ISOLATE FROM THE POWER SUPPLY PRIOR TO ANY MAINTENANCE AND CLEANING
USER INSTRUCTIONS
• At intervals appropriate to the installation, inspect and clean the fan to ensure there is no build up
of grease or dirt on the impeller or the motor.
• The motor is fitted with sealed for life bearings and does not require lubrication.
DISMANTLING
G1 From the inside, remove the connector socket by lifting up the lever gently with a finger, unplug
the controller cable (wired version only).
G2 Unscrew the indoor grille retaining screw and remove the grille.
G3 Partially unscrew the two side catch screws on the housing and depress the two side catches.
G4 Remove the housing.
G5a Release the Power Supply/Receiver Unit catch, located at the bottom left of the motor body
housing assembly.
G5b Lift the Power Supply/Receiver Unit until the second catch engages. Slide the controller socket
from the housing (wired version only).
G6 Release the motor body housing assembly locking catch located to the left of the connection
socket opening and rotate the motor body housing assembly anti-clockwise until the bayonet
catches disengage.
G7 Withdraw the motor body housing assembly and put to one side, with the impeller facing
upwards.
G8 Remove the impeller with a sharp pull away from the motor.
G9 Unscrew the outdoor grille retaining screw and remove the grille.
CLEANING
IMPORTANT: Keep all electrical components away from water.
G10 Wipe the motor, housing assembly and roof cowl (if fitted) with a damp cloth.
G11 Wash all non-electrical components in warm water and detergent.
Fig. 3
(Wired version only)
Please refer also to the speed controller