NetBackup appliance software to provide deduplication and advanced storage backup capabilities Documentation for the appliance and for the NetBackup software is available at the following link NetBackup Appliance Documentation See About the appliance on page 6 24 Product overview NetBackup 5230 documentation ...

Страница 25: ...pliance and the storage shelves accept one AC power cable One end of the AC power cable is connected to the power supply on the appliance or the storage device The other end of the cable is connected to an external Power Distribution Unit PDU on the rack A power cable includes live line neutral line and grounding lines Figure 2 1 AC power cable A B 2 Chapter ...

Страница 26: ... cable One end of the network cable connects to the management network port or service network port of the appliance The other end of the cable connects to the network switch or an external gateway Both ends of the cable use RJ45 connectors Figure 2 2 Network cable Multi Mode fiber optic cable The NetBackup Appliance communicates with the Fibre Channel switch through a multi mode fiber optic cable...

Страница 27: ...are provided with each device having Fibre Channel ports The diagram shows the SFP labeled 1 and the fiber optic cable which is attached to it labeled 2 Supported SFPs are listed Finisar JDSU SAS cable A SAS cable has a SAS connector on both ends Two SAS cables ship with each Expansion Storage Shelf 27 Cables SAS cable ...

Страница 28: ...Figure 2 4 SAS cable Refer to the NetBackup Appliance and storage shelf connection sections as needed for details 28 Cables SAS cable ...

Страница 29: ...cifications Protocol standards Technical specifications Appliance technical specifications Table 3 1 provides technical specifications for the 5230 Appliance Table 3 2 provides technical specifications for the 5230 Appliance storage shelf Table 3 1 Appliance technical specifications Description Parameter 19 EIA standard Rack information 3 Chapter ...

Страница 30: ... Specification IEC 60320 C14 to IEC 60320 C13 10A 250V Black 4 ft The IEC 60320 C14 plugs into a Power Distribution Unit The IEC 60320 C13 plugs into an appliance or storage shelf power supply Note If your power distribution unit is not compatible with the IEC 60320 C14 plug then Veritas recommends that you purchase your power cable locally Make sure the power cable meets or exceed the indicated p...

Страница 31: ...ck cabinet that is 19 inches 48 26 cm wide The rack rails that are provided for the Storage Shelf are extensible to 36 914mm This distance is the maximum depth that is allowed between rack posts If the distance between rack posts is longer than 36 914mm the rails and the appliance cannot be properly installed Rack information Maximum weight 32 5 kg 71 65 lb Note The maximum weight of a storage she...

Страница 32: ...nts for the NetBackup appliance and the storage devices Table 3 3 Environmental requirements Requirement Component 10 C to 35 C 50 F to 95 F Operating temperature 40 C to 70 C 40 F to 158 F Storage temperature 40 C to 70 C 40 F to 158 F Transportation temperature 10 C hour Temperature gradient 10 RH to 85 RH Operating humidity 30 meters to 3 000 meters In altitudes from 60 meters to 1 800 meters t...

Страница 33: ... the NetBackup appliance and storage devices comply Table 3 4 Standards compliance Version Standard Intelligent Platform Management Interface Specification Second Generation v2 0 Document Revision 1 0 IPMI 2 0 System Management BIOS SMBIOS Reference Specification Version 2 5 SMBIOS SAS 2 1 SAS Advanced Configuration and Power Interface Specification Revision 3 0 September 2 ACPI RFC0791 Internet P...

Страница 34: ...rpm SAS hard disk drives Available storage capacity of the storage shelf is 49TBs Each disk drive can be accessed from the storage shelf s front panel An embedded RAID controller is used to configure the disk drives into a RAID 6 configuration One of the disk drives is reserved as a hot spare The Veritas 2U12 49TB Storage Shelf also contains two Storage Bay Bridge 2 1 compliant SBB Input Output I ...

Страница 35: ...helf serial number begins with the letters SH See Veritas 2U12 49TB Storage Shelf front panel components on page 35 See Veritas 2U12 49TB Storage Shelf rear components on page 39 See Veritas 2U12 49TB Storage Shelf control panel on page 37 Components of the Veritas 2U12 49TB Storage Shelf The following sections describe the components of the Veritas 2U12 49TB Storage Shelf Veritas 2U12 49TB Storag...

Страница 36: ...EDs Note that the combination of both LEDs provides the status Table A 1 Veritas 2U12 49TB Storage Shelf disk drive carrier LED status Fault amber LED Activity green LED Status OFF OFF No disk drive installed OFF Blinks during I O activity and during startup Drives are installed turned on and operational Blinks at a rate of 1 second ON and 1 second OFF ON SCSI Enclosure Services SES Device identit...

Страница 37: ...st be unlocked using a T10 screw driver Veritas 2U12 49TB Storage Shelf control panel The Veritas 2U12 49TB Storage Shelf control panel is installed on the front left side of the storage shelf Figure A 3 Veritas 2U12 49TB Storage Shelf control panel 1 3 4 5 2 37 About the optional Veritas 2U12 49TB Storage Shelf Components of the Veritas 2U12 49TB Storage Shelf ...

