Electric TV Lift, TS700C & TS1000C
12
b. Orientation of TV-Lift
The
Jumper Rev
is default =
set,
for TV-Lifts mounted upside up. For upside down
the
Jumper Rev
has to be moved to
open.
c. Anti-squeeze on/off (autostop with auto reverse)
The
Jumper Off
is default =
set
, which means that the anti-squeeze function is off.
Move the
Jumper Off
to
open
to activate the function. The system will work in both
directions when activated *.
d. Sensitivity of Anti-squeeze
The sensitivity of the function is possible to select.
Jumper Aux
=
set
(default setting) will give a low sensitivity *.
Jumper Aux
=
open
will give a high sensitivity *.
The default low sensitivity setting is for higher loads. If the loading is low then it will be necessary to
select the high sensitivity setting to get the best function of the system.
‘Load' includes the effect of
any type of cabinet lid. The lift installer can test both settings but generally speaking load above 20-
30kg may require the default low sensitivity setting.
Anti-squeeze safety precaution*
This feature will stop the TV-Lift in both directions and it will reverse approximately 3cm automatically
if a sudden conflict with an obstacle happens. The sensitivity is different in up and down directions.
With the lift installed upright and "Jumper Aux = set”, then in the event of a downward collision the lift
will squeeze with a pressure equal to the weight of the TV that is fitted to the lift plus approximately 3-
5kg before the Anti-squeeze system will operate. For the upward direction the system will squeeze
with a pressure of less than 3-5kg before operating.
If the lift is installed upside down ensure Jumper Rev is set correctly and the above will still apply.
The feature will not work in the following situations.
If the collision and load impact happens in a gradual way.
If the collision happens within 1 sec after the up or down button has been activated.
e. Remote emitter function
The
Jumper M/L
is default =
set
and the buttons on the emitter only need to be
pushed once for operation. If moved to
open
then the emitter button will need to be
held down during the operation of the lift, ie..for use where a higher level of safety
may be required.
Using multiple TS700C/1000C combined
With the optional ‘sync control box’ it is possible to synchronize two or more lifts up to a
maximum of six. eg.. for extra wide or extra heavy screens. See Venset.com