MOUNTING AND SET-UP 

 

WALL-MOUNTED CONTROL PANEL INSTALLATION

MAKE SURE THAT THE CONTROL PANEL IS NOT DAMAGED. DO NOT USE A 

DAMAGED CONTROL PANEL! DO NOT INSTALL THE CONTROL PANEL ON AN UNEVEN 

SURFACE! WHILE TIGHTENING THE SCREWS, DO NOT APPLY EXCESSIVE FORCE TO 

PREVENT THE CONTROL PANEL CASING DEFORMATION.

Installation of a LCD control panel 

1. 

Prepare a hole in the wall and 

route all the wires to the installation 

place. Insert the supplied mounting 

box for flush wall mounting. 

2.

 

Use a screwdriver to 

carefully undo the clips on 

the backside of the control 

panel and disconnect the 

front side from the back 

cover. While doing that do 

not disconnect the socket 

connectors in the casing. 

3. 

Connect the wires to the 

terminal blocks on the backside 

in compliance with external wiring 

diagram. Screw the backside of the 

control panel to the mounting box 

through the fastening holes. The 

screws are included in the delivery 

set. 

4. 

Install the control panel 

display and press it to fix.   

 

V127EN-01.indd   8

29.03.2016   9:56:06

Содержание TwinFresh Easy RL-50-7

Страница 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Easy V127EN 01 indd 1 29 03 2016 9 56 03...

Страница 2: ...cal specification applies to the installation and mounting of the single room energy regeneration reversible ventilator TwinFresh Easy hereinafter the unit as mentioned in the Safety Requirements and...

Страница 3: ...the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or e...

Страница 4: ...Internal square ventilation grille 1 item 2 items External grille 1 item 2 items Control panel 1 item 1 item Remote control 1 item 1 item Mounting fasteners 1 item 1 item Mounting box 1 item 1 item U...

Страница 5: ...0 18 50 29 Filters G3 MERV 7 F8 MERV 13 option Transported air temperature C F from 30 22 to 50 122 Noise level 1 m dB A Sones 24 0 6 31 1 0 34 1 2 24 0 6 31 1 0 34 1 2 Noise level 3 m dB A Sones 15 0...

Страница 6: ...r ow DESIGN AND OPERATING LOGIC The ventilator consists of decorative protecting internal grille a cartridge an air duct with a sound absorbing material and a protecting external ventilation grille Ca...

Страница 7: ...up to 97 heat energy In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to supply mode Cycle II Fresh intake air from outside flows through the ceramic regenerator and ab...

Страница 8: ...the wires to the installation place Insert the supplied mounting box for flush wall mounting 2 Use a screwdriver to carefully undo the clips on the backside of the control panel and disconnect the fro...

Страница 9: ...example a wall ceiling or a window as well as the minimum distance between the ventilators are shown below min 1 m min 39 3 8 min 1 m min 39 3 8 min 1 m min 39 3 8 min 500 mm min 19 11 16 180 mm 7 1...

Страница 10: ...ct No glue is required for fixation 1 Ventilator with outer hood option Mark the sound absorbing layer at the end of the air duct as 1 Cut the excessive part of the sound absorbing layer Insert the ad...

Страница 11: ...The circuit breaker trip current must exceed the consumption current of the ventilator For details please refer to table at page 5 For electric installations use insulated durable and heat resistant e...

Страница 12: ...re In case of power cut off the set parameters are saved in the non volatile memory of the control panel VENTILATOR OPERATION WITH THE BUTTONS ON THE LCD CONTROL PANEL Turning ventilator on off Enteri...

Страница 13: ...press the button sequentially Operation hour meter Package Turning OFF mode Speed setting 5 Speed setting in Engineering menu Operation hour meter The hour meter shows the actual hours run time To res...

Страница 14: ...ion Ventilation mode The ventilator operates in air extract or air supply mode Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat regenera...

Страница 15: ...UCT CLOSING Close Open Round internal grille To close the air duct rotate a small handle between the louvre shutters clockwise against stop To open the air duct rotate this handle counter clockwise V1...

Страница 16: ...rs as often as required but at least 3 times a year After expiry of the period set for the hour meter factory setting 90 days the filter replacement indicator appears on the control panel display Wash...

Страница 17: ...he ventilator off Contact the Seller for further information Low air flow Low set fan speed Set higher speed The filters the fan or the regenerator is soiled Clean or replace the filter Clean the fan...

Страница 18: ...f the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the un...

Страница 19: ...Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are acknowledged and accepted Custo...

Страница 20: ...V127EN 01 V127EN 01 indd 20 29 03 2016 9 56 11...

Отзывы: