INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE  435 x 275 mm

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE  435 x 275 mm

Please read these instructions

Thank you for purchasing your new EGLO Bathroom Heater/Exhaust/Light. 

To ensure a safe and successful installation, please make sure to read this manual, ensure 

it is on hand for your installer to refer to and keep in a safe place for future reference.

For your safety

1.

ALL electrical work should only be carried out by a licenced electrical contractor 

in accordance with AS NZS 3000.

2.

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory, or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

the use of the appliance by a person responsible for their safety.

3.

Before commencing any electrical work, ensure the power is disconnected 

and/or the mains switched off at the power supply.

4.

This product has been designed to operate on a nominal supply voltage of 230 

-240V AC.

5.

The Bathroom Heater/Exhaust/Light unit must be earthed.

6.

Disconnection may be achieved by having the plug accessible, or by 

incorporating a switch into the fixed wiring in accordance with wiring rules. The 

Bathroom Heater/Exhaust/Light must be isolated by means of a plug or all-pole 

disconnection switch with a contact separation of at least 3mm in each pole.

7.

Use the Instant Heat only as described in this instruction, other use may cause 

fire or electric shock.

8.

This product has been designed for INDOOR domestic or similar uses and is not 

suitable for a commercial installation. It is not suitable for use in an environment 

heavily-laden with dust and/or corrosive areas. Under these conditions the life of 

the fan motor can be significantly reduced.

9.

The bulbs are hot when in use. Do not touch the infrared bulbs with any part of your

body when in use. Allow all bulbs to cool sufficiently before touching or replacing.

10.

The bulbs on this product should be tightened until fit is secure. Over tightening 

may damage the bulbs and under tightening may result in hot joints.

11.

This product contains no serviceable parts and no attempt should be made to 

repair this product.

12.

Regular cleaning of dust and contaminants should be done with ONLY a damp 

cloth, solvents should never be used.

13.

This product has been designed to operate in ambient temperatures 

up to 40°C.

14.

This product is to be installed so that switches CANNOT be touched or 

operated by a person in the bath or shower.

15.

Joists, beams and rafters must not be cut, notched or damaged in the 

installation of this product.

16.

Airflows listed in this product indicate the product performance. Refer to the 

BCA (Building Code of Australia), or similar, for the appropriate number of 

room air changes required for a particular installation.

17.

Ventilation products must have an adequate source of external air to ensure 

rated performance can be achieved.

18.

The ducting of the Bathroom Heater/Exhaust/Light must not be put in the 

same flue as air-fuelled water heaters or open-fire appliances.

19.

This product should not be enclosed in thermal insulation as it may cause the 

unit to overheat.

20.

This product should not be operated for more than 40 minutes continuously, 

turn off when not in use.

21.

The terminals on this product should not be over-tightened. Over tightening 

may damage the product, under tightening may result in hot joints.

22.

This unit is for ceiling mounting only, a minimum 2.1m above floor level. 

Do not install in wardrobes or within 250mm of walls. There is a danger of 

combustion if placed too close to curtains or other flammable materials.

23.

Consideration must be taken in the installation of ducts to ensure that 

condensation that will form in the duct will not run back in to the fan housing.

24.

The material in this product may vary in colour from batch to batch. Colour 

matching from one batch to another cannot be guaranteed.

25.

After installation this product must be tested as required by the appropriate 

government and/or statutory regulations.

26.

Ventair Pty Ltd will not be liable for any advice given to the consumer from any 

of our suppliers or third parties, related or otherwise.

27.

The important safeguards and instructions in this manual are not designed to 

cover every possible condition or circumstance. It is understood that common 

sense, caution and care are factors that cannot be built into the product, those 

using and maintaining this product must supply these factors.

Parts list

Operation unit

1 piece

Infrared lamp (E27)

4 pieces

13 W LED Panel Light

1 piece

Installation instruction & 

hole-cut-ting template

1 piece

Ventiduct kit

1 set

Duct clip

1 piece 

Ø

120mm, 2 pieces 

Ø

150mm

Switch

1 piece

Exterior vent

1 piece

Specifications

Model number

204156/204155

Rated Voltage

230-240 VAC

Rated Frequency

50 Hz

Rated Power

1080-1180 W

EGLO Lighting has a policy of continual product improvement and development, 

dimensions, hardware and designs may change to reflect this policy. EGLO reserves 

the right to discontinue or change product specifications & designs at any time 

without notice and without incurring obligations. The images including all features 

and specifications in this manual are for illustrative purposes only. Product details, 

images & line drawings may vary depending on specific product models.

Installation considerations

The unit must not be installed directly above a shower or bath. The unit must 

not be installed where water may splash onto the bulbs.

The unit must not be installed beneath a fixed socket.

The unit is designed for installation on flat ceilings only. Do not install on 

sloping ceiling or on a vertical wall.

The infrared heating bulbs are most effective when you are standing directly 

beneath them, install the unit above where you would stand to dry yourself. 

To obtain the best heating effect, we recommend there is between 2.3 and 2.7 

metres from the bulbs to the floor.

For the exhaust fan to work effectively, replacement air of a volume equivalent 

to what is being extracted must be able to enter the room. If the room is 

airtight, we suggest to leave a door or window open slightly to allow enough 

airflow.

Before commencing installation, check the ceiling space to ensure there are 

no obstructions such as ceiling joists, and that there is sufficient height 

clearance for the housing.

Installation

1.

Turn the power OFF.

2.

Locate a desired position on the ceiling, do not cut a hole yet.

3.

As the duct is only 3.0m, make sure that the distance from the centre of the 
installation position is not more than 3.0m from the exterior vent outlet. It is 
not recommended to use ducting longer than 3.0m as this will lower the 
performance of the exhaust fan. Check desired position suits duct length. 

Fig.

 1

4. 

Locate a position for the exterior vent on the wall not more than 3.0m from 

the unit, and allows the ducting to remain straight. 

(Refer Fig. 1)

Fig.

 2

5.

Place this template against the ceiling and use it to mark the hole outline on 

the ceiling, ensuring there is minimum 250mm between the edges of the unit 

and any wall, and minimum cavity height of 250mm. Cut the hole for the unit. 

(Refer Fig. 2)

6.

Keep unit clear from insulation, use a barrier to keep loose-filled insulation 

material away from unit.

7.

Cut a 155mm diameter hole for the exterior vent outlet.

8.

Connect one end of the ducting to the exterior vent with the duct clips 

provided, and let the other end enter the room through the hole into the 

vent hole and seal the space around the hole.

9.

Remove all bulbs from the unit, unclip the internal fascia retaining springs 

inside the housing, unplug the LED at the connector and remove the fascia.

10.

Connect one end of the interconnecting cable wire with the switch panel.

Fig.

 3

11.

Open the terminal block cover on the housing and make connections as per 

wiring diagram and reattach the terminal block cover. (Refer Fig. 3)

12.

Attach the end of the ducting to the adapter, and fit the adapter to the unit 

outlet, and secure with the duct clips provided.

HEATFLOW

Bathroom Heater/Fan/Light

Model 204156/204157

Installation Manual

BY VENTAIR PTY LTD

SIERRA

PREMIUM HEAT, LIGHT AND EXHAUST

3 1

in

MR4DXWH / MR4DXBL

the Manrose Sierra Premium Heat, Light and Exhaust unit.

The ducting of the Manrose Sierra Premium Heat, Light and Exhaust unit must 

not be put in the same flue as air-fuelled water heaters or open-fire appliances.

Ventair Pty Ltd has a policy of continual product improvement and development, 

dimensions, hardware and designs may change to reflect this policy. Ventair Pty Ltd 

reserves the right to discontinue or change product specifications  and designs at 

any times without notice and without incurring obligations. The image including all 

features and specifications in this manual are for illustrative purposes only. Product 

details, images and line drawings may vary depending on specific product model.

Safety Considerations

Tri-Colour Downlight

The Infrared heating bulbs are most effective when you are standing directly 

beneath them, install the unit above where you would stand to dry yourself. 

To obtain the best heating effect, we recommend there is between 2.3 and 2.7 

metres from the bulbs to the floor.

For the exhaust fan to work effectively, replacement air of a volume equivalent 

to what is being extracted must be able to enter the room. If the room is 

airtight, we suggest to, leave a door ajar, increase the gap under an internal 

door (min 20mm) or add an return air vent into the lower section of the door. 

Note: Opening a window in cold weather conditions, may increase the incidence 

of steam production and is therefore not a preferred option.

Before commencing installation, check  the ceiling space to ensure there are no 

obstruction such as ceiling joists, and that there is sufficient height clearance for 

the housing.