background image

HEAT/COOL DIFFERENTIAL - The Heat and Cool setpoints will not be 
    allowed to come any closer to each other than the value set in Advanced 
    Setup 

step #7, on page 13

.  This minimum difference is enforced during 

    Auto-changeover and Program On operation.

    

Note:

  To increase the spread between the heating and cooling setpoints, 

    press the MODE button until only the heat setpoint is displayed; adjust to 
    the desired setpoint.  Press the MODE button until only the cool setpoint 
    is displayed; adjust to the desired setpoint.  Press the MODE button again 
    to enter the Auto-changeover mode where both the heat and cool 
    setpoints are displayed.

         
        

About Advanced Features & Operation

WARNING: This will reset all Time Period and Advanced Programming to 
the  default  settings.   Any  information  entered  prior  to  this  reset  will  be 
permanently lost.

FACTORY DEFAULTS - 
    settings back to the factory default settings, follow the instructions below.  

If, for any reason, you desire to return all the stored

After all of the icons appear, release 
the MODE and 
DOWN buttons.  
Then press and 
hold the FAN 
button for 5 seconds.

After the letters 

Fd

 appear on the 

display (Factory 
Default), release 
the FAN button.  
Press the MODE
button 

twice

 to return to normal 

operation.  Two dashes will appear
momentarily as the display resets.

FAN

Press

Press

MODE

MEMORY BACKUP - In the event of a power loss, the thermostat will retain 
    the stored program settings without external power or batteries.
       

PROGRAMMABLE FAN - 
    and the fan will run for the number of minutes selected in step #10 
    on page 14.  

This timer will start the fan at the top of each hour;

Page 17

Press 

button.

While holding the 
MODE button, 
press and hold 
the DOWN button 
for 5 seconds.  
All of the icons will appear on 
the display.

and hold the MODE 

Place the 
thermostat in 
the OFF mode.

Press

MODE

Press

MODE

88

88

H

EAT

C

OOL

OFF

AUTO

Fan On

Program

Locked

Setup

On

o

o

Am

Pm

I8 88

88

:

Day

Night

Evening

Morning

SuMTuWThFSa

OFF

Pm

I2 00

70

:

Su

OFF

Pm

I2 00

70

:

Su

Содержание T1100RF

Страница 1: ...7 Day Programmable 4 Settings Day Auto Changeover 5 minute Built In Compressor Protection Self Prompting Programming w Copy Full Electronic Display Either F or C Back Lit Display Keypad Lockout Large...

Страница 2: ...se undesired operation C c F T1100RF FCC ID MUH T10013 CAUTION Follow Installation Instructions carefully DISCONNECT POWER TO THE HEATER AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLI...

Страница 3: ...E 67 70 HEAT COOL AUTO o o Am 6 03 68 Su Front Panel Liquid Crystal Display with Thermoglow Up Down Buttons Mode Button Fan Button Transmission Indicator Blinking Green Communicating with the Receiver...

Страница 4: ...es the system will automatically changeover between heat and cool modes as the temperature varies PROGRAM ON Indicates the time period program is enabled to run OFF Indicates heating and cooling are t...

Страница 5: ...s in the setup mode Fan On icon Page 7 Indicates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or cool Locked icon Page 18 Indicat...

Страница 6: ...te one or two stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section The thermostat is not prepr...

Страница 7: ...nly The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room Cooling Only OFF indicates both heating and air conditioning systems are t...

Страница 8: ...L MODE Pressing the UP or DOWN button in Heat or Cool mode will adjust only the heat or cool set temperature 76 COOL o Pm 12 00 70 M buttons Adjust the desired set temperature with the Selecting Your...

Страница 9: ...OL o o Am 6 00 Morning M Use the Programming Worksheet on the back cover to help with this section Press the MODE button While holding MODE press the UP button for two seconds to enter time period pro...

Страница 10: ...COOL o Pm 6 00 M Start Pm 6 00 Evening M Day 62 85 HEAT COOL o o Am 8 00 M Adjust the start time for Evening Adjust the start time for Day Adjust the cooling setpoint for Evening Adjust the heating se...

Страница 11: ...78 HEAT COOL o o Night Night 82 COOL o Pm I0 00 M 62 82 HEAT COOL o o I0 00 M Unit 1 only Programming a Daily Schedule Adjust the start time for Night Adjust the heating setpoint for Evening Adjust t...

Страница 12: ...n or each time this routine will repeat If No is selected as in previous steps flashing prompts for input will appear for the four time periods for the next day After programming for all seven days is...

Страница 13: ...p M I Setup Am I2 00 Yes No MODE FAN MODE Press the MODE button and release Immediately press the MODE button again While holding the MODE button press the FAN button When this screen appears I Setup...

Страница 14: ...tat is used each will need a different Unit ID number cy 8 Setup 6 5 Setup I 4 Setup o 6 Setup 2 7 HEAT COOL Setup 2 Note Available only on Unit ID 1 Adjust the deadband for the 1st stage 1 6 1 4 0 63...

Страница 15: ...acklight operation ON Light continuously OFF Light for 8 seconds after a button press Adjust the program mable fan timer 0 60 minutes 0 00 off After programming is complete press the MODE and FAN butt...

Страница 16: ...adaptor is used to power the thermostat Advanced Setup Advanced Setup Table Step Description Range Factory Default 1 2 3 4 5 6 7 8 9 10 11 Time of Day Day of the Week Zoning System House Code Unit ID...

Страница 17: ...d Stage turn on 1st Stage turn on 2nd Stage turn on Heating Cooling TEMPERATURE DECREASE INCREASE non adj 2 non adj 2 About Advanced Features Operation Press button While holding the MODE button press...

Страница 18: ...ngs follow the instructions below If for any reason you desire to return all the stored After all of the icons appear release the MODE and DOWN buttons Then press and hold the FAN button for 5 seconds...

Страница 19: ...00 70 W MODE Press all three buttons in the order outlined above for keypad lockout BATTERY ELIMINATOR optional accessory t supply adaptor is used to power the thermostat and eliminate the need for r...

Страница 20: ...ate with one hand while pulling on the top corner of the thermostat with your other hand Then turn the thermostat over to remove the batteries from the holder and replace with AA Lithium batteries You...

Страница 21: ...OEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TI...

Страница 22: ...py Thu Fri No Yes S U N D A Y Morning Day Evening Night Copy Sat Sun No Yes Copy Wed Thu W E N E S D D A Y T U R H S D A Y Morning Morning Day Day Evening Evening Night Night No Yes DAY PERIOD HEAT ST...

Отзывы: