Verilux CleanWave VH04WW1 Скачать руководство пользователя страница 28

VH04-MAN-2012-WEB

Printed in China for Verilux, Inc.  

© Copyright 2012 Verilux, Inc. All rights reserved.

ATTENTION! ONCE OPENED, PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE WHERE IT WAS 

PURCHASED FOR REPAIR OR REPLACEMENT!

Many questions may be answered by visiting www.verilux.com, or you may call our Customer Service Department at  

800-786-6850 during normal business hours.
This limited warranty is provided by: Verilux, Inc., 340 Mad River Park, Waitsfield, VT 05673

Covered By This Warranty

Verilux warrants this product when used and maintained 

in normal household use and in accordance with the 

Owner’s Manual to be free from original defects in material 

and workmanship for a period of one year from the date of 

the original retail purchase (the “Limited Warranty Period”) 

from Verilux or an authorized Verilux distributor. During 

the limited warranty period, Verilux, Inc., will, at its option, 

repair or replace defective parts of this product, at no 

charge to the customer, to correct any such defects.

Not Covered By This Warranty

This warranty does not cover the brush roll, drive belt, 

UV-C bulb, motor brushes, wheels or the filters. This 

warranty does not include any postage, freight, handling, 

insurance, or delivery fees. This warranty does not cover 

damage, defect or failure caused by or resulting from 

accident, external destruction, alteration, modification, 

abuse, misuse or misapplication of this product. This 

warranty does not cover damage to the product 

resulting from return shipping or handling. Verilux advises 

purchasing shipping insurance to protect your investment 

in the product.

Additional Warranty Terms

This warranty is non-transferable and may not be 

assigned. The Limited Warranty Period will not be 

extended by any replacement or repair performed under 

this warranty. 
THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND 

REMEDY, ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR PARTICULAR 

PURPOSE, ARE DISCLAIMED, IN NO EVENT WILL 

VERILUX BE LIABLE FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES OF 

ANY KIND OR NATURE TO OWNER OR ANY PARTY 

CLAIMING THROUGH OWNER, WHETHER BASED 

IN CONTRACT, NEGLIGENCE, TORT OR STRICT 

PRODUCTS LIABILITY OR ARISING FROM ANY CAUSE 

WHATSOEVER. Some states do not allow the exclusion of 

consequential damages, so the above exclusion may not 

apply to you. This warranty gives you specific rights; you 

may also have others that vary from state to state.

Making A Warranty Claim
Proof of purchase is required for all warranty claims. 

Return Authorization is required for all returns. 

To 

obtain a Return Authorization, please contact the Verilux 

Customer Service Department at 800-786-6850.
If, during the first year of ownership, this product fails to 

operate properly, it should be returned as specified at 

www.verilux.com/warrantyreplacement or as instructed by 

a Verilux customer service representative at  

800-786-6850.
Due to ongoing improvements, the actual product may 

have slight variations from the one described in this 

manual.

Please visit our website at www.verilux.com or call our Customer Service Department at

1-800-786-6850

Representatives are available Monday — Friday, 9:00a.m. to 5:00p.m Eastern Time

Do not return product for warranty claim without a Return Authorization number.

9. One-Year Limited Warranty

VH04-MAN-2012_Web.indd   28

12/12/12   3:37 PM

Содержание CleanWave VH04WW1

Страница 1: ...n exposure of UV C light to bed bug eggs viruses and bacteria in the laboratory under controlled conditions May be less effective when used on pile carpets and certain fabric surfaces UV C effectivene...

Страница 2: ...5 HEPA 12 Exhaust Filter 21 7 6 Replacement Filters 21 7 7 Cleaning and Replacing the Sanitizing Light Bulb 22 7 8 Sanitizing Light Bulb Disposal 23 7 9 Replacement Parts 24 7 9a b Replacing the Whee...

Страница 3: ...d may burn Do not use with damaged cord or plug Do not use vacuum if it has been dropped damaged left outdoors or dropped in water DO NOT point the vacuum cleaner directly at your or anyone s face The...

Страница 4: ...ng such as cigarettes matches or hot ashes Turn off vacuum before unplugging Use extra care when cleaning on stairs Follow all labels and instructions Store the vacuum cleaner indoors Put the vacuum c...

Страница 5: ...6850 or visit www verilux com Dispose of bulbs per local regulations For more information on clean up and disposal see www lamprecycle org continued CAUTION Direct prolonged exposure of eyes or skin...

Страница 6: ...lergens without chemicals or liquids Safely sanitizes surfaces without irritants or residues Laboratory proven to eliminate up to 99 of H1N1 and MRSA in 1 second Specially designed floor sensor safety...

Страница 7: ...oved before recycling the packaging material 1 Sanitizing Power Head 2 Vacuum Canister 3 Handle and Hose 4 Telescoping Wand 5 Crevice Tool Dusting Brush and Upholstery Tool 6 Spare Power Head Rear Whe...

Страница 8: ...able Power Cord 6 Cord Rewind Button 7 Dirt Cup 8 Release Latch 9 Canister Inlet 10 Canister Power Receptacle 11 Sponge Filter 12 HEPA 12 Pre Filter 13 Cone Filter 14 HEPA 12 Exhaust Filter 15 Filter...

Страница 9: ...es continued 4 2 Handle and Hose 1 Power Head ON OFF Switch 2 Airflow Selector 3 Wand Coupler 4 Hose Power Plug 5 Canister Coupler 6 Release Button 1 2 3 3 4 4 5 6 4 2 VH04 MAN 2012_Web indd 9 12 12 1...

Страница 10: ...or 4 Syphon Receptacle 5 Syphon Release 6 Headlight 7 Sanitizing Light Bulb 8 Bulb Cover 9 Floor Sensor safety switch 10 Powered Brush Roll 11 Squeegee 12 Bulb Cover Release Tabs 13 Rear Wheels 14 Sta...

Страница 11: ...2 Release Button 3 Release Cuff 4 Sanitizing Power Head Coupler 4 5 Accessories 1 Crevice Tool 2 Dusting Brush 3 Upholstery Tool 4 6 Power Head Spare Parts 1 Rear Wheels 2 2 Stand up Locks 2 1 2 3 3 2...

Страница 12: ...ch of the Canister Coupler A with the Canister Inlet B and push until the latch clicks To disconnect press the Release Button C on the Canister Coupler A and pull out 2 Insert the Hose Power Plug D in...

Страница 13: ...escoping Wand grab the Release Cuff D and push it forward to extend the wand and pull it back to contract the wand 5 2 5 3 5 3 Connecting the Sanitizing Power Head 1 Align the Sanitizing Power Head Co...

Страница 14: ...ical outlet 6 2 Cord Release Rewind 1 Pull on the Power Cord B to unwind to desired length and insert the plug into a convenient electrical outlet The yellow mark on the Power Cord B shows the typical...

Страница 15: ...1 Power Head ON OFF Button C Press to turn the Sanitizing Power Head on and off 2 Airflow Selector D Slide the Airflow Selector to the open position to reduce suction when cleaning delicate fabrics 6...

Страница 16: ...Off On Sanitizing Light Suction Both Purple On On On Sanitizing Light Powered Brush Roll Suction Surface Protection Sanitizer Deodorizer Mode Blue Both Mode Purple slow blinking Off Sanitizer Deodori...

Страница 17: ...icator will not be illuminated turns off Both Mode Brush and Sanitizer Deodorizer Modes Simultaneously Select the Both Mode when you want to engage the Sanitizing Light as well as the Powered Brush Ro...

Страница 18: ...Wand Crevice Tool Use the crevice tool in tight spaces corners or along edges such as baseboards and stairs You can use this tool in drawers cupboards and upholstery Dusting Brush Select the dusting b...

Страница 19: ...nd clean the Cone Filter E by rotating counter clockwise and pulling out If desired rinse with water dry completely and replace Cone Filter E by inserting and rotating clock wise to lock 5 Close the L...

Страница 20: ...acing any filters disconnect Power Cord from electrical outlet 7 3 HEPA 12 Pre Filter The HEPA 12 Pre Filter B is located outside dirt cup C 1 Remove the Dirt Cup C by lifting up on the Release Latch...

Страница 21: ...A 12 Exhaust Filter A is located under the Filter Access Panel B on the back of the canister 1 Remove the the HEPA 12 Exhaust Filter A by lifting up on the Access Panel Tabs C 2 Grasp the filter by th...

Страница 22: ...h the Powered Brush Roll C closest to you 2 With one hand depress one Bulb Cover Release Tab D by pulling it toward the Powered Brush Roll C 3 With the other hand grasp the Squeegee E near the Bulb Co...

Страница 23: ...t Bulb A away from the Power Head B 7 Gently grasp the Sanitizing Light Bulb A and remove from Bulb Socket 8 Wipe Sanitizing Light Bulb A and Reflector clean with a soft dry cloth 9 To re install the...

Страница 24: ...Your CleanWave is designed with rubber locks to allow the wand to remain upright when desired To remove a lock press your thumb on the base of the lock push up and pull out as the lock is removed fro...

Страница 25: ...Cap VH04RB1 14 95 Bulb Cover Kit Bulb Cover Grill Squeegee VH04BC1 9 95 Attachment Kit Crevice Tool Dusting Brush Upholstery Tool VH04AK1 9 95 Filter Kit HEPA 12 Pre Filter HEPA 12 Exhaust Filter Spo...

Страница 26: ...electrical outlet or contact a licensed electrician N A Power cord not securely plugged in Plug power cord securely in wall electrical outlet 6 2 Poor Suction Canister Sanitizing Power Head Filter s a...

Страница 27: ...izing Power Head is stationary Push Sanitizing Power Head back and forth If the Sanitizing Power Head is stationary for five or more seconds the Sanitizing Light Bulb will turn off 6 6 Floor Protectio...

Страница 28: ...e product Additional Warranty Terms This warranty is non transferable and may not be assigned The Limited Warranty Period will not be extended by any replacement or repair performed under this warrant...

Отзывы: