Vents Bucket Fan 1055 Скачать руководство пользователя страница 8

8

Bucket Fan

Bucket Fan

BEFORE PERFORMING ANY MAINTENANCE ALWAYS ENSURE THAT THERE IS NO POWER TO THE FAN, 
YOU MUST DISCONNECT THE ELECTRICITY AT THE MAIN POWER SOURCE!

Annually:

1) Check to make sure the bolts are tight.
2) Check impeller for dirt or other matter. Clean if necessary.

• 

To clean, remove the four screws that secure the grille to the metal case.

• 

 Remove the grille from the case and clean the blades with warm, soapy water. Avoid splashing 
water on the motor.

• 

Wipe surfaces dry.

• 

Also clean the inside of the metal case while you are at it.

• 

Re-attach the grille to the case. 

• Electrical wiring should only be done by a qualifi ed electrician.
• Warranty will not cover equipment damage or failure that is caused by improper installation.
• If the fan did not come pre-wired or if a new wire is to be used, wire the fan as shown in the Figure 
6 below. 
• Use 18 AWG or greater wire. 

WIRING THE FAN

Fig. 6 

Bucket Fan 420

Bucket Fan Whisper 420

1.0 A

Bucket Fan 1055

Bucket Fan Whisper 1055

1.0 A

Bucket Fan 1460

Bucket Fan Whisper 1460

2.0 A

C1

X1

BLACK (LINE)

GREEN (PROTECTIVE EARTH)

WHITE (NEUTRAL)

Motor run capacitor

Motor terminal box

~

120 VAC 60 Hz

MAINTENANCE

Содержание Bucket Fan 1055

Страница 1: ...BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 Bucket Fan Whisper 420 Bucket Fan Whisper 1055 Bucket Fan Whisper 1460...

Страница 2: ...DUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION KEY EXAMPLE 3 SIZE RANGES 3 SAFETY REQUIREMENTS 4 MOUNTING AND INSTALLATION GUIDELINES 5 BUCKET FAN PARTS 7 MAINTENANCE 8 WIRING THE FAN 8 TROU...

Страница 3: ...rom the registers at the ceiling to occupant level DESIGNATION KEY EXAMPLE Bucket Fan 420 air destratification fan producing 420 CFM Bucket Fan Whisper 420 air destratification fan with isolated casin...

Страница 4: ...s inside the unit that can damage the motor and or impeller blades Misuse of the Bucket Fan and or any unauthorized design alterations or modifications voids the war ranty VENTS US assumes no liabilit...

Страница 5: ...ate the impeller by hand to ensure it turns smoothly Mounting The Bucket Fan comes with a set of Hanging Safety Cables with Gripples The set consists of two Gripples and two cables with a toggle on on...

Страница 6: ...ggle into the top hole on the handle Attaching the Safety Cable 1 Insert the cable into one of the openings in the Gripple 2 Place the cable over the I beam truss or other attaching structure at a 400...

Страница 7: ...he destratificator is equipped with a single phase asynchronous motor with an external rotor and an axial impeller The motor is equipped with built in thermal protection enabling its automatic restart...

Страница 8: ...aces dry Also clean the inside of the metal case while you are at it Re attach the grille to the case Electrical wiring should only be done by a qualified electrician Warranty will not cover equipment...

Страница 9: ...greater wire It is important that the controller be properly grounded for effective fan operation and personnel safety Always install the controller in sight of the fan it controls CAUTION Incorrectl...

Страница 10: ...sed in diverse applications A minimum speed adjustment is provided to allow independent control of the minimum speed setting Minimum speed adjustment ensures motor runs with sufficient torque to preve...

Страница 11: ...ive environment Avoid storing the fan in an area where it may be hit by a forklift where it will have to be moved a number of times etc Black Full Voltage Motor Red Red L2 L1 Black Variable Voltage 24...

Страница 12: ...improper maintenance or repair other than by VENTS US faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products is not covered The dur...

Отзывы: