background image

Support for sending Z-Wave Commands 

Z-Wave commands can be sent using the Vera API which will allow 
you to send HTTP requests with the specified command class to the 
specified node.
More details can be found on our wiki page.

http://wiki.mios.com/index.php/Luup_UPnP_Variables_and_Actions# 
ZWaveNetwork1

To send a Z-Wave command you’ll need to add the node id of the 
controlled Z-Wave device and the command class used.
For example to control node 3 and send a BASIC_SET with a value 
of 00, the command will be :
 
http://

GATEWAY_IP

/port_3480/data_request?id= 

action&DeviceNum=1&serviceId=urn: 
micasaverde-com:serviceId:ZWaveNetwork1&action= 
SendData&

Node

=3&

Data

=0x20-0x01-0x00

GATEWAY_IP

 is the actual local IP address of the unit. 

Node

 is the Z-Wave node the command is sent to. 

Data

 will contain the Z-Wave Command Class sent to the device.

Advanced Z-Wave Functions

Basic Command Class Handling

 

The basic command class is controlled by Vera and it is not mapped 
to any other Z-Wave Command Class.
More details can be found on our wiki page. 

http://wiki.mios.com/index.php/ZWave_Basic_Command_Class_Mapping

Support for Association Command Class

 

VeraPlus has support for the Lifeline association command class. 
 
group id: 1 - lifeline 
number of nodes in group: 1
 
More details can be found on our wiki page.

http://wiki.mios.com/index.php/Association

Support for Multiple Manufacturers in The Same Network 

The controller can be included and operated in any Z-Wave network 
with other certified Z-Wave devices from other manufacturers and/or 
other applications.  All non-battery operated nodes within the network 
will act as repeaters regardless of the vendor to increase the reliability 
of the network.

Содержание veraplus

Страница 1: ...d of convenience and peace of mind VeraPlus Controller AC Power Adapter Ethernet Cable In this package you ll find Back Front Detail Views Power Internet Wi Fi Z Wave Service Congratulations ZigBee Bluetooth 1 2 3 4 5 6 7 Power Ethernet USB Sync Reset Select Advanced Home Controller VeraPlus ...

Страница 2: ...to VeraPlus and plug it into an AC outlet VeraPlus has no on off switch It will power up as soon as you plug in the AC adapter 3 If you are a new user click the I have a new controller button on the screen Agree to the terms and conditions Then select your Controller If you already have an account please login Click the Add another controller button Then select your Controller Follow the Setup Ins...

Страница 3: ......

Страница 4: ... stringent Vera Labs testing for compatibility and quality The Custom Device Wizards make Inclusion Exclusion easiest with specific details for each device A list of these devices is available and updated at http getvera com compatibility For all other Z Wave devices a Generic Device Wizard is used for Inclu sion Exclusion A Generic Device Wizard is available for each device category thermo stats ...

Страница 5: ...o add the device After adding a new device the VeraPlus Controller will ask you to name it and choose the room it is or will be located in Note If the device was previously included with a different Z Wave system you ll need to it exclude it before adding with your VeraPlus You may also need to do this if you have problems Inclusion Exclusion the first time Press the Retry button to start the excl...

Страница 6: ...w the steps in the Device Wizard to add the device After adding a new device the VeraPlus Controller will ask you to name it and choose the room it is or will be located in Note If the device was previously included with a different Z Wave system you ll need to it exclude it before adding with your VeraPlus You may also need to do this if you have problems Inclusion Exclusion the first time Press ...

Страница 7: ...of Z Wave devices you do NOT need to use these buttons These instructions are for manually starting Z Wave Include and Exclude Modes Figure 2 1 Press the Select button Press the Select button again The Z Wave light will begin blinking For Include Mode press the Sync button briefly less than 1 second For Exclude Mode press and hold the Sync button for at least 2 seconds then release Controller Rese...

Страница 8: ...ab Figure 3 1 From there you ll be able to access these Advanced Z Wave options Advanced Z Wave Functions Figure 3 1 Advanced Tab Reset Z Wave network Will clear all the user configuration data and assign a new Z Wave HouseID Copy Z Wave network from a primary controller Will allow the unit to copy all Z Wave related information from a Primary Z Wave Controller and is used with Replication Control...

Страница 9: ... an existing Z Wave network Steps for VeraPlus controller using the web interface Click on Settings Z Wave Settings Advanced Select Copy Z Wave network from a primary controller This will put the controller into learn mode and shift it to a sec ondary role The controller can now receive data from a primary device in the network and associate with other devices in the Z Wave network via the primary...

Страница 10: ...e node the command is sent to Data will contain the Z Wave Command Class sent to the device Advanced Z Wave Functions Basic Command Class Handling The basic command class is controlled by Vera and it is not mapped to any other Z Wave Command Class More details can be found on our wiki page http wiki mios com index php ZWave_Basic_Command_Class_Mapping Support for Association Command Class VeraPlus...

Отзывы: