2. Mounting Instructions
Please follow the below guidelines when installng the ther
-
mostat
Place the thermostat at a suit
-
able height on the wall (typi
-
cally 80-170cm)
In wet rooms, place the thermo
-
stat according to local regula
-
tion on IP classes.
Plaats de thermostaat niet aan
de binnenzijde van een buiten
-
muur.
A floor sensor enables a more ac
-
curate temperature control and is
recommended in all floor heating
applications and mandatory un
-
der wooden floors to reduce the
risk of over-heating the floor.
•
Place the floor sensor in a
conduit in an appropriate
place where it is not ex
-
posed to sunlight or draft
from door openings.
•
Equally distant and >2cm
from two heating cables.
•
The conduit should be
flush with the floor surf
-
ace - countersink the con
-
duit if necessary.
•
Route the conduit to the
connection box.
•
The bending radius of
the conduit must be min
50mm.
Avoid placing the thermostat in
direct sunlight
2.
Mounting Instructions
2.
Mounting Instructions