ROUTINE INSPECTION AND MAINTENANCE

ISOLATE THE UNIT FROM THE POWER SUPPLY AND ENSURE THAT IT CANNOT BE ACCIDENTALLY SWITCHED BACK ON

1.  At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up

of dirt or other deposits on the impeller or the motor (Caution – do not dislodge any balance weights which may
be fitted to the impeller). If the fan is handling dust laden air, it is recommended that a filter is installed.

2.  All Vent-Axia acoustic fan motors are fitted with sealed for life bearings and do not require lubrication.

OVERHEATING PROTECTION

The fan motor is fitted with Standard Thermal Overload Protection. This will automatically switch the fan Off in the
event of a fault condition. If this occurs, isolate the fan, check for any obstruction, leave the fan for a short time for
the motor to cool before reconnecting the power supply. If the fault reoccurs, isolate the power supply and call a
service engineer.

Fig. 1

DIMENSIONS (mm)

Содержание ATQ 400-14C

Страница 1: ...TRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS READ AND SAVE THESE INSTRUCTIONS ACOUSTIC TWIN FAN Stock Ref N ATQ 100 12C ATQ 200 12C ATQ 400 14C ATQ 125 12C ATQ 250 12C ATQ 500 14C ATQ 150 12C ATQ 315 1...

Страница 2: ...rt duct runs terminating within 1 5m must incorporate suitable guards unless the fan is mounted higher than 2 3m J This fan should not to be used where it is liable to be subject to direct water spray...

Страница 3: ...should be inspected and cleaned to ensure there is no build up of dirt or other deposits on the impeller or the motor Caution do not dislodge any balance weights which may be fitted to the impeller If...

Страница 4: ...UTPUT L2 L3 TK TK FAN 2 OUTPUT N L1 U2 N U1 L U2 N E TK TK Fig 2 ATQ ACOUSTIC SINGLE PHASE FAN WIRING DETAILS STOCK REFERENCE NUMBERS ATQ 100 12C ATQ 125 12C ATQ 150 12C ATQ 160 12C ATQ 200 12C ATQ 25...

Страница 5: ...7 103 14 105 103 14 103 1 Phase Auto Transformer Speed Controller L N L N Fuse L1 L2 N1 E E Fig 3 ATQ ACOUSTIC SINGLE PHASE FAN AND AN AUTO TRANSFORMER WIRING DETAILS STOCK REFERENCE NUMBERS ATQ 100 1...

Страница 6: ...4 to 96 must be REMOVED 240 Volt D O L Starter A suitable sized overload relay must be fitted to provide motor protection N B Links between terminals 1 to 95 3 to 6 5 to A2 and 23 to 96 must be fitted...

Страница 7: ...provide motor protection E A1 23 95 N L2 L3 L2 L1 N TK TK L3 E A2 24 5 96 6 1 3 2 4 23 A1 95 24 A2 96 240 Volt D O L Starter A suitable sized overload relay must be fitted to provide motor protection...

Страница 8: ...the United Kingdom contact your local supplier Vent Axia guarantees its products for two years from the date of purchase against faulty material or workmanship In the event of any part being found to...

Отзывы: