4
859.0089
ATEX Certifications
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. When
these symbols appear in the body of this manual, refer back to these Warnings. Additional, product-specific warnings
may be found throughout the body of this manual where applicable.
★
All
VA25A
(Aluminum) and
VA25C
(Conductive Polypropylene)
pumps are certified:
II 2 GD c IIC T4
‡
VA25S
(Stainless Steel) pumps
with aluminum or conductive poly-
propylene centers are certified:
II 2 GD c IIC T4
II 1 G
EEx ia IIA T3
Nemko06ATEX1124
✖
Pulse Count is certified:
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in
work area
can ignite or explode. To help prevent
fire and explosion:
•
Use equipment only in well ventilated area.
•
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•
Keep work area free of debris, including solvent, rags and gasoline.
•
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•
Ground all equipment in the work area. See
Grounding
instructions.
•
Use only grounded hoses.
•
Hold gun firmly to side of grounded pail when triggering into pail.
•
If there is static sparking or you feel a shock,
stop operation immediately.
Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable
materials and gases. To help prevent fire and explosion:
•
Clean plastic parts in a well ventilated area.
•
Do not clean with a dry cloth.
•
Do not operate electrostatic guns in equipment work area.