This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the Airvents CFV unit 
and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Unit design and operating logic .......................................................................................................................................... 7
Installation and set-up................................................................................................................................................................ 9
Connection to power mains .................................................................................................................................................. 12
Technical maintenance .............................................................................................................................................................. 12
Storage and transportation regulations .......................................................................................................................... 14
Manufacturer’s warranty ........................................................................................................................................................... 15
Certificate of acceptance .......................................................................................................................................................... 19
Seller information .......................................................................................................................................................................... 19
Installation certificate .................................................................................................................................................................. 19
Warranty card ................................................................................................................................................................................... 19

SAFETY REQUIREMENTS

THE UNIT MUST BE GROUNDED!
DO NOT BEND THE POWER CABLE.
AVOID DAMAGING THE POWER CABLE.
DO NOT PUT ANY FOREIGN OBJECTS ON THE POWER CABLE.
DO NOT USE DAMAGED EQUIPMENT OR CABLES WHEN CONNECTING THE UNIT 

TO POWER MAINS.
DO NOT TOUCH THE UNIT CONTROLS WITH WET HANDS.
DO NOT CARRY OUT THE INSTALLATION AND MAINTENANCE OPERATIONS 

WITH WET HANDS.
DO NOT ALLOW CHILDREN TO OPERATE THE UNIT.
DO NOT STORE ANY EXPLOSIVE OR HIGHLY FLAMMABLE SUBSTANCES IN 

CLOSE PROXIMITY TO THE UNIT.
DO NOT OPEN THE UNIT DURING OPERATION.
DO NOT BLOCK THE AIR DUCT WHEN THE UNIT IS SWITCHED ON.
DO NOT SIT ON THE UNIT AND AVOID PLACING FOREIGN OBJECTS ON IT.
UNPACK THE UNIT WITH CARE.
WHILE INSTALLING THE UNIT, FOLLOW THE SAFETY REGULATIONS SPECIFIC TO 

THE USE OF ELECTRIC TOOLS.
DO NOT LAY THE POWER CABLE OF THE UNIT IN CLOSE PROXIMITY TO HEATING 

EQUIPMENT.

2

Airvents CFV

www.vents-us.com

Содержание Airvents CFV

Страница 1: ...Airvents CFV Air handling unit USER S MANUAL...

Страница 2: ...rer s warranty 15 Certificate of acceptance 19 Seller information 19 Installation certificate 19 Warranty card 19 SAFETY REQUIREMENTS THE UNIT MUST BE GROUNDED DO NOT BEND THE POWER CABLE AVOID DAMAGI...

Страница 3: ...ITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN READ THE US...

Страница 4: ...H THE PURCHASE DATE STAMP TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING USE THIS UNIT ONLY IN THE MANNER INTENDED BY THE MANUFACTURER IF YOU HAVE QUESTIONS CONTA...

Страница 5: ...substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs PURPOSE CAUTION FOR GENERAL...

Страница 6: ...01 AV02 AV03 AV07 AV12 CF counterflow R rotary P ceiling H double deck V vertical T rooftop 1000 1200 1500 2500 3500 5000 6000 9000 HE electric HW water _ no heater E enthalpy heat exchanger _ sensibl...

Страница 7: ...not included in the delivery set The frost protection for the water drainage and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with air cooler The h...

Страница 8: ...ater 3 electric heater only for the units with electric heater 4 supply fan 5 supply filter 6 extract fan 7 heat exchanger 8 extract fan 9 air flow control damper with electric actuator 10 bypass damp...

Страница 9: ...of the air duct positioning For this purpose the side walls are plugged To change positioning of the air ducts use the plugs from the side walls for the front panel Supply air Exhaust air Intake air...

Страница 10: ...ir Connection of the air ducts is shown with the stickers of the respective colours yellow for the extract air duct green for the intake air duct red for the supply air duct and brown for the exhaust...

Страница 11: ...nd are stated in the table H h Total Fan Pressure Size H Size h Pa inWG mm in mm in 600 2 4 100 3 15 16 50 1 15 16 600 1000 2 4 4 140 5 1 2 70 2 3 4 1000 1400 4 5 6 190 7 1 2 95 3 3 4 1400 1800 5 6 7...

Страница 12: ...for the models with water heater While connecting the water heater keep the straight air duct section length not less than 15 3 4 mm from the unit Otherwise the maintenance panel cannot be opened 15 3...

Страница 13: ...not a malfunction Clean the unit to troubleshoot unpleasant odours Open the service doors to access the filters Remove the filter elements WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY T...

Страница 14: ...To access the heat exchanger remove the holder 13 see page 7 Loosen the screws 1 on the retaining clamps 2 using a hexagon wrench 1 1 2 Pull the heat exchanger out 14 Airvents CFV www vents us com...

Страница 15: ...operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transpo...

Страница 16: ...gligence accident improper maintenance or repair other than by Vents US faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products is no...

Страница 17: ...___________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installa...

Страница 18: ...18 Airvents CFV www vents us com...

Страница 19: ...19 www vents us com...

Страница 20: ...VUSA192 5EN 02...

Отзывы: