Warning & Safety Information
Do not install this product in areas where the following may be present or occur:
Excessive oil or a grease laden atmosphere.
Corrosive or flammable gases, liquids or vapours.
Subject to direct water spray from hoses.
Ambient temperatures higher than 40°C and lower
than -20°C.
Possible obstructions that may hinder access to or
removal of the unit.
All wiring must be in accordance with the current IEE wiring regulations BS7671, or
appropriate standards of your country. Installation should be inspected and tested by a
suitably qualified person after completion.
Ensure the mains supply (voltage, frequency and phase) complies with the rating label.
To allow disconnection of the supply after installation the unit should be provided with a
local double pole fused spur fitted with a 3A fuse having a contact separation of at least
3mm. If a unit fitted with a preheater is being installed, a 13A fuse should be used.
Precautions must be taken to avoid the back-flow of gases into the building from the open
flue of gas or other fuel-
burning appliances. Ensure that the unit’s external grilles are a
minimum of 1500mm apart. The exhaust grille should be located at least 600mm away
from any flue outlet. The inlet grille should be located 2000mm away from any flue outlet.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Young children should be supervised to ensure that they do not play with the appliance.
The installer is responsible for the installation and electrical connection of the sentinel
system on site. It is the responsibility of the installer to ensure that the equipment is safely
and securely installed and left only when mechanically and electrically safe.
All regulations and requirements must be strictly followed to prevent hazards to life and
property, both during and after installation, and during any subsequent servicing and
maintenance.
T
he unit’s condensate drain must be connected to the building’s wastewater drainage
system.
Certain applications may require the installation of sound attenuation to achieve the sound
levels required.
The unit must not be connected directly to a tumble drier.
The supply and exhaust valves must be fully opened prior to commissioning.
The intake air must be drawn from the exterior of the property.
The unit should be allowed to stabilise during commissioning for a minimum period of 5
minutes when changing between boost and normal speeds.
This product and associated duct installation should be carried out in accordance with the
Domestic Ventilation Compliance Guide.
Before carrying out maintenance ensure the fan is switched off from the mains before
removing covers.
Caution:- In order to avoid hazard due to inadvertent re-setting of the thermal cut-out, this
appliance must not be supplied through an external switching device such as a timer or
connected to a circuit that is regularly switched off by the utility.
In the event of failure please contact your local supplier.
INFORMATION FOR THE INSTALLER