Heat recovery air handling unit

VUT 200 V EC

VUE 200 V EC

VUT 200 VB EC

VUE 200 VB EC

VUT 250 V EC

VUE 250 V EC

VUT 250 VB EC

VUE 250 VB EC

USER'S MANUAL

Содержание VUT V EC A11 Series

Страница 1: ...Heat recovery air handling unit VUT 200V EC VUE 200V EC VUT 200VB EC VUE 200VB EC VUT 250V EC VUE 250V EC VUT 250VB EC VUE 250VB EC USER S MANUAL ...

Страница 2: ...cts at any time in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means in any information search system or translated into any language in any form without the prior written permission of the Company Please read the user s manual carefully prior to installing and operating t...

Страница 3: ...r Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the ...

Страница 4: ...intended for organizing ventilation in swimming pools saunas greenhouses summer gardens and other spaces with high humidity Due to the ability to save heating energy by means of energy recovery the unit is an important element of energy efficient premises The unit is a component part and is not designed for stand alone operation It is rated for continuous operation Transported air must not contain...

Страница 5: ...ow counter flow counter flow counter flow Heat exchanger material polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy polystyrene enthalpy SEC class A A A A A A A A Overall and connecting dimensions mm VUT VUE 200V B EC Ø 18 564 290 326 771 858 97 97 85 115 85 115 279 279 Ø124 VUT VUE 250V B EC Ø 18 567 450 489 788 881 204 123 110 110 90 254 344 Ø160 5 www ventilation system com VUT VUE...

Страница 6: ...d is removed outside through the drain pipe The VUE 200 250 V B EC units are equipped with an enthalpy heat exchanger and do not require condensate drainage Accessories for the unit are available on a separate order Humidity sensor The unit with an installed humidity sensor maintains a set indoor humidity level As the extract air humidity rises above the set point the system automatically switches...

Страница 7: ... air temperature downstream of the heat exchanger is lower than 5 C and intake air temperature upstream of the heat exchanger is lower than 3 C for the units with preheating and when exhaust temperature downstream of the heat exchanger is lower than 3 C for the units without preheating To protect the heat exchanger from freezing in the cold season the unit has a Frost Protection mode based on the ...

Страница 8: ...ened Bypass duct is opened VUT VUE 200 V B EC VUT VUE 250 V B EC VUT VUE 200 V B EC VUT VUE 250 V B EC VUT VUE 200 V B EC VUT VUE 250 V B EC VUT VUE 200 V B EC VUT VUE 250 V B EC INTAKE AIR SUPPLY AIR EXTRACT AIR EXHAUST AIR INTAKE AIR SUPPLY AIR EXTRACT AIR EXHAUST AIR INTAKE AIR SUPPLY AIR EXTRACT AIR EXHAUST AIR INTAKE AIR SUPPLY AIR EXTRACT AIR EXHAUST AIR 8 VUT VUE 200 250 V B EC www ventilat...

Страница 9: ...nnector with a cable from the control unit The connector is mounted by the manufacturer HV2 humidity sensor mounting sequence Remove the screws that retain the panel on side of the extract spigot and remove it Place the humidity sensor in the mount Connect the humidity sensor connector to the connector with a cable from the control unit The connector is mounted by the manufacturer Extract air duct...

Страница 10: ...casing The delivery set includes a label indicating the filter type and the air flow direction Stick it on a removable plate only for the VUT VUE 250 V B EC units F7 F7 G4 G4 G4 G4 Before service side change After service side change Note service side change is shown by the example of the VUT VUE 250 V B EC unit 10 VUT VUE 200 250 V B EC www ventilation system com ...

Страница 11: ...ing fasteners consider the material of the mounting surface as well as the weigh of the unit refer to the Technical data section Fasteners for unit installation should be selected by a qualified technician Secure the wall bracket at the desired level Hang the unit on the bracket UNIT FLOOR MOUNTING Install the unit on the pre mounted floor supports minimum 150 mm height to ensure sufficient access...

Страница 12: ... UNIT ARE GIVEN ON THE MANUFACTURER S LABEL ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID THE WARRANTY The unit is rated for connection to 1 230 V 50 60 Hz power mains The unit must be connected to power mains using insulated electric conductors cables wires The actual wire cross section selection must be based on the maximum load current maximum conductor temperature dep...

Страница 13: ...75 mm2 20 m LF 230 SМ2 Extract air damper actuator 2x0 75 mm2 20 m LF 230 РК Contact from fire alarm panel 2x0 75 mm2 20 m no КН Contact from kitchen hood 2x0 5 mm2 20 m no Р1 Control panel 4x0 25 mm2 10 m ТЕ1 Outdoor temperature sensor inside the unit Is not included in the delivery set EXTERNAL WIRING DIAGRAM FOR THE VUT VUE 250 V B EC A14 UNIT External device NO CO2 sensor PK fire alarm panel r...

Страница 14: ... Х1 N N N L1 L1 no c KH Brown Yellow Green White Designation Name Model Wire CCU DX cooler NO 2x0 75 mm2 SМ1 Supply air damper actuator LF 230 2x0 75 mm2 SМ2 Extract air damper actuator LF 230 2x0 75 mm2 РК1 Contact from fire alarm panel NO 2x0 75 mm2 КН Contact from kitchen hood NO 2x0 75 mm2 Р1 External control panel The unit is not included in the delivery set ELECTRIC SHOCK HAZARD 14 VUT VUE 2...

Страница 15: ... AC SМ2 Extract air damper actuator NO 2 x 0 75 mm2 3 A 30VDC 250 AC РК1 Contact from fire alarm panel NC 2 x 0 75 mm2 CCU CCU control NO 2 x 0 75 mm2 3 A 30VDC 250 AC Р1 External control panel 4 x 0 25 mm2 Boost Contacts ON OFF Boost NO 2 x 0 75 mm2 CO2 Outdoor CO2 sensor 3 x 0 75 mm2 Is not included in the delivery set The supply voltage U of the SM1 and SM2 external dampers is selected dependin...

Страница 16: ...nce of the filters To maintain the high heat recovery efficiency regular cleaning is required Wet cleaning of the heat exchanger To clean the heat exchanger pull it out flush the heat exchanger with warm detergent solution After cleaning install the dry heat exchanger back to the unit Dry cleaning of the heat exchanger Remove the clogged heat exchanger out of the unit clean it with a vacuum cleane...

Страница 17: ...rwise troubleshoot the connection error The mode in which the fans are turned off is set Change the mode with the help of the control panel Low air flow Low set fan speed Set higher speed The filters and the fans are clogged the heat exchanger is clogged Clean or replace the filters clean the fans and the heat exchanger Ventilation system elements air ducts diffusers louver shutters grilles are cl...

Страница 18: ... to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prio...

Страница 19: ...failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casing exc...

Страница 20: ...20 VUT VUE 200 250 V B EC www ventilation system com ...

Страница 21: ...21 www ventilation system com VUT VUE 200 250 V B EC ...

Страница 22: ...22 VUT VUE 200 250 V B EC www ventilation system com ...

Страница 23: ...e Quality Inspector s Stamp The VUT VUE V______________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical a...

Страница 24: ...V106 5EN 04 ...