leD PAR 38 instRuction mAnuAl
DMX VALUES AND FUNCTIONS
Channel 1, 2, and 3 will not work when Channel 4 is being used. When units are daisy chained together
in DMX Mode, Channels 1, 2, and 3 must be “OFF” for units to sync together when using Channel 4.
When the value of Channel 6 is between 32 and 127, you must be using Channels 1, 2, or 3, or all
three combined.
When using Channel 6, Channel 5 will control the speed of the color changes.
CLEANING
Due to fog residue, smoke, and dust, clean the internal and external optical lenses
periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside case.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always dry all parts completely before plugging the unit back in. Cleaning frequency depends on
the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
Page 6
Channel Value
Function
1 0 - 255 RED
0% 100%
2 0 - 255 GREEN
0% 100%
3 0 - 255 BLUE
0% 100%
4 8 - 255 COLOR MACRO
5 0 - 15 NOTHING
16 - 255 STROBING
6 0 - 31 NOTHING
DIMMING CONTROL
32 - 63 DIM BRIGHT
64 - 95 BRIGHT DIM
96 - 127 DIM BRIGHT DIM
128 - 159 COLOR MIXING
160 - 191 3 COLOR CHANGE
192 - 223 7 COLOR CHANGE
224 - 255 SOUND ACTIVE