Main Menu Buttons -
Settings
Heat Pump Settings
Installation Settings
HP Lockout Outdoor Temp
(65
˚
)
Heat Pump will not run below this temp. (0˚ - 75˚ F)
Aux Heat Lockout - DISABLED
Aux Heat Lockout - ENABLED
Turns on Aux Heat Lockout.
Aux Heat Lockout Temp
(65
˚
)
Aux Heat will not run above this temp. (0˚ - 75˚ F) GAS/EL or HP dip
switch must be set for HP and GAS or ELEC dip switch must be set for ELEC.
Heat Pump Lockout - DISABLED
Heat Pump Lockout - ENABLED
Turns on Heat Pump Lockout.
(Only available
when dip switch
is set for Heat
Pump operation.)
(Continued)
Sensor Settings
Control Sensor
(thermostat)
When a remote sensor is connected to the thermostat, the user may choose
which sensor source is used to measure room temperature.
Wired Sensor Use
(remote)
The wired sensor may be used as follows:
Calibrate Sensors
(0
˚
)
The thermostat and wired sensor may be calibrated -7˚ to +7˚ F.
Thermostat sensor only
Wired Sensor only
Average remote/thermostat
Outdoor sensor
Remote Sensor
Supply Sensor
Return Sensor
For Lockout
Temperatures:
A local outdoor
sensor connected to
the thermostat is
required.
Skyport supplied
outdoor temperature
will not work in place
of a local sensor.