unclip the battery from its connector and put a new one put in its place.  Replace the 
cover. 

10

 

BURNER:  (see  figure  4)  Wait  until  the  fire  is  cold  before  attempting  to  change  these 
batteries  which  are  in  a  carrier  at  the  left  hand  side  of  the  burner.  Grip  the  separate 
piece of grille at the left hand side of the burner by inserting two fingers into the holes 
provided, tip forwards and lift the battery carrier out of the firebox. Remove the battery 
case from the carrier. Open the case by unscrewing the locking screw and remove the 
used  batteries.  Insert  four  new  Lithium  AA  batteries  observing  the  correct  polarity. 
Close the case and replace the screw. Place the battery case in the battery carrier and 
replace the whole assembly back into the appliance. 

Note

;  Replacement  AA  Lithium  batteries  are  available  from  Verine  Ltd.  Alkaline  batteries 

are not recommended for this application. 

Spare Parts List 

In the event of a part requiring replacement the parts list is as follows 

Part Description 

Part Number 

Electronic Control Box and 

Remote hand control 

G6R - P4S1A5 

GV60 Motorised valve 

GV60M1- C5D1H1L 

Oxypilot (NG models) 

OP9037 

Oxypilot (LPG models) 

OP9223 

Burner Control Battery 

Energiser 1.5 volt AA Size Lithium L91  

 

 

 

 
 
 

Содержание ATINA 500

Страница 1: ... THIS IS NOT A DO IT YOURSELF PRODUCT THE APPLIANCE MUST BE INSTALLED BY A GAS SAFE REGISTERED PERSON INSTALLATION SERVICING AND USERS INSTRUCTIONS THESE PRODUCTS ARE APPROVED TO THE EUROPEAN GAS DIRECTIVE PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER FOR FUTURE REFERENCE ...

Страница 2: ...nclude 4 off mounting screws and a pair of disposable gloves h Four Sided Trim Optional APPLIANCE DATA NABG50RN NVBG70RN NABG50RP NVBG70RP GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 6 2 kW Net 8 5kW Net 6 4 kW Net 8 1 kW Net INJECTOR SIZE Ø 1 9mm Ø 2 3mm Ø 1 31mm Ø 1 46 mm GAS CONNECTION 8 mm Compression WEIGHT 16kg 23kg 16kg 23kg GENERAL INSTALLATION REQUIREMENTS Fitting th...

Страница 3: ...al If an infill panel is to be used the firebox flange can either be on the outside of the panel and finished with a decorative trim or the flange can be set on the inside of the infill panel where a trim will not be required The size of the hole in the infill panel will vary depending on whether the flange is inside or outside The hole sizes required are shown in Figure 2 A trim will be required ...

Страница 4: ...lf or horizontal bar all made from non combustible material and fixed not less than 50mm not more than 1000mm above the floor level They should be positioned not less than 300mm in front of and 150mm beyond the edge of any naked flame or incandescent part of the fire bed 5 The Chimney Flue Both Appliances The chimney should be of the open flue type and have a minimum cross sectional dimension of n...

Страница 5: ... with a suitable material or low level venting must be installed If low level venting is installed this must not be connected to the main flueway as this will cause dilution and may well result in lack of flue pull through the appliance 1 Check that the fireplace is of the correct size or has been modified to accept the selected firebox See Figure 1 2 It is recommended that before proceeding furth...

Страница 6: ...the installation may be easier if the top part of the firebox is removed from the bottom to give better access to install the gas supply 9 Temporarily place the control mount in the lower part of the firebox and run the gas supply through one of the grommeted holes at the rear or bottom of the lower firebox and connect it to the gas inlet fitting IMPORTANT Ensure both grommets are fitted correctly...

Страница 7: ...the burner is placed in position without re placing the grille as the tube from the manometer can pass in front of the burner Please note that the flames from the burner ports will not all be of equal length FILLING THE BURNER Fill the burner tray level to the top with either the glass gravel black ceramic granules or limestone pebbles provided PLACING OF DECORATIVE REFRACTORY SHAPES 1 Decorative ...

Страница 8: ...imately 25mm higher push the frame back and then lower it gently so that the frame locates on the four mounting screws if the frame does not locate onto the screws remove the frame and very slightly increase the gap between the screw head and fire frame a large gap must be avoided as this will result in the frame being loose on the fire COMMISSIONING Before attempting to light the appliance the ga...

Страница 9: ...s any decorative ceramic shapes and the removal of soot as described in these instructions 2 Inform the customer that all cleaning procedures should be carried out only when the appliance is cold 3 Leave these instructions with the customer 4 Advise the importance of having the appliance serviced and the chimney checked for clearance of combustion products on an annual basis ...

Страница 10: ...UMSTANCES should they be washed 6 Never throw cigarette ends or other foreign matter onto the fire 7 Never leave the house unattended with the fire alight for long periods 8 Check periodically that any purpose made ventilation is free from obstruction 9 To obtain the best results from your fire we recommend that it be serviced annually 10 These instructions are provided to assist you to operate th...

Страница 11: ...r on the handset until the fire control box answers with a beep The fire will go through its start up procedure by lighting first the pilot burner and then the main burner on high fire This procedure takes about 30 seconds During this process the fire will emit a regular series of beeps If the fire does not light or there is no reaction when the two buttons are pressed press the OFF button to re s...

Страница 12: ...isolator fitting Disconnect the control mount from the gas supply and lift it out of the lower firebox 3 Empty the glass gravel from the burner on to a clean surface and thoroughly clean the burner ports 4 The pilot burner fitted is an oxygen depletion pilot burner and is the primary safety device on the appliance It must therefore be replaced annually After changing the pilot burner operate the s...

Страница 13: ...cking screw and remove the used batteries Insert four new Lithium AA batteries observing the correct polarity Close the case and replace the screw Place the battery case in the battery carrier and replace the whole assembly back into the appliance Note Replacement AA Lithium batteries are available from Verine Ltd Alkaline batteries are not recommended for this application Spare Parts List In the ...

Страница 14: ...RVICE Serviced by GAS SAFE No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by GAS SAFE No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by GAS SAFE No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by GAS SAFE No Service Date Signed Comments RECORD OF 6th SERVICE Serviced by GAS SAFE No Service Date Signed Comments RECORD OF 7th SERVICE Serviced by GAS SAF...

Страница 15: ... Issue 3 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com THIS BOOKLET CONTAINS 15 PAGES ATINA VERTEX 1007 II UI ...

Отзывы: