Cleaning the Inlet

If the inlet is blocked by dust, completely remove the foreign materials – after fi rst 
turning the vacuum OFF.

A blocked inlet may result in weakened suction and noise. If the inlet is blocked, 
there is also a risk of damage or malfunction caused by overheating.

Care and Maintenance

Figure 3

Figure 4

Emptying Dust Container and 
Cleaning Filters

1.

  Disconnect the cleaner from the base 

section by pressing the release lever 
at the rear of the cleaner and lifting 
up.

2. 

Press the dust container lock button 
to release the dust container from the 
vacuum. (See Figure 3) 

3.

  Carefully pull the fi lter assembly 

outward and remove.

4. 

Empty the container. (See Figure 4)

5. 

Unlock the outer fi lter by twisting it 
slightly to the right (clockwise).

6. 

Remove the outer fi lter by pulling it 
away from the main casing.

7. 

Pull the inner fi lter out to remove.

8. 

The fi lters should be cleaned every 
time the dust container is emptied by 
tapping them on the side of the bin to 
release trapped dust. 

9. 

Wash both fi lters in lukewarm water 
on a regular basis.

10. 

Make sure the fi lters are completely 
dry before reassembly.

11.

 Reassemble in the reverse order.

Содержание CleanWave

Страница 1: ...VH07 ...

Страница 2: ...her healthy lighting products are available through our catalog and online Visit us on the web at www Verilux com to request a free catalog and learn more about all our quality Verilux products or call our toll free number 1 800 786 6850 As a Verilux customer your satisfaction means everything to us We look forward to serving you now and in the future Have a bright day Nicholas Harmon President Ve...

Страница 3: ...izing Furniture Bed Vac Features 7 Description of Functions 7 Initial Set up 8 Vacuuming with UV C 8 Using the Hand Vacuum Only 8 Mattress Bedding Cleaning Guidelines 9 Care and Maintenance 10 Cleaning the UV C Bulb 11 Replacing the UV C Bulb 12 Troubleshooting 13 Safety Switches 13 Technical Specifications 14 Warranty 15 ...

Страница 4: ...s blocked keep free of dust lint hair and anything that may reduce air flow Keep hair loose clothing fingers and all body parts away from openings and moving parts Do not vacuum anything that is burning or smoking such as cigarettes matches or hot ashes Turn off vacuum before unplugging Use extra care when cleaning on stairs Do not use to vacuum flammable or combustible liquids such as gasoline or...

Страница 5: ...are should be taken to prevent bulb breakage No one individual should use this product more than one hour per day without ear protection Always turn off this appliance before connecting or disconnecting the base WARNING This product contains a chemical known to the state of California to cause birth defects or other reproductive harm CAUTION UV C light may degrade plastic and rubber over time WARN...

Страница 6: ...me anywhere vacuum As a bed vacuum the combination of powerful suction and UV C light quickly removes dust and dirt while eliminating up to 99 9 of viruses bacteria dust mite eggs and dust mite waste a common cause of colds allergic reactions and asthma Allergens due to mold and dust mites Instruction manual Handheld vacuum cleaner with dirt container and dual filters Base unit with UV C bulb Nozz...

Страница 7: ...leaner Easy to empty dirt container No messy bags Dual filters Micro fiber filter captures large particles HEPA filter traps pollen and microscopic allergens as small as 0 3 microns with 99 97 efficiency Only clean air is expelled back into the room Removes odors and dangerous allergens including those that can cause pneumonia asthma and other conditions Allergens due to mold and dust mites CleanW...

Страница 8: ... picked up the filters dust container and tools must be thoroughly cleaned immediately after use CAUTION Direct exposure to UV C light can cause serious skin burn and eye inflammation from short wave ultraviolet radiation Radiation from this bulb is harmful to the eyes and skin CAUTION Do not override the safety switches manually CAUTION Do not attempt to pick up large or sharp objects as these ma...

Страница 9: ...attress Move the vacuum in a smooth and steady motion To make sure that every part of the mattress is exposed follow a predetermined pattern With double or larger beds clean one side of the bed at a time If possible clean both sides of the mattress With a used mattress clean on a daily basis for seven days then as much as once a week at the least once a month With a new mattress once a month clean...

Страница 10: ...nd lifting up 2 Press the dust container lock button to release the dust container from the vacuum See Figure 3 3 Carefully pull the filter assembly outward and remove 4 Empty the container See Figure 4 5 Unlock the outer filter by twisting it slightly to the right clockwise 6 Remove the outer filter by pulling it away from the main casing 7 Pull the inner filter out to remove 8 The filters should...

Страница 11: ...container and clean the filters regularly If this is not done the cleaner will lose its effectiveness We recommend that you empty and clean the vacuum after each use Cleaning the UV C Bulb During use dust may collect on the protective cover and the UV C bulb which will reduce the effectiveness of the UV C light For maximum UV C exposure clean the bulb periodically 1 Detach the protective grill on ...

Страница 12: ...se unit by pulling up the two tabs at the back of the covering Set the cover aside See Figure 5 2 Remove the two plastic pieces that cover the ends of the UV C bulb 3 Unscrew the screws surrounding the protective housing 4 Using a small pair of pliers at one end of the bulb rotate the bulb 90 degrees and remove See Figure 6 Note UV C bulb is housed in a glass sleeve to protect it from accidental d...

Страница 13: ...rs not covered Sensor switches only operate when the base is level and in contact with the surface being cleaned Safety Switches The UV C light will only turn on when the vacuum cleaner is facing downward and in contact with the surface being cleaned On the bottom of the base unit there is pressure sensitive wheel The wheel is activated when it contacts a cleaning surface Three additional sensors ...

Страница 14: ...t UV C bulb replace with Verilux Model Number VH07RB1 only UV C Peak Wavelength 254 nanometers Power Input Power AC 120V 60Hz 400 Watts Weight 4 98 pounds Warning This product contains a chemical known to the state of California to cause birth defects or other reproductive harm This device complies with the appliance efficiency regulations laid down by the California Energy Commission ...

Страница 15: ...VH07 MAN Rev8 Please visit our web site at www Verilux com 340 Mad River Park Waitsfield VT 05673 Printed in China for Verilux Inc Copyright 2009 Verilux Inc All rights reserved ...

Отзывы: