READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION.
INSTALLATION AND WIRING INSTRUCTIONS SHOULD BE LEFT WITH END USER.
Air moving equipment may present mechanical, electrical or noise hazards. To minimize
risks associated with these potential hazards, it is essential that safety, installation,
operation and maintenance instructions are followed. Implementation of these
instructions should always be undertaken by technically competent personnel.
Potential mechanical hazards must be eliminated by guarding against access to the
rotating parts whilst the air moving equipment is operating. A range of guards are
available for this purpose from Vent-Axia.
Installation work, both mechanical and electrical, must be undertaken in accordance
with the safety and installation instructions before switching on the unit.
Maintenance work should not be attempted before first switching off and isolating the
fan and its control from the electrical supply and ensuring that it cannot be accidentally
turned back on again. It is essential to ensure that rotating parts have come completely
to rest before maintenance work commences.
Air moving equipment may generate unacceptable noise levels when in operation. It
may be necessary to take appropriate action to reduce sound levels. A range of products
are available for this purpose from Vent-Axia.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge unless they
have been given supervision or instruction concerning use of this appliance by a person
responsible for their safety.
Young children should be supervised to ensure that they do not play with the appliance.
IMPORTANT
1.
All electrical connections should be made by a properly qualified electrician. The
fan must be sited and connected in accordance with current I.E.E Wiring
Regulations, BS7671 (U.K.), or the appropriate standards in your country.
2.
DO NOT use this appliance when the following are generated or present: Excessive
grease or oil laden air, corrosive or flammable atmospheres.
3.
When the fan is installed in a room containing a fuel burning appliance, the
installer must ensure that the air replacement is adequate for both the fan and
the fuel burning appliance.
4.
If a fan is used to supply air into a room, the installer must ensure that the fan
intake is located at least 600mm away from any flue outlet.
5.
Site away from direct sources of heat. Ambient temperature range:
-10oC to
+40oC.
6.
When installing unit, take care not to damage electrical or other hidden utilities.
7.
Check the details on the rating label for correct voltage, frequency, speed, phase
insulation class and IP rating.
Содержание QPTW Series
Страница 7: ...7 Fig 1 QPTW100C QPTW125C QPTW150C QPTW160C QPTW200C QPTW250C QPTW315C Connected to a changeover panel...
Страница 8: ...8 Fig 2 QPTW400C QPTW500C Connected to a changeover panel...
Страница 10: ...10 Fig 4 QPTW400C QPTW500C Connected to a changeover panel and auto transformer controller...
Страница 11: ...11 Fig 5 QPTW400C QPTW500C Connected to a changeover panel and auto transformer controller...