Operating and installation instructions
Connection of 100-240VAC
and 12VDC can not be done
simultaneously (Figure N).
NOTE! 12VDC voltage must not exceed
between 10 - 13,6VDC.
NOTE! For 12VDC always use switches
intended for direct current, C.
N.
O.
No 100-240V wiring may
penetrate the electronics
portion (Figure O).
Svara auto:
12VDC (switch C always)
Continuous trickle ventilation, automatic boost at elevated
humidity levels, and via the integrated light sensor.
Svara on/off operation through remote
switch:
(Can be combined with backdraft shutters)
12VDC
Must be selected via Vent-Axia Connect App.
Start / stop via manual switch C.
Svara humidity controlled:
(Can be combined with backdraft shutters)
12VDC (switch C always)
Must be selected via Vent-Axia Connect App.
Trickle setting, automatic start / stop
on changes in humidity levels.
ELECTRICAL CONNECTION 12VDC