Vent-a-Hood Euroline Скачать руководство пользователя страница 4

Page 4

(Rev. 02/08)

L113

Centerline

Of Hood

5" x 16"

Exhaust

Opening

8" Transition

Opening

Centerline

Of Hood

Vent Holes

Electrical

7 ¾"

12" Transition
Opening 2 ¼”

Above Top of

Hood

8” Blower

Outlets

Centerline

of Hood

Centerline

of Hood

Vent Holes

Electrical (2)

7 ¾”

10 ½”

9"

16"

5"

8" Round

8" Round

2 ¼”

18”

18"

12" Round

12" Round

11 ¼"

8" Round

8" Round

8" Round

Model

Volts

Amps

RPM

CFM

[email protected]

Equivalent CFM

CFM

[email protected]

CFM

[email protected]

CFM

[email protected]

Minimum Round

Duct Size

Square

Inches

#

T200 Island Dual

T400 Island Cluster

115

115

3.4

6.8

1550

1550

600

1200

900

1800

572

1144

540

1080

480

960

8” (or equivalent)

12” (or equivalent)

50

113

Note: Add 0.5 amp for each halogen light.
Because the Magic Lung   uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung   blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently 
than other than other filtration systems. When comparing the Magic Lung    with other blower units made by other manufacturers, use the “Equivalent CFM”.

*

TM

TM

TM

*
#

Installation Details Continued

6) Remove the blower shields (A) by loosening the two brass screws on the bottom of the shield. Gently close the back

draft dampers  from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (B) (one on
each side of the housing).  The housings should be pulled forward and gently “tipped” to clear the blower wheels and
then out of the hood.

Warning:  Make sure power is off and locked at the service disconnecting

means on the service panel during installation.

Connection Diagram (48”- 66” Widths)

Connection Diagram (36”- 48” Widths)

600 CFM T200 Dual Blower

(Top View)

1200 CFM T400 Dual Blowers

(Top View)

7) Remove the blower deck assembly by removing the 12 screws around the blower mounting plate. Unplug the electrical

connector(s) and set the blower assembly aside, taking care not to damage the blower wheels.

8) Install an appropriate 1/2” UL listed electrical wire clamp through the electrical strap(s) on top of the hood deck. Install

electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection diagrams
(above) for further details on electrical placement. Support the hood beneath the location where it will hang and feed
the electrical wire(s) into the wire clamp(s). Tighten the wire clamp(s).

Transition Installed

(Side View)

VP565 Standard Transition

(Included)

VP564 Standard Transition

(Included)

Transition Installed

(Side View)

Содержание Euroline

Страница 1: ...d lock the service disconnecting means to prevent power from being switched on accidentally during installation B When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to pr...

Страница 2: ...ngled turns Instead use smooth gradual turns such as adjustable elbows or 45 degree angled turns For duct runs over 20 feet increase the duct diameter by one inch for every ten feet of duct A 90 degree elbow is equal to 5 feet of duct Using Vent A Hood roof jacks or wall louvers back page will ensure proper efficiency Airflow must not be restricted at the end of the duct run Do not use screen wire...

Страница 3: ...he duct cover to the load bearing framework in the ceiling using appropriate hardware through the four inside corner mounting flanges on the top of the duct cover 4 Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus 1 This will allow the transition to engage 1 inside of the duct Consult the connection diagrams on next page for...

Страница 4: ...o brass screws on the bottom of the shield Gently close the back draft dampers from the top side of the hood To remove the blower housings unsnap the suitcase latches B one on each side of the housing The housings should be pulled forward and gently tipped to clear the blower wheels and then out of the hood Warning Make sure power is off and locked at the service disconnecting means on the service...

Страница 5: ...and seal with duct tape The transition must fit inside the exhaust collar on the blower deck assembly Reconnect the electrical connector s For assemblies with two connectors connect the right harness to the front connector and the left harness to the back connector While taking care to properly align the duct connection between the transition and the duct in the ceiling reinstall the blower deck a...

Страница 6: ...2 3 x 10 BACK VENT ELBOW MODEL DIM VP559 3 x 10 4 10 14 3 3 MULTI BLOWER TRANSITION MODEL DIM VP562 VP563 6 8 to 10 8 8 to 12 VP562 17 VP563 16 10 12 VP562 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Ro...