![Vents VCN 100 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/vents/vcn-100/vcn-100_user-manual_1002580004.webp)
4
VCN/VCN EC
www.ventilation-system.com
PURPOSE
The VCN/VCN EC centrifugal fans are designed for exhaust ventilation of living spaces, offices, shops, garages, kitchens, bathrooms and
other residential and public premises.
The unit is not intended for organizing ventilation in swimming pools, saunas, greenhouses, summer gardens, and other spaces with
high humidity.
The fans are designed for vertical mounting at ventilation shaft outlets and are rated for continuous operation.
The unit is rated as a class I electric appliance.
Ingress protection rating against access to hazardous parts and water ingress – IPX4.
The minimum operating temperature of the transported air is -25 ° С, for a short time - up to -30 ° С, the maximum permissible temperature
is up to +50 ° С.
Transported air must not contain dust and other solid impurities, sticky substances and fibrous materials.
The fan design is constantly being improved, thus some models may be slightly different from those described in this manual.
THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED
PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE
TRAINING. THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY
QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING.
THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED
ACCESS BY UNATTENDED CHILDREN.
THE UNIT MUST NOT BE OPERATED IN KITCHEN PREMISES.
DELIVERY SET
Name
Number
Fan
1 pc.
Dowel with a screw
4 pcs.
User's manual
1 pc.
Packing box
1 pc.
DESIGNATION KEY
VCN
XXX
EC
K
S
High-powered motor
Equipped with a backdraft damper
Motor type
_ – asynchronous
EC – electronically commutated
Outlet spigot diameter [mm]
Fan series
Содержание VCN 100