![VERDER VERDERAIR VA-E25 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/verder/verderair-va-e25/verderair-va-e25_operation_1003776022.webp)
Torque
Torque
Torque Instructions
Instructions
Instructions
If fluid cover or manifold fasteners have been
loosened, it is important to torque them using the
following procedure to improve sealing.
NOTE:
NOTE:
NOTE: Fluid cover and manifold fasteners have a
thread-locking adhesive patch applied to the threads.
If this patch is excessively worn, the fasteners may
loosen during operation. Replace screws with new
ones or apply medium-strength (blue) Loctite or
equivalent to the threads.
NOTE:
NOTE:
NOTE: Always completely torque fluid covers before
torquing manifolds.
1.
Start all fluid cover screws a few turns. Then, turn
down each screw just until head contacts cover.
2.
Turn each screw by 1/2 turn or less working in a
crisscross pattern in the order shown to specified
torque.
3.
Repeat for manifolds.
Fluid
Fluid
Fluid cover
cover
cover and
and
and manifold
manifold
manifold fasteners:
fasteners:
fasteners: 10.2 N•m
(90 in-lb)
Fluid
Fluid
Fluid Cover
Cover
Cover Screws
Screws
Screws
Inlet
Inlet
Inlet and
and
and Outlet
Outlet
Outlet Manifold
Manifold
Manifold Screws
Screws
Screws
22
859.0510
Содержание VERDERAIR VA-E25
Страница 29: ...Dimensions typical only Figure 10 Pumps with Aluminum Fluid Sections with Compressor 859 0510 29 ...
Страница 31: ...Dimensions typical only Figure 11 Pumps with Polypropylene Fluid Sections without Compressor 859 0510 31 ...
Страница 32: ...Dimensions typical only Figure 12 Pumps with Polypropylene with Compressor 32 859 0510 ...
Страница 34: ...Dimensions typical only Figure 13 Pumps with Stainless Steel Fluid Sections without Compressor 34 859 0510 ...
Страница 35: ...Dimensions typical only Figure 14 Pumps with Stainless Steel Fluid Sections with Compressor 859 0510 35 ...