2. Mounting Instructions

Please follow the below guidelines when installng the ther

-

mostat

Place the thermostat at a suit

-

able  height  on  the  wall  (typi

-

cally 80-170cm)

In wet rooms, place the thermo

-

stat  according  to  local  regula

-

tion on IP classes.

Plaats de thermostaat niet aan 
de binnenzijde van een buiten

-

muur.

A floor sensor enables a more ac

-

curate temperature control and is 
recommended in all floor heating 
applications  and  mandatory  un

-

der wooden floors to reduce the 
risk of over-heating the floor.
• 

Place the floor sensor in a 
conduit in an appropriate 
place  where  it  is  not  ex

-

posed to sunlight or draft 
from door openings.

• 

Equally distant and >2cm 
from two heating cables.

• 

The  conduit  should  be 
flush with the floor surf

-

ace - countersink the con

-

duit if necessary.

• 

Route the conduit to the 

connection box.

• 

The  bending  radius  of 
the  conduit  must  be  min 

50mm.

Avoid placing the thermostat in 
direct sunlight

2.

 Mounting Instructions

2. 

Mounting Instructions

Содержание Control B35

Страница 1: ...Veria Control B35 B45 Installation guide...

Страница 2: ...op of wood floors such as parquet or laminates The Veria Control B45 Thermostat can be used for temperatures up to 45 C which makes it ideal for controlling electrical heating mats on top of concrete...

Страница 3: ...rned off before installation IMPORTANT When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material always use a floor sensor and never set the...

Страница 4: ...is recommended in all floor heating applications and mandatory un der wooden floors to reduce the risk of over heating the floor Place the floor sensor in a conduit in an appropriate place where it i...

Страница 5: ...rate connector Note Always install the floor sensor in a conduit in the floor 3 Mount and reassemble the thermostat Fasten the thermostat to a socket or an exterior wall box by driving the screws thro...

Страница 6: ...the following The floor temperature is measured where the floor sensor is placed The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top Floor manufactures often s...

Страница 7: ...ectrical specialist If the defect is caused by an unsuitable or poor floor construction In addition guarantee claims will only be honoured if the atta ched guarantee certificate is completed properly...

Страница 8: ...14 15 Notes Notes...

Отзывы: