Start Up 

Sentinel Kinetic MVHR Installation & Commissioning 

18

 

                   Indoor Temp Screen 

From the Normal Airflow screen, simply press the 

 

button until the Indoor Temp screen is displayed. 

The Indoor Temp screen enables you to choose the 
target room temperature in degrees Centigrade – only 
displayed when the bypass is fitted. 

Selectable range is 

16-40

 (

25

 default).  

Return to the normal display by pressing the 

 button  

or leave to timeout and return automatically after 2 
minutes. 

This function will only work when the Summer Mode is 
set to on. 

Indoor Temp 
25 C 

Outdoor Temp Screen 

 

From the Normal Airflow screen, simply press the 

 

button until the Indoor Temp is displayed. Press 

 

button to choose the required temperature and then 
press 

 button again to confirm the entry and this will 

call up Outdoor Temp. 

The Outdoor Temp screen enables you to choose the 
minimum outdoor temperature at which the bypass will 
operate in degrees Centigrade – only displayed when 
the bypass is fitted. 

Use this to prevent cold draughts being introduced. 

Selectable range is 

5C – 20C

 (

14C

 default).  

Return to the normal display by pressing the 

 button  

or leave to timeout and return automatically after 2 
minutes. 

This function will only work when the Summer Mode is 
set to on. 

Outdoor Temp 
14 C 

 
 

 

 

 
 

 

 

Содержание Sentinel Kinetic 200Z

Страница 1: ...009 Vent Axia Limited All rights reserved Sentinel Kinetic 200Z 200ZH 300ZH Installation Commissioning Model Stock Ref N 200Z 448733A 200ZH 449540A 300ZH 449536A PLEASE RETAIN THESE INSTRUCTIONS WITH...

Страница 2: ...g children should be supervised to ensure that they do not play with the appliance INSTALLATION GUIDANCE 1 The installer is responsible for the installation and electrical connection of the sentinel s...

Страница 3: ...ng 19 Overview 19 Commissioning Screens 20 Maintenance 30 Filter Maintenance 30 12 Monthly Maintenance 30 Spares 33 Troubleshooting 34 Diagnosing a Problem 34 Appendix Options and Accessories 35 CO2 T...

Страница 4: ...om If the room is cooler than the set indoor temperature i e you need the room heating and the outdoor air is warmer than the actual room temperature i e the outdoor air could heat your room then the...

Страница 5: ...See Graph below Power AC Voltage Input 220 240 V AC single phase AC Frequency Input 50 Hz nominal Supply Fuse 3 A located in fused spur Product Fuse 2 A located on main PCB Rated Power 175W max 180W m...

Страница 6: ...unting brackets and product documentation Lift and Move the Unit Safely Check the weight of the unit that you are installing Always use appropriate lifting techniques and appliances when moving heavy...

Страница 7: ...ng Mounting Fix the 2 Brackets to the ceiling the fixings must be suitable for the surface type intended concrete wood they must also be compatible for the units weight 200 Z ZH 26 5Kg 300ZH 38 5Kg 20...

Страница 8: ...fully tighten Leave approximately a half turn loose on each of the fixings This will allow each bracket to be moveable until final fitting of the unit and makes any adjustments easier while installing...

Страница 9: ...e configuration 32mm 22mm waste For installations in a ceiling void where it is too shallow for a traditional U Trap configuration Our recommendation is to use a HepVO inline waste valve and Tundish A...

Страница 10: ...Airflow Intake Air from atmosphere Airflow Exhaust Air to atmosphere Attaching the ducting 1 Always use a short piece of flexible ducting 100 150mm long extended to its full length when connecting to...

Страница 11: ...end user or used for commissioning the unit 2 Fit the 15 metre Remote Control cable plug into the cable socket fitted to the Heat Recovery Unit 3 Connect the cable assembly to the Remote Control termi...

Страница 12: ...ed to be switched by a current detector for example detecting a hob being switched on or a temperature sensor for example detecting the flow of hot water Terminal 4 can be used in conjunction with a m...

Страница 13: ...unit fault See the Control Panel for fault code see Service Fault Code Screens on page 34 L Mains Live 220 240 V AC 50 Hz input N Mains Neutral 220 240 V AC 50 Hz input EARTH Mains Earth Earthing con...

Страница 14: ...Turn the power off at the mains supply isolator Wired Remote Control Display Display Normal Airflow 30 Buttons Four buttons on the Control Unit provide the controls for configuring and monitoring the...

Страница 15: ...a percentage of the unit s maximum flow Airflow Units Wireless Control Screen Not available Wireless Control Not Fitted Humidity Sensor Screen The Humidity Sensor screen displays whether the humidity...

Страница 16: ...n be triggered from the wireless transmitter boost switch If the installation has switch sensors is wired to the lighting has Vent Wise sensors Vent Wise momentary switch or if the internal time switc...

Страница 17: ...t Clock Screen From the Normal Airflow screen simply press the button once to access the Set Clock screen The Set Clock Control screen enables you to change the clock settings The clock retains its se...

Страница 18: ...o on Indoor Temp 25 C Outdoor Temp Screen From the Normal Airflow screen simply press the button until the Indoor Temp is displayed Press button to choose the required temperature and then press butto...

Страница 19: ...ooting on page 34 Follow good practice when commissioning the unit Ensure that the system is installed according to the system designers intent incorporating any acoustic ducting that all joints are a...

Страница 20: ...ly 20 Low Extract 20 Ckr Hood Supply 30 Ckr Hood Extract 100 Boost Overrun 15 m Boost Delay 00 m Boost On Off Mon1 00 00 00 00 Boost On Off All Set Humidity Sensor Off Normal On Off Mon Normal On Off...

Страница 21: ...If a security PIN code has been previously set this screen will display Enter the PIN using and buttons Security PIN Note 1 Whilst displaying the Low Normal Boost Supply Low Normal Boost Extract scree...

Страница 22: ...e Normal speed cannot be set below Low speed or above Boost speed setting Normal Extract 30 Low Supply Screen The Low Supply screen enables you to set the Low airflow speed for the Supply fan in order...

Страница 23: ...00 m Boost On Off Screen The Boost On Off screen enables you to set a time for boost to be activated for each day of the week You can set up to three On Off times per day shown as Day1 Day2 and Day3 I...

Страница 24: ...2 sec will copy yesterday s times to today Setting finishes when the last off minutes for Sun are accepted at which point the screen will now show All Set or holding the button for 3 seconds Normal O...

Страница 25: ...e Boost Limit the unit runs at boost airflow Between these limits the unit runs at a proportional airflow Proportional 1 Humidity For a humidity sensor a percentage value must be entered for boost and...

Страница 26: ...dinary switches must not be used In use the Vent Wise Card with three sensors will run hot to the touch albeit well below its maximum temperature If any input is shorted e g used with switch the board...

Страница 27: ...for 15 minutes hour and run for 45 depending on the temperature below 0 C If the supply air temperature is 20 C or below the supply fan switches off and the extract fan continues to run at reduced ra...

Страница 28: ...off for example in conjunction with a smoke alarm No changes may be made to this screen BMS 00 The Security PIN screen enables you top set a four digit personal identification number PIN to access th...

Страница 29: ...off inactive Normal On Off All days set to 0 00 on 00 00 off inactive Set Service No Not set Humidity 70 Proportional 1 Humidity Boost Normal 60 CO2 Boost 2000 ppm Normal 1000 ppm Temperature Boost 2...

Страница 30: ...sing a vacuum cleaner if necessary 3 Replace the filters and cover plates 4 Reset the automatic message press and hold the and buttons for 5 seconds 12 Monthly Maintenance Item Action Fan Filters Inte...

Страница 31: ...te the mains power supply and remove the Filter access Panels and Filters Undo the securing screws and remove the Cover Stage 2 Loosen the Condensate Pipe Jubilee Clip and remove Pipe from Condensate...

Страница 32: ...Caution Keep the Tray as horizontal as possible as this may contain condensate Stage 5 Remove the two Heat Exchanger fixing Brackets and Heat Recovery Cell Note Take care when removing the Heat Recov...

Страница 33: ...and attention is retained in re applying all fixings to their previous locations Spares The following spares can be ordered from Vent Axia Description Part No 200Z 200ZH Part No 300ZH Filters 2 per p...

Страница 34: ...Table 4 Fault Codes The Room Too Cold screen displays the status of the fan If the heating system in the building fails or is switched off and the internal temperature drops below 5 C the unit will st...

Страница 35: ...ally depending on the temperature and relative humidity levels in the extracted air whilst avoiding nuisance tripping at night time when temperatures drop and relative humidity naturally rises The uni...

Страница 36: ...5 Control Typology Local Demand Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...n subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage p...

Отзывы: