![VERDER HI-CLEAN VA-2H40 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/verder/hi-clean-va-2h40/hi-clean-va-2h40_repair-parts_1003755013.webp)
Disassemble
Disassemble
Disassemble Flapper
Flapper
Flapper Check
Check
Check Valves
Valves
Valves
1.
Follow the
Pressure Relief Procedure, page 9
Disconnect all fluid and air lines.
2.
To drain the pump, pull the frame quick-release
pins (207) and rotate the pump.
NOTE:
NOTE:
NOTE: After draining, rotate the pump to
positions which will aid disassembly.
3.
Remove the clamps (23) on the outlet manifold
(17) and remove the manifold.
NOTE:
NOTE:
NOTE: Use care while removing manifolds to
avoid damage to check valve components.
4.
Remove remaining clamps (23), manifolds (16
and 17), gaskets (18), and check valves (8).
5.
Clean and inspect gaskets, flappers, and
seating surfaces for any damage and replace as
necessary.
6.
To continue with diaphragm disassembly, see
Disassemble the Standard Diaphragms, page 14
.
Reassemble
Reassemble
Reassemble the
the
the Check
Check
Check Valves
Valves
Valves
NOTE:
NOTE:
NOTE: Lubricate clamps, clamping surfaces, and
gaskets with waterproof, sanitary lubricant.
1.
Reassemble check assembly in reverse order.
2.
Attach the manifolds to the fluid covers. Tighten
clamps hand tight.
812.0064
13