6
7
Basic functionality
POWER ON/OFF
To turn thermostat on or off press “
”
SELECT HOW TO CONTROL YOUR FLOOR HEATING SYSTEM
Your Veria floor heating system can be controlled either by the:
•
Floor temperature - program mode 2
The heating element turns on/off around a floor temperature
setpoint (the temperature shown in the display is the actual
floor temperature)
•
Room temperature - program modes 1 & 4
The heating element turns on/off around a room temperature
setpoint (the temperature shown in the display is the actual
room temperature)
•
Combined floor and room temperature - program modes
3 & 5
The heating element turns on/off around a room tempera
-
ture setpoint with a requested max. floor temperature (floor
temperature is prioritized over room temperature)
Change between the above floor heating modes:
With the thermostat turned off.
Press
“
” and
“ ” for 6 seconds
Select mode 1 to 5 (see table on next page)
After choosing the desired mode do not press any further buttons and
the thermostat will go back to normal standby mode.
Basic functionality
RECOMMENDED SETTINGS
Veria recommends the following settings for different type of floor
constructions:
Top flooring
Program mode
Wooden
floor*
Tiled
floor**
1
(room sensor)
If total effect: 0W-1840W
x
2
(floor sensor)
If total effect: 0W-2990
W
x
x
3
(combined floor and room sensor)
If total effect: 1840W-2990
W
x
x
4
(room sensor)
If total effect: 1840W-2990
W
x
5
(combined floor and room sensor)
If total effect 0W-1840W
x
x
* Top flooring made of parquet, laminate, massive wood, carpet,
linolium or the like.
** Top flooring of tiles, concrete, marble or the like.
EN