background image

Page 3

JPH/C1 1213A

36"

30"

Installation Details

JPH/C1

1)  Read all instructions thoroughly before beginning installation. 

2)  When installing a JPH/C1 wall mount range hood, it is recommended that the bottom edge of the hood be located no 

more than 30" above the cooking surface for optimum performance.

3)  IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO STEP 4.

 

Consult the connection diagrams (on next page) for further details on exhaust outlet placement.

 

Install the duct(s) from the outside of the home to the ceiling over the exhaust outlet(s) on the hood. The end of the 

duct(s) should extend 1" below the ceiling.

 

Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back 

page of this instruction sheet.

 

Transition heights are as follows:

Single Blower (B100): 

6" round duct will connect directly to the top of the hood.

Dual Blower (B200): 

8" round duct will connect directly to the top of the hood.

Single and Dual Blower (B100 & B200):  6" round duct will connect directly to the top of the hood; 8” round will 

connect directly to the top of the hood. Optional 10" round combination 

transition (VP562, sold separately) is 17 1/2" tall.

Two Dual Blowers (Two B200s): 

Two 8” round ducts connect directly to the top of the hood. Optional 12” 

round combination transition (VP563, sold separately) is 16 1/2” tall.

Содержание JPH/C1 DESIGNER series

Страница 1: ...lling into wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhaustin...

Страница 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together...

Страница 3: ...he duct s should extend 1 below the ceiling Use duct tape to seal all joints A complete listing of available Vent A Hood ducting materials is provided on the back page of this instruction sheet Transi...

Страница 4: ...6 1 11 11 5 5 Wall Side 5 1 Electrical 2 8 Outlet Vent Holes 8 Outlet Centerline of Hood Installation Details Continued Connection Diagram 36 48 Widths 300 CFM B100 Single Blower Top View 600 CFM B200...

Страница 5: ...l Volts Amps Hz RPM CFM SP 0 0 Equivalent CFM CFM SP 0 1 CFM SP 0 2 CFM SP 0 3 Minimum Round Duct Size Sones B100 Single 115 1 5 60 1550 300 450 273 245 225 6 28 in 2 5 4 B200 Dual 115 2 9 60 1550 600...

Страница 6: ...previously removed from the strip in Step 10 into the pilot holes drilled in Step 12 SKIP STEP 14 PROCEED DIRECTLY TO STEP 15 14 If applicable install the transition on the insides of the exhaust col...

Страница 7: ...23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXI...

Отзывы: