Vents OV Скачать руководство пользователя страница 6

6

OV / OVK / VKf / OVP / OV1 / OVK1 / OV1 r / VKOM(z) / VKOM1(z)

www.ventilation-system.com

OV /

OVK / 

VKF 

4D 500

OV /

OVK / 

VKF 

6D 500

OV /

OVK / 

VKF 

 4D 550

OV /

OVK / 

VKF 

 6D 550

OV /

OVK / 

VKF 

 4D 630

OV /

OVK / 

VKF 

 6D 630

OV /

OVK / 

VKF

 6D 710

OV /

OVK / 

VKF 

 8D 710

OV /

OVK / 

VKF 

 6D 800

OV /

OVK / 

VKF 

 8D 800

Voltage [V]

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

3 ~ 400

frequency [Hz]

50

60

50

60

50

60

50

60

50

60

50

60

50

50

50

50

Power [W]

450

370

230

281

750

600

337

447

800

910

550

716

1150

700

1850

700

current [a]

0.9

0.7

0.58

0.59

1.5

1.1

0.9

0.95

1.6

1.68

1.45

1.56

2.0

1.5

3.7

1.7

Maximum air flow 
[m³/h (l/s)] 

6570  

(1825)

6230  

(1731)

4900  

(1361)

5430  

(1508)

9700  

(2695)

7380  

(2050)

6400  

(1778)

6520  

(1811)

12200  
(3389)

12400  
(3445)

1950  
(542)

11120  
(3089)

15440  
(4289)

12000  
(3334)

25000  
(6945)

15550  
(4320)

rPM [min

-1

]

1300

1605

920

1015

1350

1605

910

1020

1320

1585

900

1060

830

710

915

710

noise level at 3 m [dBa]

60

60

57

57

64

64

61

61

69

69

59

59

63

61

67

66

transported air 
temperature [°c]

-30..+60 -30..+50 -30..+60 -30..+50 -30..+60 -30..+50 -30..+60 -30..+50 -30..+60 -30..+50 -30..+60 -30..+50 -30...+60

-30...+60

-30...+60

-30...+60

iP rating

iPx4

iPx4

iPx4

iPx4

iPx4

iPx4

iPx4 

iPx4 

iPx4

iPx4 

Motor iP rating

iP24

iP24

iP24

iP24

iP24

iP24

iP44

iP44

iP44

iP44

OV1 / 

OVK1 / 

VKOM(z) /

VKOM1(z) 

150 

OV1 / 

OVK1 / 

VKOM(z) /

VKOM1(z)  

200 

OV1 / 

OVK1 / 

VKOM(z) /

VKOM1(z)  

250

OV1 / 

OVK1 / 

VKOM(z) /

VKOM1(z)  

315 

Voltage [V]

1~ 220-240

1~ 220-240

1~ 220-240

1~ 220-240

frequency [Hz]

50

60

50

60

50

60

50

60

Power [W]

36

26

43

33

68

76

110

104

current [a]

0,26

0,26

0,28

0,21

0,48

0,51

0,75

0,7

Maximum air flow [m³/h (l/s)] 

200

205

405

470

1070

1050

1700

1650

rPM [min

-1

]

1300

1590

1300

1615

1300

1450

1300

1365

noise level at 3 m [dBa]

33

34

32

31

48

48

54

54

transported air temperature [°c]

-30...+40

-30...+40

-30...+40

-30...+40

iP rating

iP24

iPx4 (VKOM(z), VKOM1(z))

iP24

iPx4 (VKOM(z), VKOM1(z))

iP24

iPx4 (VKOM(z), VKOM1(z))

iP24

iPx4 (VKOM(z), VKOM1(z))

OVP 2Е 200

OVP 2Е 250

OVP 4Е 250

OVP 2Е 300

OVP 4Е 300

OVP 4Е 350

Voltage [V/50 Hz]

1-230

1-230

1-230

1-230

1-230

1-230

Power [W]

55

80

50

145

75

140

current [a]

0.26

0.4

0.22

0.66

0.35

0.65

Maximum air flow [m³/h (l/s)] 

860

1050

800

2230

1340

2500

rPM [min

-1

]

2300

2400

1380

2300

1350

1380

noise level at 3 m [dBa]

50

60

55

60

58

62

transported air temperature [°c]

-30...+60

-30...+60

-30...+60

-30...+60

-30...+60

-30...+60

iP rating

iPХ4

iPХ4

iPХ4

iP Х4

iPХ4

iPХ4

Содержание OV

Страница 1: ...USER S MANUAL Electric axial fans OV OVK VKF OVP OV1 OVK1 OV1 R VKOM z VKOM1 z...

Страница 2: ...ating staff The manual contains information about purpose technical details operating principle design and installation of the OV OVK VKF OVP OV1 OVK1 OV1 R VKOM z VKOM1 z unit and all its modificatio...

Страница 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Страница 4: ...ULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIF...

Страница 5: ...20 268 550 654 330 375 750 979 540 610 Current A 1 2 1 46 0 78 0 8 1 95 2 05 1 1 1 22 2 55 2 88 1 6 1 63 3 5 4 26 2 4 2 74 Maximum air flow m h l s 4680 1300 4790 1331 3200 889 3250 903 7060 1961 7130...

Страница 6: ...30 50 30 60 30 60 30 60 30 60 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 Motor IP rating IP24 IP24 IP24 IP24 IP24 IP24 IP44 IP44 IP44 IP44 OV1 OVK1 VKOM z VKOM1 z 150 OV1 OVK1 VKOM z...

Страница 7: ...460 9 165 7 5 OVK 4E 400 OVK 4D 400 417 504 528 9 220 8 5 OVK 4E 450 OVK 4D 450 OVK 6E 450 OVK 6D 450 465 578 607 11 230 10 0 OVK 4E 500 OVK 4D 500 OVK 6E 500 OVK 6D 500 520 590 655 11 250 14 0 OVK 4E...

Страница 8: ...0 6 1 OV1 Model Dimensions mm Weight kg D D1 D2 d L OVK1 150 162 190 220 7 120 2 5 OVK1 200 208 270 300 7 120 2 5 OVK1 250 262 330 360 7 140 3 0 OVK1 315 312 390 420 9 170 5 1 OVK1 Model Dimensions mm...

Страница 9: ...mm air ducts The reducers are not included in the delivery set and must be ordered separately Model Dimensions mm Weight kg D D1 H H1 RM z 148 158 148 158 140 55 0 3 RM z 198 204 198 204 140 55 0 4 R...

Страница 10: ...ve ground circuit OV OVK 3 4 1 2 5 3 4 1 2 The OV1 and OVK1 fans consist of a casing 1 made of polymer coated stainless steel with a square OV1 or round OVK1 flange to which the grille 2 is fastened w...

Страница 11: ...and check that it rotates freely without catching against the inlet flange and the casing Prior to powering up the fan make sure that the mains parameters comply with the technical specifications on...

Страница 12: ...12 OV OVK VKF OVP OV1 OVK1 OV1 R VKOM z VKOM1 z www ventilation system com OV fan installation OVK fan installation...

Страница 13: ...13 www ventilation system com OV1 and OVK1 fan installation...

Страница 14: ...the direction of the arrow shown on the casing matches the direction of air flow in the system The power is supplied via the remote position terminal box OVP andVKOM1 z fan installation The fans are i...

Страница 15: ...secured with clamps The power is supplied via terminal box on the fan casing The VKOM z delivery set includes mounting brackets for attaching the unit to the mounting surface Depending on a delivery...

Страница 16: ...table The recommended trip current of the circuit breaker is the next current in the standard trip current row following the maximum current of the connected unit The automatic circuit breaker is not...

Страница 17: ...17 www ventilation system com OV and OVK fan connection OV1 fan connection...

Страница 18: ...18 OV OVK VKF OVP OV1 OVK1 OV1 R VKOM z VKOM1 z www ventilation system com VKF VKOM z VKOM1 z fan connection OVP fan connection...

Страница 19: ...while avoiding water penetration onto the electric motor Wipe the cleaned surfaces dry To carry out technical maintenance of the VKF VKOM z VKOM1 z OVP fans remove the fans from the duct by undoing t...

Страница 20: ...20 OV OVK VKF OVP OV1 OVK1 OV1 R VKOM z VKOM1 z www ventilation system com OV1 and OVK1 technical maintenance OVP VKOM z VKOM1 z technical maintenance...

Страница 21: ...re open If the malfunction is too complex to be eliminated on the spot contact the fan Seller STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dr...

Страница 22: ...manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the us...

Страница 23: ...OV OVK VKF OVP OV1 OVK1 OV1 R VKOM VKOM1 _______ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation T...

Страница 24: ...V03EN 11...

Отзывы: