background image

OPERATION MANUAL

PА 01 Е 

PА 02 Е

PА 03 Е

Air Supply Unit

Содержание PA 01 E

Страница 1: ...OPERATION MANUAL PА 01 Е PА 02 Е PА 03 Е Air Supply Unit ...

Страница 2: ...quirements Design and Operating Principle Installation and Setup Power Mains Connection Technical Maintenance Troubleshooting Storage and Transportation Rules Manufacturer s Warranty Acceptance Certificate Connection Certificate Warranty Card 3 3 3 3 4 5 6 6 8 9 10 10 11 12 12 12 CONTENTS ...

Страница 3: ...sent Operation Manual consisting of technical details operating instructions and technical specification for the installation of the PA E air supply unit of VENTS series hereinafter Unit The unit is not intended for operation by children or any persons with reduced physical mental or sensory capacities as well persons lacking the required training The unit must be handled only by properly qualifie...

Страница 4: ... designations outside and connecting connections as well and its appearance are given on Fig 1 and in Table 1 whereas the Table 2 contains the technical parameters The units undergo continuous improvements therefore some models may slightly differ from the ones described herein Fig 1 Outside and Connection Dimensions of Unit Type Dimensions mm B B1 B2 B3 H H1 H2 L L1 PA 01 Е 400 420 624 582 200 22...

Страница 5: ... REQUIREMENTS While operating and mounting the unit consider the requirements of the present operation manual as well as general requirements of all applicable local and national building and electrical codes and standards The unit must be properly earthed Before connecting the unit to power mains make sure that the unit is free of any visible damages or any other foreign objects inside the casing...

Страница 6: ... 3 Detachable cover Item 4 INSTALLATION AND SETUP The unit installation must ensure sufficient access for maintenance servicing or replacement operations The arrow on cover must match the air flow direction in the system The unit is suspended on a rod threaded into an expansion anchor or alternatively securely fixed in a horizontal position Fig 3 The unit is integrated into a ventilation system by...

Страница 7: ...ll the suspension bolts Insufficient strength of the structure used for the installation may resonate in response to the block vibrations resulting in noise Always arrange for a maintenance zone and an access hole in the ceiling for inspection of the filters heat exchanger and fans Provide a separate access hole for each unit see more details on the outline drawing Fig 1 Prior to installation make...

Страница 8: ...0Hz must be equipped with an automatic cutout switch with a magnetic breaker built into the stationary wiring to disconnect all the mains phases The position of QF external switch must ensure free access for quick power off The electric heater power contacts L1 L2 and L3 is supplied autonomously to terminal block X2 on the heater side wall according to the electrical wiring diagram Fig 4 The same ...

Страница 9: ...ease air resistance in the system and reduce supply air volume The filters require cleaning once in 3 4 months Vacuum cleaning is allowed Worn out filters should be replaced with the new filters once or twice per year Contact your local manufacturer representative for new filters To replace the filter 1 Remove the cover 2 Replace the filter 3 Reinstall the cover 2 Fan inspection once per year Even...

Страница 10: ...e screw tightening Possible faults and fault handling STORAGE ANDTRANSPORTATION RULES Store the unit in the manufacturer s original packing box in a closed ventilated premise with temperature range from 10 C to 40 C and relative humidity less than 80 at 20 C Vapors or particles which can cause corrosion or damage the insulation or connection tightness are not allowed in the storage environment Use...

Страница 11: ...case of no confirmation of the sales date the warranty period is calculated from the manufacturing date In case of failures in the unit operation during the warranty period the manufacturer will accept reclamations and complaints from the owner of the device only after receiving technically sound act with detailed description of the failure Unit damage as a result of unauthorized tampering with th...

Страница 12: ..._______________________ ___________________________________________________________________________________ Date of sale _____________________________ ACCEPTANCE CERTIFICATE ELECTRICAL CONNECTION CERTIFICATE WARRANTY CARD Company Name Date Signature This is to certify that the air handling unit PA E has been connected to power mains pursuant to the requirements stated in the present user s manual ...