Страница 38: ...ated with the shelf s disk drives However the Logical Status LED can also indicate an issue with an internal RAID controller or external RAID controller or with a host bus adapter Logical status LED amber 4 The Unit Identification Display is a dual digit display that provides information about the storage shelf Its primary function is to assist in the configuration of multiple storage shelves Unit...

Страница 39: ...e installed Invalid or Mixed Power Cooling Module Fault LEDs Fan Fault LEDs N A Flashing On Green Drive failure has occurred causing loss of availability or redundancy Array in a failed or degraded state On N A On Green Array operating background function Arrays in an impacted state Flashing N A On Green Enclosure ID setting different from start of day setting SES state S1 N A Flashing On N A Not ...

Страница 40: ...Cooling Module 0 PCM0 1 I O module 0 2 Power Cooling Module 1 PCM1 3 I O module 1 4 See Veritas 2U12 49TB Storage Shelf I O modules on page 40 See Veritas 2U12 49TB Storage Shelf Power Cooling Modules on page 44 See Power Cooling Module LEDs on page 45 Veritas 2U12 49TB Storage Shelf I O modules This section discusses the Veritas 2U12 49TB Storage Shelf I O modules 40 About the optional Veritas 2U...

Страница 41: ... table provides details of the two Veritas 2U12 49TB Storage Shelf I O module canisters Figure A 6 Veritas 2U12 49TB Storage Shelf I O modules 1 2 4 3 3 5 5 6 6 C B A C B A 4 7 41 About the optional Veritas 2U12 49TB Storage Shelf Components of the Veritas 2U12 49TB Storage Shelf ...

Страница 42: ...age 43 7 I O module Status LED location and conditions This section discusses the location of the Status LEDs on the I O module and the Status LED conditions Figure A 7 I O module Status indicator LED location I O module Status LED location Table A 6 I O module Status LED conditions Fault LED amber Activity LED green Condition The I O module has encountered a fault condition On Module Fault amber ...

Страница 43: ...AS Activity LEDs on the I O module and the SAS Activity LED conditions Figure A 8 I O module SAS Activity LED location SAS Activity LED location Table A 7 I O module SAS Activity LED conditions Fault LED amber Activity LED green Condition Off Off No Cable Present Off On Cable Present All links up no activity Off Flash with aggregate port activity Cable Present All links up On Off Critical Fault An...

Страница 44: ...B Storage Shelf I O modules on page 40 See I O module Status LED location and conditions on page 42 Veritas 2U12 49TB Storage Shelf Power Cooling Modules The Veritas 2U12 49TB Storage Shelf includes two Power Cooling Modules PCM The dual PCMs provide redundant power to the storage shelf If one PCM fails the storage shelf continues to operate as the second PCM continues to supply the storage shelf ...

Страница 45: ...e tab 3 AC power socket 4 Serial number located on the Power Cooling Module 0 tab Note The storage shelf serial number begins with the letters SH 5 Power Cooling Module LEDs Power Cooling Modules PCM use four LEDs to indicate the status of the PCM 45 About the optional Veritas 2U12 49TB Storage Shelf Components of the Veritas 2U12 49TB Storage Shelf ...

Страница 46: ...tions DC Fail Amber AC Fail Amber Fan Fail Amber Power Cooling Module OK Green Status Off Off Off Off No AC Power any Power Cooling Module On On Off Off No AC Power this Power Cooling Module only Off Off Off On AC Present Power Cooling Module On OK On Off Off On Power Cooling Module fan out of tolerance 46 About the optional Veritas 2U12 49TB Storage Shelf Components of the Veritas 2U12 49TB Stora...

Страница 47: ... Module fan fail On On On Off Power Cooling Module Fault Over temp over volts over current Off Off Off Flashing Standby Mode Flashing Flashing Flashing Off Power Cooling Module firmware download See Veritas 2U12 49TB Storage Shelf Power Cooling Modules on page 44 47 About the optional Veritas 2U12 49TB Storage Shelf Components of the Veritas 2U12 49TB Storage Shelf ...

Страница 48: ...B Storage Shelf 35 Veritas 2U12 49TB Storage Shelf 35 control panel Veritas 2U12 49TB Storage Shelf 37 control panel LED descriptions Veritas 2U12 49TB Storage Shelf 37 D disk drives 3U16 storage shelf 19 documentation 24 drive bay slot assignments Veritas 2U12 49TB Storage Shelf 35 F Fibre Channel card 18 FTMS configurations 17 ports 18 H hard disk drive capacities Veritas 2U12 49TB Storage Shelf...

Страница 49: ...ial number location 3U16 storage shelf 21 appliance 13 Veritas 2U12 49TB Storage Shelf 44 specifications environmental 32 Fibre Channel card 18 technical 29 standards compliance 33 storage capacity 9 storage shelf connecting to the appliance 21 rack post depth 31 using SAS cables 21 V Veritas 2U12 49TB Storage Shelf components 35 control panel 37 drive bay slot assignments 35 front panel component...

Отзывы: