2.  Removing the grille.  Firstly remove the front cover by carefully pulling each corner of the front panel until it is 

free to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The 
screws will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1).

 

Lift the inner 

grille from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front 
assembly and Base Housing (Fig 6). 

3.  Remove the Spigot Ring from inside the carton and clip over the Spigot Adaptor, making sure the lip on the 

Spigot Ring locates firmly inside the groove on the Spigot Adaptor (Fig 2)

.

 The Spigot can be repositioned for 

side exit installations by removing the screw and sliding the spigot away from the rear of the Base Housing, 
carefully observing the guide rails (Fig 4). The Spigot can then be rotated and repositioned for side exit using the 
same guide rails and retaining screw (Fig 4)

.

 Ensure that the Spigot Adaptor is firmly located onto the Base 

Housing in the required orientation and the shutter is still securely fastened and fully functional. 

4.  Remove the Skirt and pass the supplied screw fully through the flange of the base housing. Then attach the 3 

supplied Panel Clips (Fig 5) and partially screw into place until they are properly retained (allowing enough gap 
for the panel thickness). 

 

 

5.  Set-up the appropriate speed selection and other features as outlined in 

Section B SETUP.

 

6.  Attach the ducting to the Spigot and locate into the hole in the panel, ensuring the cable is fed into the Base 

Housing and the Panel Clips spring out behind the panel.  

7.  Secure into position by carefully tightening the Panel Clips. It maybe necessary to hold the product centrally in 

the hole while tightening so that no gaps are seen once the cover is on. 

IMPORTANT: If power tools are used, 

set them to the minimum torque setting or preferably use a manual screwdriver. Do not over tighten.

  

8.  Ensure the Impeller rotates freely. 
9.  Select and follow the appropriate wiring diagram in 

Section C WIRING.

 

10.  Replace the inner grille ensuring that the PIR sensor cable (TM model only) is reconnected to the PIR sensor 

PCB (Fig 6). 

 

Replace the front panel.

 

 

11.  Switch the mains power supply on and check the fan is operating correctly. 

 
 

WALL MOUNTING (Surface) 

For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used.

 

1.  Cut a 115mm. 

 hole through the wall, ensuring that there is sufficient space for the product to be installed and 

that the filter (If fitted) can be removed for maintenance.  

2.  Insert the wall sleeve with the smaller diameter sleeve on the room-side and cement both ends into position flush 

with the wall faces. The wall sleeve should be angled downwards, away from the fan, to allow any condensation 
to drain to the outside wall. 

3.  Outside Grille: Using the Back Plate as a template, mark the fixing hole centres on the wall. Drill and plug the 

wall and fix the Back Plate into position.  

4.  Fix the Outside Grille on to the Back Plate (screws provided). Ensure the louvres are pointing downwards. 
5.  Removing the grille. Firstly remove the front cover by carefully pulling each corner of the front panel until it is free 

to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The screws 
will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1).

 

Lift the inner grille 

from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front assembly 
and Base Housing (Fig 6). 

6.  Remove the Spigot Ring from inside the carton and clip over the Spigot Adaptor making sure the lip on the 

Spigot Ring locates firmly inside the groove on the Spigot Adaptor (Fig 2)

.

 Ensure that the Spigot Adaptor is 

firmly located onto the Base Housing and the shutter is still securely fastened and fully functional. 

7.  Set-up the appropriate speed selection and other features as outlined in 

Section B SETUP.

 

8.  Using the Base Housing as a template, mark the fixing hole centres on the wall, carefully sliding the spigot into 

the Wall Liner. Secure the Base Housing into position using the screws and fixings provided ensuring the Skirt is 
located correctly into the Base Housing (Fig 3). 

9.  Ensure the Impeller rotates freely. 
10.  Select and follow the appropriate wiring diagram in 

Section C WIRING.

 

12.  Replace the inner grille ensuring that the PIR sensor cable (TM model only) is reconnected to the PIR sensor 

PCB (Fig 6). 

 

Replace the front panel.

 

 

13.  Switch the mains power supply on and check the fan is operating correctly.  

 

B.

 

SETUP 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE 
POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. 

 

 
 
 
 
 

IMPORTANT 

On first power up, the fan will run through its initialization routine. 
On 

T

HT

 & 

TM

 models the fan will switch on and off during this routine (Including the LED) 

Once complete after approximately 2 minutes, the fan will run as normal. 

Содержание Lo-Carbon SOLO Plus SELV HT

Страница 1: ...ESE INSTRUCTIONS Lo Carbon SOLO Plus SELV Centrifugal Bathroom Toilet Fan Stock Ref N 427485B P 427486B T 427487B HT 427488B TM Installation and Wiring Instructions T IPX7 FAN FAN UNITS 12V DC SELV CLASS III CONTROLLERS 220 240V 50Hz MAINS SUPPLY CLASS II WITH 12V DC SELV OUTPUT ...

Страница 2: ...le of disconnecting all poles having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan connector terminals is made with flexible cable F When the Fan is used to remove air from a room con...

Страница 3: ...y wall However the fan must not be placed where it could be submerged in water or regularly exposed to direct water spray e g from a shower head whether permanently fixed or movable A INSTALLATION PANEL MOUNTING Surface 1 Cut a 105mm hole through the panel ensuring that there is sufficient space for the product to be installed and that the filter If fitted can be removed for maintenance 2 Removing...

Страница 4: ... Brown can be used 1 Cut a 115mm hole through the wall ensuring that there is sufficient space for the product to be installed and that the filter If fitted can be removed for maintenance 2 Insert the wall sleeve with the smaller diameter sleeve on the room side and cement both ends into position flush with the wall faces The wall sleeve should be angled downwards away from the fan to allow any co...

Страница 5: ...LOCKWISE Fig 7 6 HUMIDITY ADJUSTMENT HT model The fan s Humidity Set Point is factory set to switch the fan on at 72 RH Fig 7 i To LOWER the Set Point turn the Humidity Adjuster H ANTI CLOCKWISE This makes the fan more sensitive to RH i e the fan will come on at a lower RH Fig 7 ii To RAISE the Set Point turn the Humidity Adjuster H CLOCKWISE This makes the fan less sensitive to RH i e the fan wil...

Страница 6: ...6 Fig 3 Surface mounting screw hole locations Fig 1 Removing the grille Fig 2 Attaching the spigot Fig 4 Converting outlet spigot for side exit and recess mounting ...

Страница 7: ...M model To remove the cover on TM models the sensor lead must be disconnected Timer adjuster T HT TM Models To reduce time Turn anti clockwise To increase time Turn Clockwise Humidity adjuster HT Model To LOWER the set point Turn Anti clockwise To RAISE the set point Turn clockwise Fig 5 Recess mounting clips In 3 positions LED position Dip switch settings Cable clamp must be used with surface wir...

Страница 8: ... diagram IMPORTANT On first power up the fan will run through its initialization routine On T HT TM models the fan will switch on and off during this routine Including the LED Once complete after approximately 2 minutes the fan will run as normal ...

Страница 9: ...logy CTRL Typology Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either sup...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...eglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and p...

Отзывы: