Installation In struc tions

Hawkeye 8051/8053

PULSE OUTPUT kWH TRANSDUCERS

OPERATION

The H-8000 Series combines a microprocessor based kWh transducer and high ac-
curacy split-core in stru ment grade current transformers (CTs) in a single unit. Because 
the electronics are integral to the CT(s), hard ware and installation costs are greatly 
reduced. Split-core design eliminates the need to remove conductors.

local or remote 

electrical metering 

and submetering 

in commercial 

buildings!

P/N   Z101659-0D

                  10831 S.W. CASCADE BLVD. 

PORTLAND, OREGON 97223

(503) 598-4564   FAX (503) 598-4664

1-800-354-8556

VERIS INDUSTRIES

http://www.veris.com    email:[email protected]     

®

Applications

    Tenant submetering for commercial tenants

    Energy management & performance contracting

    Departmental costing in manufacturing facilities

    Cooling plant optimization

Easy cost-eff ective installation

    Precision transducer electronics and high accuracy instrument grade CT's in a single  

         easy to install package...reduces the num ber of installed com po nents

    Unique split-core design eliminates the need to remove conductors 

    Fits easily into distribution panels...lowest total installed cost

    Automatically detects phase reversal...eliminates the need to be concerned with CT load                     

 

         orientation

    Economical single-CT version available for balanced loads (H8051)

High accuracy and resolution

  

± 1% accuracy conforms to ANSI C12.1 metering standards (H8053)

    0.1 to 1.0 kWH/pulse selectable

• This product is not intended for life or safety applications

• Potential electrocution hazard exists.  Installing  sen sors in an en er gized electrical 
enclosure or on any en er gized con duc tor can be haz ard ous.  
•  Read instructions thoroughly prior to install
Severe injury or death can result from electrical shock during contact with high 
voltage conductors or related equip ment.  Dis con nect and lock-out all power 
sources during installation and service. Applications  shown are sug gest ed means 
of installing sensors, but it is the  re spon si bil i ty of the installer to ensure that the 
in stal la tion is in com pli ance with all national and local codes.  In stal la tion should 
be at tempt ed only by in di vid u als familiar with codes, stan dards, and proper safety 
pro ce dures for high-voltage installations.

WARNING--REFER SERVICING TO    
QUALIFIED PER SON NEL ONLY!