POSSIBLE MALFUNCTIONS AND TROUBLESHOOTING

STORAGE AND TRANSPORTATION REGULATIONS

•  Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range 

from +5 ˚С  up to +40 ˚С  and relative humidity up to 70 %.

•  Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing 

deformation.

•  Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
•  Follow the handling requirements applicable for the particular type of cargo.
•  The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and 

mechanical damage. The unit must be transported only in the working position.

•  Avoid sharp blows, scratches, or rough handling during loading and unloading.
•  Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at 

least 3-4 hours.

PROBLEM

POSSIBLE REASONS

TROUBLESHOOTING

When switching on the unit the 
fan does not start.

No power supply.

Check the electrical connections and the power switch status. 

Motor jamming. 

Turn off the fan. Troubleshoot the impeller jamming. Restart the 
fan.

Circuit breaker tripping during the 
fan start.

The automatic circuit breaker is 
triggered by an abnormally high current 
consumption due to a short circuit. 

Disconnect the fan from power mains and contact the Seller. 
Do not turn on the fan again! 

Low air flow.

Clogging of air ducts or other ventilation 
system elements. Impeller clogging.
Damaged air ducts. Air damper closure.

Clean the air ducts and other ventilation system elements as 
well as the impeller.  Check the air ducts for damage. Make sure 
the air dampers and louvre shutters are open. 

Содержание VKM 100

Страница 1: ...VKM 100 Q VKM 100 VKM 125 Q VKM 125 VKM 150 E VKM 150 VKMS 150 VKM 160 VKMS 160 VKM 200 VKMS 200 VKM 250 E VKM 250 VKM 315 VKMS 315 VKM 355 Q VKM 400 VKM 450 Centrifugal inline fans USER S MANUAL...

Страница 2: ...all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior...

Страница 3: ...e made through a disconnecting device which is integrated into the fixed wiring system in accordance with the wiring rules for design of electrical units and has a contact separation in all poles that...

Страница 4: ...als sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs THE UNIT MUST NOT...

Страница 5: ...Dimensions mm Weight kg D D1 B B1 L L1 L2 L3 VKM 100 Q 99 245 301 261 195 20 20 30 2 1 VKM 100 99 245 301 261 195 20 20 30 2 4 VKM 125 Q 123 255 310 270 205 20 25 30 2 9 VKM 125 123 255 310 270 205 2...

Страница 6: ...mperature controller are connected to power mains through a power cable with a plug VKM Un VKM P 1 2 3 4 5 6 7 8 9 10 11 12 9 Fig 1 6 outer fixing bracket 7 screws 8 bolt 9 knob for controlling fan im...

Страница 7: ...section selection must be based on its type maximum permissible heating insulation length and installation method in the air pipes or inside walls Connect the cables to the terminal block incorporate...

Страница 8: ...ol knob 9 The fan on off light indicator 11 lights up The controller switches the fan to the maximum speed maximum air flow as the temperature rises and crosses the thermostat setpoint The thermostat...

Страница 9: ...harp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm up at operating temperature for at lea...

Страница 10: ...eller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including...

Страница 11: ...TE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Страница 12: ...V05EN_A4_stkr 11...

Отзывы: