6

WIRELESS CONTROLLER (Available stock ref. 426035)

 

 
The selection switch in the Multivent unit and the switch in the hand held transmitter must be set exactly the same. 
The factory setting is 5678 but it is inadvisable to retain this setting. 
 
 

a)  The Multivent Selection Switch.

 

Located as shown in Fig 3.

 

 
 

 

    

 

 
 
 
 
 
 

b)  The Transmitter Selection Switch 

 

• 

Remove battery compartment cover on the back of the transmitter unit.  

• 

Set the transmitter selection switch to the same number sequence as used for the Multivent receiver, 
see Fig 4. 

• 

Connect battery terminal connector to the battery. 

PP3 9V BATTERY

SELECTION SWITCH

 

 

Fig 3 

Fig 4 

Содержание MV250H(RF)

Страница 1: ...UCTIONS IN CONJUNCTION WITH ILLUSTRATIONS READ AND SAVE THESE INSTRUCTIONS Installation Set up and Operating Instructions Stock Ref N MV250H RF 183010A 80W MV350H RF 183015A 100W Installation and Wiring Instructions for the Multivent Humidistat Extract Fans ...

Страница 2: ...ucts E It is recommended that the connection to the terminal box is made with flexible cable conduit F The Unit should not be sited within 600mm horizontally of or 2250mm vertically of a bath shower tray in accordance with the current I E E Regulations for bathrooms G When the unit is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for...

Страница 3: ...ess transmitter available separately The transmitter is switchable between low medium and high boost speed operation The default power on speed setting is low The transmission signal will function over a range of at least 10m through 2 concrete block beam floors 16 unique code selection features are available to match the transmitter to the Multivent receiver and so avoid any possible cross talk b...

Страница 4: ...e use a suitable adaptor attached using the 4 holes provided 3 Ducting passing through an unheated roof void should be insulated Ducting runs should be as straight as possible and intake ducting should slope downwards from Under the lid Connect ducting to the MULTIVENT spigots and to appropriate ceiling terminations 4 Select the drain spigot required remove the Knockout and connect a suitable drai...

Страница 5: ...ill detected the fan speed increases to high for 15 minutes At the end of this period if the humidity is low the fan returns to its original low setting but if still high the fan reverts back to medium speed for 30 minutes and so on OVER HEATING PROTECTION The MULTIVENT motor is fitted with Standard Thermal Overload Protection This will automatically switch the fan Off in the event of a fault cond...

Страница 6: ...s inadvisable to retain this setting a The Multivent Selection Switch Located as shown in Fig 3 b The Transmitter Selection Switch Remove battery compartment cover on the back of the transmitter unit Set the transmitter selection switch to the same number sequence as used for the Multivent receiver see Fig 4 Connect battery terminal connector to the battery PP3 9V BATTERY SELECTION SWITCH Fig 3 Fi...

Страница 7: ...ium speed for 30 minutes and so on Medium Speed Setting If high humidity is detected the fan speed stays at medium speed for 30 minutes At the end of this period if high humidity is still detected the speed increases to high for 15 minutes and drops back to the original medium speed setting at the end of this period High Speed Setting If high humidity is detected there is no speed change However a...

Страница 8: ...rantee outside the United Kingdom contact your local supplier Vent Axia guarantees its products for two years from the date of purchase against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s opinion replaced without charge provided that the product 1 has been installed and used in accordance with the instructions...