background image

www.ventilation-system.com

21

MANUFACTURER’S WARRANTY

The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user’s observance of the 

transportation, storage, mounting and operation regulations.

Should any malfunctions occur in the course of the unit operation through the Manufacturer’s fault during the guaranteed period of operation the user 

is entitled to elimination of faults by the manufacturer by means of warranty repair at the factory free of charge.

The warranty repair shall include work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed 

period of operation. The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include:

• 

routine technical maintenance

• 

unit installation/dismantling

• 

unit setup

To benefit from warranty repair the user must provide the unit, the user’s manual with the purchase date stamp and the payment document certifying 

the purchase.

The unit model must comply with the one stated in the user’s manual.

 

Contact the Seller for warranty service.

The manufacturer’s warranty does not apply to the following cases:

• 

User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component 
parts previously dismounted by the user.

• 

Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user’s manual.

• 

User’s failure to ensure timely technical maintenance of the unit.

• 

External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.

• 

Redesign or engineering changes to the unit.

• 

Replacement and use of any assemblies, parts and components not approved by the manufacturer.

• 

Unit misuse.

• 

User’s violation of the unit installation regulations.

• 

User’s violation of the unit control regulations.

• 

Unit connection to the power mains with a voltage different from the one stated in the user’s manual.

• 

Unit breakdown due to voltage surges in the power mains.

• 

Discretionary repair of the unit by the user.

• 

Unit repair by any persons without the manufacturer’s authorization.

• 

Expiration of the unit warranty period.

• 

User’s violation of the unit transportation regulations.

• 

User’s violation of the unit storage regulations.

• 

Wrongful actions against the unit committed by third parties.

• 

Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).

• 

Missing seals if provided by the user’s manual.

• 

Failure to submit the user’s manual with the unit purchase date stamp.

• 

Missing payment document certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE-FREE 

OPERATION OF THE UNIT.
USERS’ WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT, 

THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE PURCHASE DATE STAMP.

Содержание NK 100-0,6-1

Страница 1: ...USER S MANUAL VENTS NK duct heater...

Страница 2: ...prior to installing and operating the unit Fulfil the user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and sta...

Страница 3: ...ect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour o...

Страница 4: ...orted air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the format...

Страница 5: ...C A NK 100 0 6 1 99 306 226 207 40 94 NK 100 0 8 1 99 306 226 207 40 94 NK 100 1 2 1 99 306 226 207 40 94 NK 100 1 6 1 99 306 226 207 40 94 NK 100 1 8 1 99 376 296 207 40 94 NK 125 0 6 1 124 306 226 2...

Страница 6: ...14 302 40 150 NK 200 3 4 1 199 294 214 302 40 150 NK 200 3 6 3 199 376 296 302 40 150 NK 200 5 1 3 199 376 296 302 40 150 NK 200 6 0 3 199 376 296 302 40 150 NK 250 1 2 1 249 306 226 356 40 150 NK 250...

Страница 7: ...1x1 2 5 2 150 2 1 NK 160 1 7 1 1 7 1 230 1x1 7 7 4 160 2 1 NK 160 2 0 1 2 0 1 230 1x2 0 8 7 170 2 1 NK 160 2 4 1 2 4 1 230 2x1 2 10 4 180 2 5 NK 160 3 4 1 3 4 1 230 2x1 7 14 8 250 2 5 NK 160 3 6 3 3...

Страница 8: ...500x250 6 0 3 640 290 520 270 500 250 200 NK 500x250 7 5 3 640 290 520 270 500 250 200 NK 500x250 9 0 3 640 290 520 270 500 250 200 NK 500x250 10 5 3 640 290 520 270 500 250 200 NK 500x250 12 0 3 640...

Страница 9: ...0 600 350 200 NK 600x350 15 0 3 740 390 620 370 600 350 200 NK 600x350 18 0 3 740 390 620 370 600 350 200 NK 600x350 21 0 3 740 390 620 370 600 350 200 NK 600x350 24 0 3 740 390 620 370 600 350 200 NK...

Страница 10: ...2 0 3 400 3x4 0 17 4 880 8 2 NK 500x300 15 0 3 15 0 3 400 3x5 0 21 7 1100 8 2 NK 500x300 18 0 3 18 0 3 400 3x6 0 26 0 1320 8 2 NK 500x300 21 0 3 21 0 3 400 3x7 0 30 0 1540 8 2 NK 600x300 9 0 3 9 0 3 4...

Страница 11: ...supply and control circuits of the heater screw ground terminal hermal switches automatic and manual The heaters are equipped with two overheating sensors thermal switches with automatic reset and tem...

Страница 12: ...tic circuit breaker with a minimum gap of 3 mm between the open contacts on all poles The circuit breaker must be integrated into the stationary wiring in accordance with the applicable electrical wir...

Страница 13: ...the switch to the original position CONNECTING ROUND AIR DUCTS TO THE HEATER The heater is designed for internal installation into air ducts in the horizontal or vertical position In a horizontal posi...

Страница 14: ...nal lead in 230 V 50 Hz or 400 V 50 Hz must be equipped with an automatic circuit breaker built into the stationary wiring to interrupt all the network phases in case of a short circuit or an overload...

Страница 15: ...ITH TWO ELECTRICAL HEATING ELEMENTS AND SINGLE PHASE POWER SUPPLY 1 X1 S1 S2 T RESET E1 E2 X2 PE N L T 2 3 4 5 6 WIRING DIAGRAM OF THE HEATER WITH THREE ELECTRICAL HEATING ELEMENTS AND SINGLE PHASE PO...

Страница 16: ...THE HEATER WITH THREE ELECTRICAL HEATING ELEMENTS AND THREE PHASE POWER SUPPLY X1 S1 T0 S2 T0 RESET E1 E1 E1 X2 PE L3 L2 L1 2 1 3 4 5 6 7 1 X1 S1 T0 T0 S2 RESET E1 E2 E3 X2 PE L3 L2 L1 2 3 4 5 6 7 8...

Страница 17: ...S LEADED OUTSIDE S1 S2 T T RESET X2 E1 E2 E3 E4 E5 E6 E7 E8 E9 TK50 TK50 TK90 TK90 A1 B1 C1 A2 B2 C2 A3 B3 C3 PE WIRING DIAGRAM OF THE HEATER WITH SIX ELECTRICAL HEATING ELEMENTS THREE PHASE POWER SUP...

Страница 18: ...L Q S KT M KM N PE X2 RESET X1 S1 T T S2 1 2 3 4 5 6 WIRING DIAGRAM OF THE RECTANGULAR HEATER WITH THREE ELECTRICAL HEATING ELEMENTS THREE PHASE POWER SUPPLY STAR CONNECTION AND TIME DELAY RELAY L1 L...

Страница 19: ...lows As the ON OFF switch S turns ON the KM magnetic starter coil is charged through the closed contacts of the thermal switches Consequently electric power is supplied to the heating elements through...

Страница 20: ...r s original packing box in a dry ventilated premise at ambient temperatures from 10 C up to 40 C and at relative humidity max 80 The unit can be transported in the original packing by any mode of tra...

Страница 21: ...ismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of th...

Страница 22: ...nspector s Stamp SELLER INFORMATION Seller Address Phone Number E mail Purchase Date This is to certify acceptance of the complete unit delivery with the user s manual The warranty terms are acknowled...

Страница 23: ...www ventilation system com 23...

Страница 24: ...V09EN 08...

Отзывы: