4: Using the Web Interface
60
Verint Video Intelligence Solutions
Configuring the Device
The following parameter categories are available for configuration on the device:
Configuring the Serial Port
The device has one serial port, RS-422/485, for communicating with serial equipment (for
example, PTZ cameras). For more information about the serial port settings of the specific
product with which you want to interface, refer to its user guide or contact your product
manufacturer.
To configure the serial port:
1. In the navigation pane, expand Configuration, then click Serial Port. The serial port
parameters appear.
2. In the Bit Rate box, enter the transmission speed of the target equipment. Possible
values range from 1200 to 230,400 bits per second.
3. In the Parity list, select the parity check. Parity is used for error detection. Possible
values are Odd, Even, or None.
4. In the RS-422/485 Operating Mode list, select the way the RS-422/485 equipment
will interface with the device. Possible values are RS-422 4 Wires, RS-485 4 Wires, and
RS-485 2 Wires.
5. In the Stop Bits list, select the number of stop bits in each transmission. Possible
values are 1 or 2 bits.