Warnings & Safety Information 

 

2

 

IMPORTANT SAFETY 
INFORMATION 

 

PLEASE READ THESE 
INSTRUCTIONS 
CAREFULLY BEFORE 
COMMENCING 
INSTALLATION. 

1. Do not install this product in areas 
where the following may be present or 
occur: 
•  Excessive oil or a grease laden 
atmosphere. 
•  Corrosive or flammable gases, 
liquids or vapours. 
•  Subject to direct water spray from 
hoses. 
•  Ambient temperatures higher than 
40

°

C. 

•  Possible obstructions that may 
hinder access to or removal of the unit. 
2. All wiring of the system must be in 
accordance with the current IEE wiring 
regulations BS7671, or appropriate 
standards of your country. Installation 
should be inspected and tested by a 
suitably qualified person after 
completion. 
3. Ensure the mains supply (voltage, 
frequency and phase) complies with 
the rating labels on the inline fans (Not 
provided). 
4. Precautions must be taken to avoid 
the back-flow of gases into the building 
from the open flue of gas or other fuel-
burning appliances. 

5. This appliance is not intended for 
use by persons (including children) 
with reduced physical, sensory or 
mental capabilities, or lack of 
experience and knowledge, unless 
they have been given supervision or 
instruction concerning use of the 
appliance by a person responsible for 
their safety. 
6. Young children should be 
supervised to ensure that they do not 
play with the appliance. 

INSTALLATION GUIDANCE 

1. The installer is responsible for the installation and 
electrical connection of the system on site. It is the 
responsibility of the installer to ensure that the 
equipment is safely and securely installed and left 
only when mechanically and electrically safe. 

2. All regulations and requirements must be strictly 
followed to prevent hazards to life and property, 
both during and after installation, and during any 
subsequent servicing and maintenance. 

 
 
 
Disposal 

This product should not be disposed of with 
household waste. Please recycle where facilities 
exist. Check with your local authority for recycling 
advice.

Содержание HR500IP

Страница 1: ... Axia Limited All rights reserved HR500IP Passive Semi Remote Wall Mounted Heat Recovery Unit with Spigot Connections Installation Instructions Stock Ref N 370447 HR500IP PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT ...

Страница 2: ...building from the open flue of gas or other fuel burning appliances 5 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 6 Young children should be supervised to ens...

Страница 3: ...hieved by using in line duct fans or wall mounted units to suit the length and configuration of ducting systems The unit is compatible with Ø300mm flexible duct and is ideally suited for use with in line fans and external wall louvres Concentric reducers are available to convert inlet and exhaust spigots to 250mm or 200mm diameter for use with alternative sized fans and ducting if required Typical...

Страница 4: ...port of the building fabric if required If used this will automatically produce a 3 slope of the unit away from the inner grille for drainage of any condensate which may form during operation A 22mm drain is situated between inlet and exhaust spigots and should be connected to a suitable drain soakaway Fixing hole opening Supply Extract 370mm 600mm FRONT Ø290 PLAN ...

Страница 5: ...vated will turn red over 6 months It should be used to keep track of when the filter and cell need cleaning replacement Using the self adhesive backing the strip can stuck near the units controls or in a easily visible place A normal cleaning schedule for a unit would be as follows Note The above is the minimum requirement more frequent cleaning intervals may be needed depending on the environment...

Страница 6: ...ff the backing liner and stick the Timestrip to the Unit or near the controls of the unit The location should make it obvious to the person responsible for maintenance that the unit needs attention 3 Once activated the red dye will indicate elapsed time by moving through the white window and past each time marker The progress of the red dye is irreversible and each Timestrip can only be used once ...

Страница 7: ...pology Manual Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side N A Position and description of visual filter warning for RVUs intended for use with filters in...

Страница 8: ...eing found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to ...

Отзывы: