background image

 

 

45704A 

Printed in Canada 

27-06-2019 

INSTALLATION AND OPERATION MANUAL 

HE250 

(VB00002 model)

 

 

US ENVIRONMENTAL PROTECTION AGENCY 

PHASE II CERTIFIED WOOD FIREPLACE 

 

 

Listed to standards ULC-S610 and UL 127 

 

www.occanada.com 

Manufactured by: 

Stove Builder International Inc. 

250 rue Copenhague, Saint-Augustin-de-Desmaures (Quebec), Canada,  G3A 2H3   

After-sale service: 418-908-8002     E-mail: [email protected] 

 

READ AND KEEP THIS MANUAL FOR REFERENCE 

 

 

This manual is available for free download on the manufacturer’s web site. It is a copyrighted document.  

Re-sale is strictly prohibited. The manufacturer may update this  manual from time to time and cannot be 

responsible for problems, injuries, or damages arising out of the use of information contained in any manual 

obtained from unauthorized sources.

 

Содержание HE250

Страница 1: ...ustin de Desmaures Quebec Canada G3A 2H3 After sale service 418 908 8002 E mail tech sbi international com READ AND KEEP THIS MANUAL FOR REFERENCE This manual is available for free download on the manufacturer s web site It is a copyrighted document Re sale is strictly prohibited The manufacturer may update this manual from time to time and cannot be responsible for problems injuries or damages ar...

Страница 2: ...als near it may overheat To reduce the risk of fire follow the installation instructions in this manual exactly Contact local building or fire officials about restrictions and installation inspection requirements in your area Please read this entire manual before you install and use your new fireplace You may need to get a building permit for the installation of this fireplace and the chimney that...

Страница 3: ...als That Should Not be Burned 13 3 2 How to Prepare or Buy Good Firewood 13 3 2 1 What is Good Firewood 13 3 2 2 Tree Species 13 3 2 3 Log Length 14 3 2 4 Piece Size 14 3 2 5 How to Dry Firewood 15 3 2 6 Judging Firewood Moisture Content 16 3 3 Manufactured Logs 16 4 Operating Your Fireplace 17 4 1 The use of a firescreen 17 4 2 Your First Fires 17 4 3 Lighting Fires 17 4 3 1 Conventional Fire Sta...

Страница 4: ...Regulations Covering Fireplace Installation 31 6 3 Fireplace Installation 32 6 3 1 Locating the HE250 32 6 3 2 Minimum Hearth Extension Requirements 39 6 3 3 Framing Facing Mantel and Combustible Shelf 40 7 Clearances to Combustible Material 46 7 1 Locating the Certification Label 46 8 The Venting System 47 8 1 General 47 8 2 Suitable Chimney 47 8 3 Minimum Chimney Height 47 8 4 The Relationship B...

Страница 5: ...en AC01560 81 Appendix 6 Installation of Secondary Air Tubes and Baffle 82 Appendix 7 Refractory slabs Replacement 86 Appendix 8 Exploded Diagram and Parts List 88 VENTIS LIMITED LIFETIME WARRANTY 91 REGISTER YOUR WARRANTY ONLINE To receive full warranty coverage you will need to show evidence of the date you purchased your unit Keep your sales invoice We also recommend that you register your warr...

Страница 6: ...RING LIGHTING PROCEDURES OR RELOADING ALWAYS CLOSE THE DOOR OR PUT BACK THE FIRESCREEN AFTER IGNITION DO NOT LEAVE THE FIREPLACE UNATTENDED WHEN THE DOOR IS OPENED WITH OR WITHOUT FIRESCREEN DO NOT INSTALL THE FIREPLACE OUTDOORS THE FIREPLACE AND CHIMNEY MUST BE IN AN ENCLOSURE UP TO THE ATTIC NEVER USE GASOLINE LANTERN FUEL NAPHTHA FUEL OIL MOTOR OIL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQ...

Страница 7: ...EPLACE NEEDS AIR FOR ITS GOOD OPERATION DO NOT BLOCK THE HOT AIR VENTS TO THE FIREPLACE AS THIS WILL CAUSE THE FIREPLACE TOOVERHEAT WARNING DO NOT USE MATERIALS OTHER THAN THOSE LISTED IN THE REPLACEMENT PARTS SECTION DURING INSTALLATION AS THEY MAY BE SAFETY HAZARDS AND A FIRE COULD RESULT WARNING THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED OR VENTED GAS LOG SET TO REDUCE RISK OF FIRE OR ...

Страница 8: ... loss factors climate fuel type and other variables The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure 1 Values are as measured per test method except for the recommended heating area firebox volume maximum burn time and maximum heat output 2 The maximum heat...

Страница 9: ...610 East west through the door you see the longitudinal sides of the logs north south through the door you see the tips of the logs Mobile home Canada or manufactured home USA The US department of Housing and Urban Development describes manufactured homes better known as mobile homes as followed buildings built on fixed wheels and those transported on temporary wheels axles and set on a permanent ...

Страница 10: ...10 HE250 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3 ...

Страница 11: ...y heating a particular space within a home such as a basement family room or an addition that lacks another heat source Houses of moderate size and relatively new construction can be heated with a properly sized and located wood fireplace Whole house zone heating works best when the fireplace is located in the part of the house where the family spends most of its time This is normally the main liv...

Страница 12: ...and judging its moisture 2 5 The Olympia Chimney Commitment to You and the Environment The Olympia Chimney team is committed to protecting the environment so we do everything we can to use only materials in our products that will have no lasting negative impact on the environment 2 5 1 What is Your New Fireplace Made Of The body of your fireplace which is most of its weight is carbon steel Should ...

Страница 13: ...wood Hardwoods are denser than softwoods People who live in the coldest regions of North America usually have only spruce birch and poplar other low density species to burn and yet they can heat their homes successfully Homeowners with access to both hardwood and softwood fuel sometimes use both types for different purposes For example softer woods make good fuel for relatively mild weather in spr...

Страница 14: ...s more quickly when it is split Large unsplit rounds can take years to dry enough to burn Even when dried unsplit logs are difficult to ignite because they don t have the sharp edges where the flames first catch Logs as small as 3 75 mm should be split to encourage drying Wood should be split to a range of sizes from about 3 to 6 75 mm to 150 mm in cross section Having a range of sizes makes start...

Страница 15: ... in dry weather than in damp maritime climates drying happens faster in warm summer weather than in winter weather small pieces dry more quickly than large pieces split pieces dry more quickly than unsplit rounds softwoods take less time to dry than hardwoods softwoods like pine spruce and poplar aspen can be dry enough to burn after being stacked in the open for only the summer months hardwoods l...

Страница 16: ...an wet wood split a piece and if the fresh face feels warm and dry it is dry enough to burn if it feels damp it is too wet burn a piece wet wood hisses and sizzles in the fire and dry wood does not You could buy a wood moisture meter to test your firewood 3 3 Manufactured Logs Do not burn manufactured logs made of wax impregnated sawdust or logs with any chemical additives Manufactured logs made o...

Страница 17: ...ires more of the painted surfaces reach the curing temperature of the paint The smell of curing paint does not disappear until you have burned one or two very hot fires Burn one or two small fires to begin the curing and conditioning process Then build bigger and hotter fires until there is no longer any paint smell from the fireplace Once the paint smell disappears your fireplace is ready for ser...

Страница 18: ...ling across the two logs and some larger kindling across those log cabin style Light the newspaper 4 3 4 Using Fire Starters Many people like to use commercial fire starters instead of newspaper Some of these starters are made of sawdust and wax and others are specialized flammable solid chemicals Follow the package directions for use Gel starter may be used but only if there are no hot embers pre...

Страница 19: ... from the fireplace and placed in a tightly covered metal container they should be taken outside immediately The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal Ashes normally contain some live charcoal that can stay hot for several days If the ashes are disposed of by burial in soil or otherwise...

Страница 20: ...place This heat surge is welcome when the room temperature is a little lower than desirable but not welcome if the space is already warm Therefore allow each load of wood to burn down so that the space begins to cool off a little before loading Letting the space cool before loading is one of the secrets to clean burning and effective zone heating 4 4 5 Turning Down the Air Supply Once the firewood...

Страница 21: ...n diameter After raking the coals you can lay two pieces parallel to each other corner to corner in the firebox and lay two more across them in the other direction Open the air control fully and only reduce the air after the wood is fully flaming This kind of fire is good for mild weather when you are around to tend the fireplace and should provide enough heat for four hours or more Small fires li...

Страница 22: ...te zone you live in and the time of year The table below provides a very general indication of the maximum burn cycle times you are likely to experience based on firebox volume FIREBOX VOLUME MAXIMUM BURN TIME 1 5 cubic feet 3 to 5 hours 1 5 c f to 2 0 c f 5 to 6 hours 2 0 c f to 2 5 c f 6 to 8 hours 2 5 c f to 3 0 c f 8 to 9 hours 3 0 c f 9 to 10 hours Long burn times are not necessarily an indic...

Страница 23: ... can be easily removed when the fireplace is cool by wiping with a damp cloth or paper towel and then drying Never try to clean the glass when the fireplace is hot In spring and fall when the fireplace is run at lower temperatures you may see some light brown stains forming especially at the lower corners of the glass This indicates that the fire has been smoky and some of the smoke has condensed ...

Страница 24: ... 1 To adjust the door handle parallelism with the door loosen lower screw A and upper screws B and slide the door lock assembly up or down see 1 2 To get a proper door seal using a ratchet with a 5 16 socket turn the lower screw A clock wise to reduce the door handle pressure or counter clock wise to increase the door handle pressure see 2 5 1 4 Door Alignment To align open the fireplace s door an...

Страница 25: ...tallation and Operation Manual 25 Using a flat screwdriver turn the adjustable hinge rods in the direction shown to adjust the doors Tighten all door hinge pressure screws when they are at the desired positions ...

Страница 26: ... press the gasket into the groove Do not stretch the gasket as you place it Leave the gasket about 1 2 long when you cut it and press the end into the groove Tuck any loose fibres under the gasket and into the silicone Close the door and do not use the fireplace for 24 hours Location Length Dimension Door frame 81 206 cm Round 1 2 54 cm The glass used in the HE250 is 5 mm thick of dimension 25 3 8...

Страница 27: ...aint the fireplace when the unit is hot Painted surfaces can be wiped down with a damp cloth Plated surfaces may be scratched by abrasive cleaners To maintain the finish at its original brilliance use only a damp soft cloth to clean plated surfaces If the paint becomes scratched or damaged you can give your wood fireplace a brand new look by repainting it with heat resistant paint Before painting ...

Страница 28: ...l fire authority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire 5 2 3 Cleaning the Chimney Chimney cleaning can be a difficult and dangerous job If you don t have experience cleaning chimneys you might want to hire a professional chimney sweep to clean and inspect the system for the first time After having seen the cleaning process you can d...

Страница 29: ...ion of Secondary Air Tubes and Baffle for details 5 2 5 Chimney Fire Regular chimney maintenance and inspection can prevent chimney fires If you have a chimney fire follow these steps 1 Close the fireplace door and the air intake controls 2 Alert your family of the possible danger 3 If you require assistance alert your fire department 4 If possible use a dry chemical fire extinguisher baking soda ...

Страница 30: ...INES AND OR WEB SITES MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS WHERE ANY SUCH CHANGES ARE PLANNED STOVE BUILDER INTERNATIONAL INC SHOULD BE CONTACTED IN ADVANCE ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY VIOLATES CSA B365 CANADA AND ANSI NFPA 211 USA CONNECTION BETWEEN A 210...

Страница 31: ...a the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22 1 Canadian National Electrical Code are to be followed in the absence of local code requirements In the USA the ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code requiremen...

Страница 32: ...location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts optional outside air kit and chimney If possible you should choose a location where the chimney will pass through the house without cutting floor or roof rafters B Usuall...

Страница 33: ...wer angle for the full width of the floor protection must be protected 2 horizontally and vertically E by a non combustible material For example a sheet metal not included Apart from these two corners the sheet metal does not have to cover the rest of the wall between the base of the fireplace and the floor Note that the non combustible hearth extension floor area must extend at least 18 457 mm in...

Страница 34: ...34 HE250 Installation and Operation Manual ...

Страница 35: ...HE250 Installation and Operation Manual 35 In the case where F would be equal to 4 it is suggested that the sheet metal between the base of the fireplace and floor be in one piece ...

Страница 36: ...ld match or exceed the height of the floor protection MINIMUM MEASUREMENT E 2 51 mm A noncombustible floor protection with R value insulation equal to or greater than 1 00 must be installed in front of the unit For more details see Section 6 3 2 Minimum Hearth Extension Requirements The use of an R value is convenient when more than one material is going to be used in the hearth extension to cover...

Страница 37: ...e combination is acceptable For R values of some selected materials see Appendix section Example Required floor protection R of 1 00 Proposed materials four inches of brick and one inch of Durock board Four inches of brick R 4 x 0 2 0 8 plus 1 inch of Durock R 1 x 0 52 0 52 0 8 0 52 1 32 This R value is larger than the required 1 00 and is therefore acceptable In the case of a known K and thicknes...

Страница 38: ... Cement mortar 5 00 0 2 Common brick 5 00 0 2 Face brick 9 00 0 11 Marble 14 3 20 00 0 07 0 05 Ceramic tile 12 5 0 008 Concrete 1 050 0 950 Mineral wool insulation 0 320 3 120 Limestone 6 5 0 153 Ceramic board Fibremax 0 450 2 2 Horizontal still air 1 8 0 135 0 920 Information as reported by manufacturers and other resources For a 1 8 thickness You cannot stack horizontal still air to accumulate R...

Страница 39: ...oor area must extend at least 16 406 mm in front of the hearth A and at least 8 203 mm on each side of the door opening D The joint between the hearth extension and the fireplace hearth needs to be made of non combustible material such as sheet metal not included CLEARANCES A 16 406 mm B 41 5 1054 mm C 8 203 mm ...

Страница 40: ... B Frame the fireplace with vertical studs at the sides of the fireplace running from floor to ceiling Position the studs back from the front edge of the fireplace a space the thickness of the facing material so that the facing can be installed flush with the fireplace facing Frame headers between the vertical studs only as follows Place the front facing headers in 2 3 or of a depth no more than t...

Страница 41: ...plate installation CLEARANCES A 4 7 8 124 mm B 8 203 mm C 5 127 mm D 80 2032 mm MEASUREMENTS E 37 7 8 962 mm F 24 3 4 629 mm G 1 3 8 35 mm MAX When drywall panels or any other finishing material inside the chase around the fireplace is to be used add its thickness to the measurement ...

Страница 42: ... this area Non combustible material only in this area MINIMUM MEASUREMENTS FOR FRESH AIR INTAKE L MINIMUM MEASUREMENTS FOR FORCED AIR KIT J J 12 305 mm 18 457 mm H 12 305 mm 18 457 mm When drywall panels or any other finishing material inside the chase around the fireplace is to be used add its thickness to the measurement The fresh air intake kit and the forced air distribution kit may be install...

Страница 43: ...al inside the chase around the fireplace is to be used add its thickness to the measurement Values M and N are minimum measurements They may need to be increased to alloy installation of a fresh air intake kit or forced air kit or depending on the finish material used CLEARANCES A 3 76 mm maximum B 5 5 8 143 mm minimum C 24 610 mm minimum ...

Страница 44: ...mantel shelf or to install a combustible mantel shelf refer to table and figure below For example a mantel shelf with a 6 depth 152 mm C value must be installed at least 58 1473 mm B value above the bottom of the fireplace see figure below Different mantel shelf dimensions are listed in the following table However no combustible mantel shelf can be installed at less than 58 1473 mm above the botto...

Страница 45: ...HE250 Installation and Operation Manual 45 CLEARANCES A 80 2032 mm SHELF POSITIONING B C 58 1473 mm 6 152 mm 60 1524 mm 8 203 mm 62 1575 mm 10 254 mm 64 1626 mm 12 305 mm ...

Страница 46: ...usion measured from the inside door frame Wall in front of fireplace 48 Ceiling 80 in 2 03 m measured from the base of the fireplace Fireplace enclosure Back wall 0 Sides 0 Floor under the fireplace 0 Chimney 2 50 mm Combustible shelf 58 147 cm measured from the base of the fireplace for a shelf with a depth of 6 15 cm or less 64 163 cm measured from the base of the fireplace for a shelf with a de...

Страница 47: ...east 1 m 3 ft above the highest point of contact with the roof and at least 60 cm 2 ft higher than any roof line or obstacle within a horizontal distance of 3 m 10 ft 8 4 The Relationship Between the Chimney and the House Because the venting system is the engine that drives the wood heating system it must have the right characteristics The signs of bad system design are cold backdrafting when ther...

Страница 48: ...itions must be optimal interior chimney minimum height of 18 before any offset etc Additional height will increase drafts and will decrease the tendency to smoke 5 All chimney installations must include at least one support Reducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands This can be achieved by having the chimney supported by the ...

Страница 49: ...HE250 Installation and Operation Manual 49 11 Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact with combustible materials or damage the chimney ...

Страница 50: ...is located in the same non chase or within the same area we suggest that their terminations be separated by at least 16 410 mm horizontally and 18 460 mm vertically This separation is to prevent smoke migrating from one chimney to another 18 457 21mm 18 457 2mm 16 406 4mm 16 406 4mm 18 457 2mm ...

Страница 51: ...llation Some non illustrated parts may be required 8 6 1 Examples of Typical Chimney Installation A To insure a good draft it is recommended to have a length of 18 inches from the top of the unit to the first offset However starting using a 30 or 45 elbow is also approved B Mandatory measure of 15 ft from the bottom of the fireplace to the top of the outside chimney ...

Страница 52: ...52 HE250 Installation and Operation Manual Direct installation Exterior offset installation ...

Страница 53: ... each ceiling floor separation through which the chimney will pass At the attic level install a radiation shield from above C 3 Follow the chimney s manufacturers instructions and place the first chimney length on the fireplace You must use an anchor plate A supplied by the chimney manufacturer before installing the first chimney length Continue installing chimney lengths making sure to lock each ...

Страница 54: ...ng nails 6 Place the storm collar E over the flashing and tighten it with the bolt supplied Finally seal the joint between the storm collar and the chimney using silicone caulking 7 Install the chimney cap G 8 When a ventilated roof flashing is installed precautions are to be taken not to caulk or seal the ventilating openings THE STRUCTURAL INTEGRITY OF THE FLOOR WALL AND CEILING ROOF MUST BE MAI...

Страница 55: ...hs to achieve the required offset Lock the chimney lengths together according to the chimney manufacturer s instructions It is recommended to use three 3 12 mm screws If the offset length is made of two 2 chimney lengths or more Olympia Chimney require that you use an offset or roof support halfway up the offset If penetrating a wall install a wall radiation shield supplied by the chimney manufact...

Страница 56: ...k Dura Plus HTC AC Triple Wall Dura Plus You can get a kit of four 4 rafter protector AC03510 from your dealer Each rafter is made of 22GA galvanized steel 10 44 W x 5 126 H CHIMNEY MANUFACTURERS BRAND TYPE INNER DIAMETER Olympia Chimney SBI Venting Division Ventis 1 Solid Pack 6 15 cm SBI Venting Division Nexvent 1 Solid Pack 6 15 cm Olympia Chimney Champion Chimney System 1 Solid Pack 6 15 cm Ol...

