RAID 0

 

(Also called Striping) distributes data across both disks in a way which 
can improve throughput, while retaining full capacity. However, in case 
of possible failure of either disk, all data will be lost and the array will 
no longer mount to your computer. Available capacity is the combined 
capacity of both drives.

If either disk fails in RAID 0 then the LED of the failed drive will change 
to RED.

RAID 1

 

(Also called Mirroring) stores a duplicate set of data onto both disks, so that 
if one disk fails all data can be recovered from the other disk. 
Available capacity is equal to that of only one of the two included drives.

If either disk fails in RAID 1, then the LED corresponding to the failed disk 
will change to RED. The remaining operational disk can continue to be used 
until the failed disk has been replaced. However, in this instance there is no 
longer any data protection provided by the second, failed drive.

If you have been using RAID 1 mode and there is a subsequent failure of 
either of the two drives, you can disassemble the enclosure and replace 
the failed drive with a new drive. After reassembling the enclosure, leave it 
disconnected from your computer and power it up. When the new drive is 
detected during the power-on sequence, the full data of the original drive 
will be rebuilt onto the new drive. This rebuilding procedure can take many 
hours (more than 5!) to complete. During the rebuilding procedure, the 
LED of the original good drive will fl ash BLUE, while the LED of the new 
replacement drive will fl ash RED. After the array has rebuilt successfully 
both LEDs will change to BLUE.

Concatenation

 

(RAID Mode Switch Setting = “BIG”) combines both physical disk drives 
into a single virtual disk. Available capacity is the combined capacity of 
both drives.

This mode provides no data redundancy. If either disk fails in Concatenation 
mode, then the array will no longer mount to your computer.

If either disk fails in Concatenation mode, then the LED corresponding to 
the failed disk will change to RED.

Содержание 2-Disk RAID USB and eSATA External Hard Drive

Страница 1: ...1 2 Disk RAID USB and eSATA External Hard Drive User Guide English...

Страница 2: ...Rear Panel Area 5 About the Hard Drives 6 Locating the Drive on your desk 6 Connecting to your computer 6 Con guring the RAID Mode 7 Disconnecting your Hard Drive 11 For Windows Users 11 For Mac OS U...

Страница 3: ...For example your PC hard drive The Verbatim 2 Disk RAID External Hard Drive comes with a factory default setting of Concatenation also called Spanning The switch setting for Concatenation mode is labe...

Страница 4: ...nel Area The front panel contains two multicoloured LEDs that show through a single lens as illustrated below During the power on sequence both LEDs will ash BLUE When the power sequence completes nor...

Страница 5: ...off the drive press the ON OFF button again USB Connector Use this connector to attach the drive to your 2 computer via USB eSATA Connector Use this connector to attach the drive to your 3 computer vi...

Страница 6: ...nts Connecting to your computer This Verbatim external hard drive provides both USB 2 0 and eSATA connections You can connect your drive to a computer with either USB or eSATA but not both at the same...

Страница 7: ...y partition the drive into smaller FAT32 partitions or you may reformat the drive to HFS format Note 4 eSATA Though the eSATA interface standard provides for hot plugging of the drive some computers m...

Страница 8: ...nd failed drive If you have been using RAID 1 mode and there is a subsequent failure of either of the two drives you can disassemble the enclosure and replace the failed drive with a new drive After r...

Страница 9: ...econ gured though remains initialised unpartitioned and unformatted Attach the drive to your host computer using either USB or eSATA 4 Your computer may show it as an unknown device which con rms that...

Страница 10: ...name into the box marked Volume Label and then click on Format Drive You will then see the message below asking you to con rm that you are about to format the selected drive If you proceed all data wi...

Страница 11: ...mply unplugging the unit without rst following the instructions below may result in damage to your unit and or loss of data For Windows Users If you have les located on your drive open in any applicat...

Страница 12: ...ies call 353 61 226586 Limited Warranty Terms Verbatim Limited warrants this product to be free from defects in material and workmanship for a period of 2 years from date of purchase This warranty exc...

Страница 13: ...tion points please contact your local municipal household waste disposal service or shop from where you purchased the equipment FCC Compliance This equipment has been tested and found to comply with t...

Страница 14: ...uirements of Council Directive 89 336 EEC and its amendments on the approximation of the laws of the Member States relating to electromagnetic compatibility This declaration applies to all specimens m...

Страница 15: ...is in compliance with Directive 2002 95 EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic e...

Отзывы: