CONNECTION OF SEVERAL VENTILATORS
One KVS-T power and control unit is able to control many TwinFresh Solar ventilators.
In case of connecting several TwinFresh Solar Pro ventilators each unit must be connected to its own solar panel or to its own battery unit.
The connecting cables K1, K2, Kn (3х0,25/3xAWG 24) are not included in the delivery set.
To provide balanced ventilation set one half of the ventilators to the air supply mode (In) and the other half of the ventilators to the air
extract mode (Out) by means of the JMP1 jumper.
Connect the ventilators in compliance with the terminal numbers as stated below.