Страница 57: ...t be used on a roof to support the chimney 2 It may be used on a floor ceiling or roof above an offset to support the chimney above the offset 3 It may be used on a floor ceiling or roof as a supplementary support For roof support installation refer to the instructions provided with the support by Olympia Chimney who provide the maximum height of chimney that can be supported by the support Make s...

Страница 58: ...t correct installation of the liner 2 The clearance to combustible must be a minimum of 1 between the outside of the masonry and any wood framing or loose insulation 3 The chimney must be built in accordance with the current building code 4 No other appliance can be connected to the same chimney Installation The chimney must be relined with a Forever Flex or Hybrid stainless steel liner of the sam...

Страница 59: ...ry chimney until you reach the hole level 5 Install the CVA CPEC06 on the elbow or chimney section 6 Slide the liner assembled with the CACLF6 CUCHF6 through the hole performed in Step 2 7 Install the insulation of the insulated liner adapter over the liner 8 Insert the stainless steel tube of the insulated liner adapter over the insulation 9 Connect the CACLF6 CUCHF6 to the CVA CPEC06 10 Seal the...

Страница 60: ...cted by wind pressures on the house Contrary to commonly expressed concerns almost all tightly sealed new houses have enough natural leakage to provide the small amount of air needed by the fireplace The only case in which the wood fireplace may not have adequate access to combustion air is if the operation of a powerful exhaust device such as a kitchen range exhaust causes the pressure in the hou...

Страница 61: ...distribution kit Traditional AC01375 Hot air gravity distribution kit Modern with adjustable pipes AC01389 Forced air distribution kit Hot air gravity distribution kit Traditional AC01375 The kit includes 2 x hot air outlets grilles A and frames B 2 x 90o elbows C 6 x steel brackets D with fastening screws E and self tapping screws F Parts not included in the kit 2 x 8 rigid ducting G ...

Страница 62: ...GRILLE WITH ELBOW The safety rules and installation procedures for both hot air gravity distribution kits AC01375 AC01389 are the following Minimum height 68 1 7 m Minimum distance from ceiling 12 30 cm Maximum length 10 3m The minimum height of the hot air ducting must be measured from the floor to the top of the hot air grilles ...

Страница 63: ...he hot air grilles can be installed in the same room as the fireplace or one or both of the grilles can be installed in adjacent or upper rooms Installing the ducts at different elevations will tend to exhaust more heat out of the higher grilles ...

Страница 64: ...les on top of the fireplace Then cut and remove the insulation in order to obtain two 8 dia openings Then remove the plates closing up the 8 dia holes inside the fireplace 2 Secure the 6 steel brackets B with 6 screws provided C on top of the fireplace 3 for each ducting Insert the ducting A not provided into each opening and secure it in place using the steel brackets B installed previously with ...

Страница 65: ...r outlets grilles to the frames with screws 4 Maintain at least a 2 50 mm clearance between the ducts and the firestop the required hole size for the hot air grilles outlet is 8 8 210 mm 210 mm 5 The maximum number of elbows in a run of duct is two 6 Maintain at least 10 254 mm clearance from the outlet grille framing to a combustible ceiling side wall or mantel 7 When passing through a combustibl...

Страница 66: ...heat 10 Do not use tees or any other components than the ones specifically listed here 11 All ducts must extend upwards or horizontally Never route the ducting downwards 12 The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings 13 Always install the two outlet grilles when using the hot air gravity distribution kit and blo...

Страница 67: ...n kit Modern with adjustable pipes AC01389 The kit includes Decorative plate A Adjustable frame B Heat distribution box C Telescoping section D Anchor plate E All screws are included Parts not included in the kit 8 rigid ducting if required according to the desired height ...

Страница 68: ...68 HE250 Installation and Operation Manual DIMENSIONS OF HEAT DISTRIBUTION BOX DIMENSIONS OF ADJUSTABLE DECORATIVE PLATE ...

Страница 69: ...HE250 Installation and Operation Manual 69 DIMENSIONS OF ASSEMBLED HEAT DISTRIBUTION BOX AND ADJUSTABLE DECORATIVE PLATE DIMENSIONS OF TELESCOPING SECTION Max Min ...

Страница 70: ...8 dia holes on top of the fireplace Then cut and remove the insulation in order to obtain two 8 dia openings Then remove the plates closing up the 8 dia holes inside the fireplace 2 Secure the 2 anchor plates C with 8 screws provided B on top of the fireplace 4 for each anchor plate Insert the telescoping section A into each anchor plate and secure it with 6 other self tapping screws provided B ...

Страница 71: ...ction Determine the needed height and secure the two parts of the telescoping sections together with 3 self tapping screws provided Insert the adjustable frame D in the heat distribution box C press it against the non combustible finishing material and secure with 4 screws into the heat distribution box Set the decorative plate E to the adjustable frame D ...

Страница 72: ... the forced air kit on the emissions of fine particles Due to the design of our appliance and more specifically to the temperature sensor that is installed to control stops and starts the forced ait kit does not affect the emission results In fact this option promotes the recovery of excess heat to later redistribute it to other rooms During our testing it was noted that the convection blowers und...

Страница 73: ...0 Installation and Operation Manual 73 APPENDIX 2 BLOWER MAINTENANCE OR REPLACEMENT 1 Open the bottom louver A 2 With a short square head screwdriver remove the 4 screws C holding in place the heat shield B ...

Страница 74: ...74 HE250 Installation and Operation Manual 3 Remove and keep the heat shield B and the 4 screws C 4 Cut the Tie wrap D ...

Страница 75: ...ps in reverse order to reinstall the fan Blower connection Have the wiring installed by a qualified electrician Connect the wires from the power outlet to the terminal block making sure that the white wire matches the white wire on the terminal Connect the black wire with the black wire of the terminal block The ground green or skinned wire must be attached to the fireplace metal frame ...

Страница 76: ...tall the door overlay See figure below for installation instructions Position the overlay A and on the door frame and secure from the inside of the door using the 6 included screws B and bolts C To facilitate the installation do not tighten the screws until they are all installed Note It is not necessary to remove the glass or any other component to install the overlay ...

Страница 77: ...ncreasing substantially the quantity of incoming fresh air THE INSULATED FLEXIBLE PIPE LENGTH SHOULD BE SUFFICIENT AND HAVE A CONFIGURATION TO AVOID CONDENSATION THE OUTSIDE WALL TERMINATION MUST NOT BE INSTALLED AT MORE THAN 50 OF THE TOTAL HIGHT OF THE CHIMNEY AND AT THE MOST 10 FT 3 M ABOVE THE BASE OF THE FIREPLACE THE FRESH AIR MUST COME FROM OUTSIDE THE HOUSE THE AIR INTAKE MUST NOT DRAW AIR...

Страница 78: ...e of the appliance most common 2 On the right side at the back of the appliance 3 On the right side under the appliance 1 Using a Philips screwdriver remove the four screws holding the rectangular plate A on the right of the fireplace jacket If the location 2 or 3 has been chosen use pliers to remove the knock out 2 Secure the fresh air intake kit adapter B on the fireplace jacket using the 4 scre...

Страница 79: ...e of the adjustable pipe clamps C Secure the other end of the pipe to the outside wall termination E using the second adjustable pipe clamp C The outside wall termination E must be installed outside of the building Use the length required for your installation while respecting the maximum length of 30 ft 9 m To avoid condensation it is recommended to use an insulated pipe long enough and containin...

Страница 80: ...to the wall with screws as shown bellow Place the insulated pipe over the register tube and over the fireplace outside air connector At each end carefully pull back the insulation and plastic cover exposing the flexible pipe Attach the flexible pipe using pipe clamps For a better seal you may also use aluminum tape Wrap the tape around the joint between the flexible pipe and the air inlets Careful...

Страница 81: ...r opening Lean the upper part of the firescreen against the top door opening making sure to insert the top firescreen bracket behind the primary air deflector as in DETAIL A Lift the firescreen upwards and push the bottom part towards the stove then let the firescreen rest on the bottom of the door opening Warning Never leave the stove unattended while in use with the firescreen ...

Страница 82: ...STALLATION OF SECONDARY AIR TUBES AND BAFFLE REMOVABLE PARTS A Cotter pins x4 B Air tubes x4 C C cast baffle x1 D Baffle insulation x1 E Baffle insulation weight x1 1 Using a ratchet key and a Torx T 30 unscrew the two Torx screws B holding up the andiron A ...

Страница 83: ...HE250 Installation and Operation Manual 83 2 Remove the floor refractory slab C 3 Using a power screwdriver and hex tip 5 16 remove the slab holder D and the left refractory slab E ...

Страница 84: ...ar tube lean and insert the right end of the secondary air tube into the rear right channel hole Then lift and push the tube towards the right inside the hole in the right channel 5 Align the notch in the left end of the tube with the tab of the left air channel hole ...

Страница 85: ...he tube Then bend the tabs on the pin to keep in place 7 Repeat steps 4 5 and 6 for the two tubes in the back then install the baffle Then install the two front tubes 8 To remove the tubes use the above steps in reverse order Note that secondary air tubes can be replaced without removing the baffle board ...

Страница 86: ... be minimized by proper curing as described in First Fires They will not normally diminish the effectiveness of the refractory slabs If large cracks develop then the refractory slabs should be replaced To replace the refractory slabs follow these steps 1 Using a ratchet key and a Torx T 30 socket unscrew the two Torx screws B holding up the andiron A 2 Remove the floor refractory slab C ...

Страница 87: ...Operation Manual 87 3 Using a power screwdriver and hex tip 5 16 remove the slab holders D and the refractory slabs E and F 4 Remove the rear refractory slab G To install new refractory slabs follow the above steps in reverse ...

Страница 88: ...88 HE250 Installation and Operation Manual APPENDIX 8 EXPLODED DIAGRAM AND PARTS LIST ...

Страница 89: ...801 BLACK OXIDE SPRING WASHER 1 12 30192 STAR RING 10 X 410 395 OD 025 020 THICK 1 13 30359 HEX NUT 10 24 ZINC 1 14 SE66582 REPLACEMENT GLASS WITH GASKET 13 x 25 3 8 1 15 AC06400 3 4 FLAT X 6 BLACK SELF ADHESIVE GLASS GASKET 1 16 PL66575 LEFT DOOR HOLDER 2 17 PL66576 DOWN GLASS RETAINER 2 18 30124 SCREW 8 32 X 5 16 TRUSS QUADREX ZINC 10 19 AC06730 SILICONE AND 1 X 8 BLACK DOOR GASKET KIT 1 20 3006...

Страница 90: ...ACTORY BRICK PANEL RETAINER 2 56 PL53132 FRONT SECONDARY AIR TUBE 1 57 PL53133 FRONT CENTER SECONDARY AIR TUBE 1 58 PL53134 REAR CENTER SECONDARY AIR TUBE 1 59 PL53135 REAR SECONDARY AIR TUBE 1 60 SE36250 STAINLESS STEEL COTTER PIN 1 8 X 1 1 2 12 UNITS 4 61 30026 THREAD CUTTING SCREW 10 24 F 5 8 HEX WASHER HEAD 5 62 PL53041 REAR REINFORCEMENT 1 63 21296 C CAST BAFFLE 24 3 16 X 20 5 8 X 14 3 4 X 1 ...

Страница 91: ...y this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in no event be r...

Отзывы: