![Veolia Hydrotech Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/veolia/hydrotech/hydrotech_appendix_1003050006.webp)
Appendix, Hydrotech
Drumfilter
HPC
5.
Push
the
slide
block
to
the
service
recess
and
lift
out
the
slid
block
from
the
profile
beam.
6.
Measure
the
inner
position
of
the
actuator.
The
below
example
shows
the
measurement
30mm.
Remark:
The
actuator
have
a
maximum
stroke
of
100mm
and
it
is
important
that
the
actuator
stroke
is
adjusted
so
that
it
can
never
be
stalled
in
the
inner/outer
end
positions
since
this
will
cause
damage
to
the
actuator.
7.
Make
a
rough
adjustment
on
the
actuator
stroke
so
that
it
is
set
to
approx.
80mm
with
its
inner
position
10mm
from
the
inner
end
stop
and
10mm
from
the
outer
end
stop.
The
below
example
shows
the
measurements
40mm
(inner
position)
and
120mm
(outer
position).
6